Miller Electric Big Blue 452P, Big Blue 302P manual Engine Hazards

Page 8

WELDING can cause fire or explosion.

Welding on closed containers, such as tanks, drums, or pipes, can cause them to blow up. Sparks can fly off from the welding arc. The flying sparks, hot workpiece, and hot

equipment can cause fires and burns. Accidental contact of electrode to metal objects can cause sparks, explosion, overheating, or fire. Check and be sure the area is safe before doing any welding.

DProtect yourself and others from flying sparks and hot metal.

DDo not weld where flying sparks can strike flammable material.

DRemove all flammables within 35 ft (10.7 m) of the welding arc. If this is not possible, tightly cover them with approved covers.

DBe alert that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas.

DWatch for fire, and keep a fire extinguisher nearby.

DBe aware that welding on a ceiling, floor, bulkhead, or partition can cause fire on the hidden side.

DDo not weld on closed containers such as tanks, drums, or pipes, unless they are properly prepared according to AWS F4.1 (see Safety Standards).

DConnect work cable to the work as close to the welding area as practical to prevent welding current from traveling long, possibly unknown paths and causing electric shock and fire hazards.

DDo not use welder to thaw frozen pipes.

DRemove stick electrode from holder or cut off welding wire at contact tip when not in use.

DWear oil-free protective garments such as leather gloves, heavy shirt, cuf- fless trousers, high shoes, and a cap.

DRemove any combustibles, such as a butane lighter or matches, from your person before doing any welding.

DFollow requirements in OSHA 1910.252 (a) (2) (iv) and NFPA 51B for hot work and have a fire watcher and extinguisher nearby.

FLYING METAL can injure eyes.

DWelding, chipping, wire brushing, and grinding cause sparks and flying metal. As welds cool, they can throw off slag.

DWear approved safety glasses with side shields even under your welding helmet.

HOT PARTS can cause severe burns.

DAllow cooling period before maintaining.

D Wear protective gloves and clothing when working on a hot engine.

DDo not touch hot engine parts or just-welded parts bare-handed.

NOISE can damage hearing.

Noise from some processes or equipment can damage hearing.

DWear approved ear protection if noise level is high.

MAGNETIC FIELDS can affect pacemakers.

D Pacemaker wearers keep away.

D Wearers should consult their doctor before going near arc welding, gouging, or spot welding opera- tions.

CYLINDERS can explode if damaged.

Shielding gas cylinders contain gas under high pressure. If damaged, a cylinder can explode. Since gas cylinders are normally part of the welding process, be sure to treat them carefully.

DProtect compressed gas cylinders from excessive heat, mechanical shocks, slag, open flames, sparks, and arcs.

DInstall cylinders in an upright position by securing to a stationary support or cylinder rack to prevent falling or tipping.

DKeep cylinders away from any welding or other electrical circuits.

DNever drape a welding torch over a gas cylinder.

DNever allow a welding electrode to touch any cylinder.

DNever weld on a pressurized cylinder — explosion will result.

DUse only correct shielding gas cylinders, regulators, hoses, and fittings de- signed for the specific application; maintain them and associated parts in good condition.

DTurn face away from valve outlet when opening cylinder valve.

DKeep protective cap in place over valve except when cylinder is in use or connected for use.

DRead and follow instructions on compressed gas cylinders, associated equipment, and CGA publication P-1 listed in Safety Standards.

1-3. Engine Hazards

BATTERY EXPLOSION can BLIND.

DAlways wear a face shield, rubber gloves, and protec-

tive clothing when working on a battery.

D Stop engine before disconnecting or connecting bat- tery cables or servicing battery.

DDo not allow tools to cause sparks when working on a battery.

DDo not use welder to charge batteries or jump start vehicles.

DObserve correct polarity (+ and −) on batteries.

DDisconnect negative (−) cable first and connect it last.

FUEL can cause fire or explosion.

D Stop engine and let it cool off before checking or add- ing fuel.

DDo not add fuel while smoking or if unit is near any sparks or open flames.

DDo not overfill tank — allow room for fuel to expand.

DDo not spill fuel. If fuel is spilled, clean up before starting engine.

DDispose of rags in a fireproof container.

DAlways keep nozzle in contact with tank when fueling.

MOVING PARTS can cause injury.

D Keep away from fans, belts, and rotors.

D Keep all doors, panels, covers, and guards closed and securely in place.

DStop engine before installing or connecting unit.

DHave only qualified people remove guards or covers for maintenance and troubleshooting as necessary.

DTo prevent accidental starting during servicing, disconnect negative (−) battery cable from battery.

DKeep hands, hair, loose clothing, and tools away from moving parts.

DReinstall panels or guards and close doors when servicing is finished and before starting engine.

DBefore working on generator, remove spark plugs or injectors to keep engine from kicking back or starting.

DBlock flywheel so that it will not turn while working on generator compo- nents.

OM-496 Page 2

Return To Table Of Contents

Image 8
Contents Description OM-496Processes From Miller to You Table of Contents 11-3 11-111-2 Deccon1 11/02 Directives Standards Sound Level Information Deccon1 5/98Symbol Usage Arc Welding HazardsEngine Hazards Compressed Air Hazards Principal Safety Standards California Proposition 65 WarningsEMF Information Radiation can cause interferenceSignification des symboles − Consignes DE Sécurité − Lire Avant UtilisationUN Choc Électrique peut tuer LES Fumées ET LES GAZ peuvent être dangereuxLE Soudage peut provoquer un in- cendie ou une explosion DES Particules Volantes peuvent blesser les yeuxDES Pièces Chaudes peuvent provoquer des brûlures graves LE Bruit peut affecter l’ouïe’EXPLOSION DE LA Batterie peut DES Organes Mobiles peuvent provoquer des blessuresLA Chaleur DU Moteur peut pro- voquer un incendie ’AIR Comprimé peut provoque r des blessuresPrincipales normes de sécurité Information sur les champs électromagnétiques− Definitions + − Starting InstructionsAre possible hazards as Hot muffler and exhaust pipesCan cause severe burns. Do EngineReturn To Table Of Contents Manufacturer’s Rating Labels For CE Products − 50 h StdStd CC Models CC/CV ModelsSymbols And Definitions Dimensions, Weights, And Operating Angles − SpecificationsWeld, Power, And Engine Specifications Volt-Ampere Curves For CC Models Stick Mode MIG ModeTIG Mode Volt-Ampere Curves For CC/CV ModelsFuel Consumption Duty Cycle And OverheatingAC Generator Power Curve Optional Three-Phase Generator Curves12 kVA/kW Single-Phase AC Output No Weld Load 15 kVA/kW Three-Phase AC Output No Weld Load− Installation Installing Welding Generator See Sections 5-2AndLocation Grounding Airflow ClearanceUsing Lifting Eye Work like a ProMounting Welding Generator Supporting The UnitMounting Surface To Bolt Unit In PlaceInstalling Exhaust Pipe Stop engine and let coolActivating The Dry Charge Battery If Applicable When electrolyte is low, addRead and follow all instruc ChargerConnect Negative − Cable Last Connecting The BatteryReinstall cover after connecting battery Coolant Recovery Tank Engine Prestart ChecksConnecting To Weld Output Terminals Selecting Weld Cable SizesRef 862-A / 048 720-K / 802 Connecting To Remote 14 Receptacle RC14 On CC/CV Models Socket− Operating Welding Generator − CC Models Front Panel Controls For CC Models See SectionTo Start Do not use ether. Using ether voids warranty Engine Indicator LightsDo not switch under load Engine Starting ControlsRemote Amperage Control On CC Models Optional Weld Control/Arc Condition Information LabelExample Combination Remote Amperage Control Stick Set weld controls as shown toReturn To Table Of Contents − Operating Welding Generator − CC/CV Models Front Panel Controls For CC/CV Models See SectionUse switch to select weld amperage range Voltage/Amperage Adjust Switch And Remote 14 ReceptacleProcess/Contactor Switch On CC/CV Models Process/Contactor Switch SettingsRemote Voltage/Amperage Control On CC/CV Models Optional Example Combination Remote Amperage Control TIG− Operating Auxiliary Equipment Volt And 240 Volt ReceptaclesAt least once a month, run en Open, contact Factory AuthoClose panel opening if no connections are made to generator Three-Phase Power ConnectionRear Of Panel Circuit Breaker CB2 Circuit Breaker CB3 Optional Generator Power Receptacles240 V 15 a AC South African Receptacle RC1 For Non-CE Products − Maintenance & TroubleshootingMaintenance Labels Routine Maintenance Every 8 hEvery 50 h Every 100 hClean/Set Injectors Every 1000 hEvery 2000 h Change FuelServicing Air Cleaner By the warrantyTo clean air filter Do not clean housing with air hoseInspecting And Cleaning Optional Spark Arrestor Muffler Reinstall cleanout plug Tools NeededAdjusting Engine Speed On Standard Models MaximumDo not set engine speed higher than specified Close door Tools Needed 10 mmIdle Speed Adjustment Weld/Power Speed AdjustmentEngine Speed No Load Rpm max 61.6 Hz 1250 rpm 41.6 HzServicing Fuel And Lubrication Systems Overload Protection Diagnosing Causes Of Engine Fault Shutdowns Diagnostic Checks While RunningCorrect the cause of the shut Down before operatingTroubleshooting Welding − CC ModelsWelding − CC/CV Models Engine Standard Generator PowerOptional Three-Phase Generator Power CC/CV Models Only Wiring harness and components Shutdown switch is released OutTemperature is too high see Sections 5-7and Air in fuel system. See engine manualReturn To Table Of Contents − Electrical Diagrams Circuit Diagram For CC Welding Generator215 296-B Circuit Diagram For CC/CV Welding Generator 215 297-B Ment damage may occur − RUN-IN ProcedureWetstacking Run-In Procedure Using Load Bank Procedure at less thanStop engine Do not touch hot exhaust From flammables Do not PerformRun-In Procedure Using Resistance Grid Bank/gridFrom flammables Do not perform run-in− Generator Power Guidelines Has this symbolSelecting Equipment Grounding Generator To Truck Or Trailer FrameGrounding When Supplying Building Systems How Much Power Does Equipment Require?Earth ground if supplying Use ground device as stated in electrical codesApproximate Power Requirements For Industrial Motors Approximate Power Requirements For Farm/Home EquipmentIndustrial Motors Rating Starting Watts Running Watts Farm/Home Equipment Rating Starting Watts Running WattsApproximate Power Requirements For Contractor Equipment Contractor Rating Starting Watts Running WattsPower Required To Start Motor How Much Power Can Generator Supply?Single-Phase Induction Motor Starting Requirements KVA/HP x HP xTypical Connections To Supply Standby Power Selecting Extension Cord Use Shortest Cord Possible Current Load Watts Amperes− Parts List 109 111 -4 or118 85 FigDia Part Mkgs Description Quantity 209 Figures 13-2 Control Box Assembly − CC Models PLG3 Control Box Assembly − CC/CV Models PC7 195 Panel, Front w/Components − CC Models RC13 032 Panel, Front w/Components − CC/CV Models 41 40Panel, Front w/Components − CC/CV Models -1Item PC4, PC5 189 Generator Generator -1Item602 SCREW, .312−18x .75 hexwhd.66d stl pld slffmg tap−rw 601 Main Rectifier Assembly Page Page Support ServiceYour distributor also gives Miller Electric Mfg. Co For assistance in filing or settling claims, contactYour distributor and/or equipment manufacturer’s Transportation Department