Miller Electric 12VS manual Display Board PC20 DIP Switch Settings

Page 24

4-10. Display Board (PC20) DIP Switch Settings

1

2

3

4

5

DIP Switch Settings:

Display Hold ON

Displays will hold their last value for five seconds after the trigger is re- leased. After the hold times out, the Voltage Display will show open circuit voltage. If the Wire Speed / Amps Display is set to display Amps, the amperage value will hold, after the hold times out, preset Wire Speed will be displayed.

 

 

 

 

 

Display Hold OFF

 

 

 

 

 

Displays will not hold values. Immedi-

1

2

3

4

5

ately, when the trigger is released,

the Voltage Display will show open

 

 

 

 

 

 

 

 

 

 

circuit voltage. The Wire Speed /

 

 

 

 

 

Amps Display will display preset Wire

 

 

 

 

 

Speed when the trigger is released.

1

 

2

 

3

 

4

 

5

DIP Switch Factory Settings

Indicates Switch does not Affect This Function

1

2

3

4

5

1

2

3

4

5

Do Not Display Amperage

Wire Speed / Amps Display will dis- play only Wire Speed.

Display Amperage

Wire Speed / Amps Display will dis- play Amps while welding and Wire Speed while not welding. If the hold function is enabled, Amps will be dis- played during hold also.

.DIP switch is located

behind front panel as shown.

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

1

2

3

4

5

Ref. 804 006-A

Wire Speed - Inches Per Minute

Displays Wire Speed in Inches per Minute.

Wire Speed - Meters Per Minute

Displays Wire Speed in Meters per Minute.

Information OFF

Information is not displayed.

Information ON

With switch in ON position, at feeder power up, feeder will display various sets of information. Each set of infor- mation will be displayed for three sec- onds.

Display Board (PC20) Software Part Number −

Top display will show the first three digits, bottom display will show last three digits of the Display board (PC20) software revision level.

Motor Board (PC1) Software Part Number −

Top display will show the first three digits, bottom display will show last three digits, of the Motor board (PC1) software revision level.

Accumulated Weld Time −

This is the time the feeder has actual- ly been used for welding. This infor- mation will be displayed in two halves. First being years and days, second in hours and minutes. Top display will show years/hours, bot- tom display will show days/minutes.

OM-1500-19 Page 20

Image 24
Contents OM-1500-19 219 185P ProcessesDescription File MIG GmawFrom Miller to You Table of Contents Directives StandardsDecstat1/07 Symbol Usage Arc Welding HazardsElectric Shock can kill HOT Parts can cause severe burnsFumes and Gases can be hazardous ARC Rays can burn eyes and skinWelding can cause fire or explosion Flying Metal or Dirt can injure eyesWelding Wire can cause injury Fire or Explosion hazardFalling Unit can cause injury Moving Parts can cause injuryPrincipal Safety Standards California Proposition 65 WarningsEMF Information About Implanted Medical DevicesSymboles utilisés UNE Décharge Électrique peut entraîner la mortDES Pièces Chaudes peuvent provoquer des brûlures graves LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in cendie ou une explosion LE Bruit peut endommager l’ouïe LES Bouteilles peuvent exploser si elles sont endommagéesRisque D’INCENDIE OU D’EXPLO- Sion LA Chute DE L’APPAREIL peut blesserProposition californienne 65 Avertissements LES Fils DE Soudage peuvent provoquer des blessuresLE Soudage À L’ARC risque de provoquer des interférences Principales normes de sécurité Information EMFEn ce qui concerne les implants médicaux OM-1500-19 Disconnect input plug or power before working on machine − DefinitionsKeep your head out of the fumes Manufacturer’s Rating Label For CE Products Weee Label For Products Sold Within The EUSymbols And Definitions − Installation SpecificationsPower WeightEquipment Connection Diagram Installing And Aligning Wire Guide And Drive Rolls Installing Wire Guide And Drive RollsAligning Wire Guide And Drive Rolls Cleaning Drive RollsConnecting Welding Gun And Voltage Sensing Clamp Connecting Shielding GasConnecting Weld Cable Weld Cable SizesInstalling And Threading Welding Wire 150 mm Pull and hold wire cut off end Tighten ClockwiseInstalling Wire And Adjusting Hub Tension Threading Welding WireDisplay Board PC20 DIP Switch Settings − Operation Controls With MetersControls Without Meters Gun Consumables Information Wire Speed Control Settings − Maintenance & Troubleshooting Overload Protection And Thermostat ProtectionThermostat Protection Troubleshooting Diagnostics Error IndicationsCommunication Error Motor Overload ErrorOM-1500-19 − Electrical Diagram Circuit Diagram For Wire Feeder− Parts List 19 20 51 68Diagram Part Marking Description Quantity 207 Front Panel Assembly without Meters Front Panel Assembly with Meters Drive Roll & Wire Guide Kits 2 Drive Roll Start Your Professional Welding Career Now SOCKET/WRENCH Selection Table Standard Metric Material Thickness Gauge Service Your distributor also givesSupport To locate a Distributor or Service Agency visit Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Your distributor and/or equipment manufacturer’s