Emerson 1F92 manual Heat Pump Terminal Outputs

Page 11

HEAT PUMP TERMINAL OUTPUTS

Refer to equipment manufacturers’ instructions for specific system wiring information.

You can configure the thermostat for use with the following heat pump system types:

HEAT PUMP TYPE 1. Single- stage compressor system; gas or electric backup.

HEAT PUMP TYPE 2. Multi-stage or two-compressor system; gas or electric backup.

HEAT PUMP TYPE 3. System requiring separate signals for heat (W1, W2) and cool (Y1); gas or electric backup.

This thermostat is designed to operate a single-transformer system. If you have a two-transformer system, cut and tape off one transformer. If transformer safety circuits are in only one of the systems, remove the transformer of the system with NO safety circuits. If required, replace remaining trans- former with a 75VA Class II transformer. After disconnecting one transformer, the two commons must be jumpered together.

Use the terminal output information on the next page to help you wire the thermostat properly for your heat pump system type. After wiring, see CONFIGURATION section for proper thermostat configuration.

9

Installation

Image 11
Contents Series Easy, Menu-Driven Set-Up Programming Introduction Thermostat Buttons OrientationDisplay Thermal Data InstallationSpecifications Electrical DataPrecautions Attach Base to Wall Installation Remove OLD Thermostat Thermostat base and terminals Configuring ProgrammingThermostat Terminals Upper MULTI-STAGE Terminal OutputsHeat Pump Terminal Outputs Malfunction Light Not Used Thermostat Terminals Lower E2/P Switch Configuration Switches Reset SwitchEntering the Configuration Menus Installer ConfigurationSET Cycle HEAT, COOL, AUX Anticipation MULTI-STAGE/HEAT Pump ModeHeat Pump COMPRES- SOR Configuration Electric Heat FAN ConfigurationHeating Cooling Comments Installer TableHeat Pump 1 Pump Fossil Fuel KIT Alternative Programmable Cool FAN-OFF and FAN-ON DelayProgrammable Heat FAN-OFF Delay Compressor Lockout Economizer FeatureUntil FAN Auto FAN OperationHeating System MULTI-STAGE/HEAT Pump Auxiliary Operation Test Cooling SystemResetting Thermostat Configuration and Programming Troubleshooting Reset ButtonConfiguration User Menu Keypad Lockout Menu access from User Menu To Set the Day ProgrammingProgrammed Operation Planning Your Program Entering Your Program To Set the ClockFAN Day Sample Program Schedule Shows factory programming Day Personal Program Schedule Selectable Energy Management Recovery EMR FeaturesAdjustable Temperature Display Cool Fast Fahrenheit or Celsius Tem- perature DisplaySingle Period Fan Control Heat FastKeypad Lockout Traditional Features Automatic ChangeoverFactory Preprogrammed Times and Temperatures Activate RUN PRG by Telephone Compressor Run TimeProgrammable Fan Control Compressor Short-Cycle ProtectionSystem and Thermostat Diagnostics Air Filter Change-Out IndicatorIndefinite Program Hold Temporary Program OverrideDaylight Savings Time Button Programmable Vacation Time/ Temperature OperationArm Chair Programming Thermostat Startup After Total Power LossLarge Lighted Liquid Crystal Display LCD Second Stage Time Delay Index FeaturesPage Page Part no -6422C