Miller Electric Big Blue 452P, Big Blue 302P Servicing Air Cleaner, Do not run engine without air

Page 50

9-3. Servicing Air Cleaner

 

 

 

 

 

Y Stop engine.

 

 

 

 

 

Y Do not run engine without air

1

2

3

4

 

cleaner or with dirty element. En-

 

gine damage caused by using a

 

 

 

 

 

 

 

 

 

 

damaged element is not covered

 

 

 

 

 

by the warranty.

 

 

 

 

 

. The air cleaner primary element can

 

 

 

 

 

be cleaned but the dirt holding capac-

 

 

 

 

 

ity of the filter is reduced with each

 

 

 

 

 

cleaning. The chance of dirt reaching

 

 

 

 

 

the clean side of the filter while clean-

 

Optional

 

 

 

ing and the possibility of filter damage

 

 

 

 

makes cleaning a risk. Consider the

 

 

 

 

 

 

 

 

 

5

risk of unwarrantable equipment

 

 

 

 

damage when determining whether

 

 

 

 

 

 

 

 

 

 

to clean or replace the primary ele-

 

 

 

 

 

ment.

 

 

 

 

 

If you decide to clean the primary ele-

 

 

 

 

 

ment, we strongly recommend instal-

 

 

 

 

 

ling an optional safety element to pro-

 

 

 

 

 

vide additional engine protection.

 

 

 

 

 

Never clean a safety element. Re-

 

 

 

 

 

place the safety element after servic-

 

 

 

 

 

ing the primary element three times.

Keep nozzle 2 in (51 mm) from element.

Clean or replace primary element if dirty (see note above before cleaning). Re- place primary element if damaged. Re- place primary element yearly or after six cleanings.

 

 

1

Housing

 

 

2

Safety Element (Optional)

 

 

3

Primary Element

 

 

4

Dust Cap

 

 

5

Dust Ejector

 

 

To clean air filter:

 

 

Wipe off cap and housing. Remove cap

 

 

and dump out dust. Remove element(s).

 

 

Wipe dust from inside cap and housing

Blow

Inspect

with damp cloth. Reinstall safety element

(if present). Reinstall cap.

 

 

Y Do not clean housing with air hose.

Clean primary element with compressed air only.

Air pressure must not exceed 100 psi (690 kPa). Use 1/8 in (3 mm) nozzle and keep nozzle at least 2 in (51 mm) from inside of element. Replace primary ele- ment if it has holes or damaged gaskets.

Reinstall primary element and cap (dust ejector down).

aircleaner1 9/00 − ST-153 929-B / ST-153 585 / Ref. S-0698-B / Ref. 201 841

OM-496 Page 44

Return To Table Of Contents

Image 50
Contents Description OM-496Processes From Miller to You Table of Contents 11-3 11-111-2 Deccon1 11/02 DirectivesStandards Sound Level Information Deccon1 5/98Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards EMF Information Principal Safety StandardsCalifornia Proposition 65 Warnings Radiation can cause interferenceUN Choc Électrique peut tuer Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation LES Fumées ET LES GAZ peuvent être dangereuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux LE Bruit peut affecter l’ouïeLA Chaleur DU Moteur peut pro- voquer un incendie ’EXPLOSION DE LA Batterie peutDES Organes Mobiles peuvent provoquer des blessures ’AIR Comprimé peut provoque r des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiques− Definitions + − Starting InstructionsCan cause severe burns. Do Are possible hazards asHot muffler and exhaust pipes EngineReturn To Table Of Contents Std Manufacturer’s Rating Labels For CE Products− 50 h Std CC Models CC/CV ModelsSymbols And Definitions Dimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Volt-Ampere Curves For CC Models TIG Mode Stick ModeMIG Mode Volt-Ampere Curves For CC/CV ModelsFuel Consumption Duty Cycle And Overheating12 kVA/kW Single-Phase AC Output No Weld Load AC Generator Power CurveOptional Three-Phase Generator Curves 15 kVA/kW Three-Phase AC Output No Weld LoadLocation Grounding − InstallationInstalling Welding Generator See Sections 5-2And Airflow ClearanceUsing Lifting Eye Work like a ProMounting Surface Mounting Welding GeneratorSupporting The Unit To Bolt Unit In PlaceInstalling Exhaust Pipe Stop engine and let coolRead and follow all instruc Activating The Dry Charge Battery If ApplicableWhen electrolyte is low, add ChargerConnect Negative − Cable Last Connecting The BatteryReinstall cover after connecting battery Coolant Recovery Tank Engine Prestart ChecksConnecting To Weld Output Terminals Selecting Weld Cable SizesRef 862-A / 048 720-K / 802 Connecting To Remote 14 Receptacle RC14 On CC/CV Models Socket− Operating Welding Generator − CC Models Front Panel Controls For CC Models See SectionDo not switch under load To Start Do not use ether. Using ether voids warrantyEngine Indicator Lights Engine Starting ControlsExample Combination Remote Amperage Control Stick Remote Amperage Control On CC Models OptionalWeld Control/Arc Condition Information Label Set weld controls as shown toReturn To Table Of Contents − Operating Welding Generator − CC/CV Models Front Panel Controls For CC/CV Models See SectionUse switch to select weld amperage range Voltage/Amperage Adjust Switch And Remote 14 ReceptacleProcess/Contactor Switch On CC/CV Models Process/Contactor Switch SettingsRemote Voltage/Amperage Control On CC/CV Models Optional Example Combination Remote Amperage Control TIGAt least once a month, run en − Operating Auxiliary EquipmentVolt And 240 Volt Receptacles Open, contact Factory AuthoClose panel opening if no connections are made to generator Three-Phase Power ConnectionRear Of Panel Circuit Breaker CB2 Circuit Breaker CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 For Non-CE Products − Maintenance & Troubleshooting Maintenance Labels Every 50 h Routine MaintenanceEvery 8 h Every 100 hEvery 2000 h Clean/Set InjectorsEvery 1000 h Change FuelTo clean air filter Servicing Air CleanerBy the warranty Do not clean housing with air hoseInspecting And Cleaning Optional Spark Arrestor Muffler Reinstall cleanout plug Tools NeededDo not set engine speed higher than specified Adjusting Engine Speed On Standard ModelsMaximum Close door Tools Needed 10 mmEngine Speed No Load Idle Speed AdjustmentWeld/Power Speed Adjustment Rpm max 61.6 Hz 1250 rpm 41.6 HzServicing Fuel And Lubrication Systems Overload Protection Correct the cause of the shut Diagnosing Causes Of Engine Fault ShutdownsDiagnostic Checks While Running Down before operatingTroubleshooting Welding − CC ModelsWelding − CC/CV Models Engine Standard Generator PowerOptional Three-Phase Generator Power CC/CV Models Only Temperature is too high see Sections 5-7and Wiring harness and componentsShutdown switch is released Out Air in fuel system. See engine manualReturn To Table Of Contents − Electrical Diagrams Circuit Diagram For CC Welding Generator215 296-B Circuit Diagram For CC/CV Welding Generator 215 297-B Ment damage may occur − RUN-IN ProcedureWetstacking Stop engine Do not touch hot exhaust Run-In Procedure Using Load BankProcedure at less than From flammables Do not PerformFrom flammables Run-In Procedure Using Resistance GridBank/grid Do not perform run-inSelecting Equipment − Generator Power GuidelinesHas this symbol Grounding Generator To Truck Or Trailer FrameEarth ground if supplying Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Use ground device as stated in electrical codesIndustrial Motors Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsSingle-Phase Induction Motor Starting Requirements Power Required To Start MotorHow Much Power Can Generator Supply? KVA/HP x HP xTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes− Parts List 109 111 -4 or118 85 FigDia Part Mkgs Description Quantity 209 Figures 13-2 Control Box Assembly − CC Models PLG3 Control Box Assembly − CC/CV Models PC7 195 Panel, Front w/Components − CC Models RC13 032 Panel, Front w/Components − CC/CV Models 41 40Panel, Front w/Components − CC/CV Models -1Item PC4, PC5 189 Generator Generator -1Item602 SCREW, .312−18x .75 hexwhd.66d stl pld slffmg tap−rw 601 Main Rectifier Assembly Page Page Support ServiceYour distributor also gives Your distributor and/or equipment manufacturer’s Miller Electric Mfg. CoFor assistance in filing or settling claims, contact Transportation Department