Miller Electric 500DX R, OM-129 manual Troubleshooting, Welding

Page 39

7-11. Troubleshooting

A. Welding

Trouble

Remedy

 

 

No weld output.

Check position of Ampere Range switch.

 

 

 

Check position of optional polarity switch.

 

 

 

Disconnect equipment from auxiliary power receptacles during start-up.

 

 

 

Place A/V Control switch in Panel position, or place switch in Remote position and connect remote con-

 

trol to Remote A/V Control receptacle RC3 (see Sections 4-9and 5-1).

 

 

 

Check and secure connections to Remote A/V Control receptacle RC3 (see Section 4-9).

 

 

 

Place optional Output/Contactor Control switch in On position, or place switch in Remote position and

 

connect remote contactor to optional Remote 14 receptacle RC3 or terminal strip 2T (see Sections 4-10

 

and 4-11).

 

 

 

Have Factory Authorized Service Agent check brushes and slip rings, field excitation circuit, and

 

optional field current regulator board PC1.

 

 

Erratic weld output.

Check and tighten connections inside and outside unit.

 

 

 

Be sure connection to work piece is clean and tight.

 

 

 

Use dry, properly stored electrodes.

 

 

 

Remove excessive coils from weld cables.

 

 

 

Check Ampere Range switch connections and contacts.

 

 

High or low weld output.

Check engine speed, and adjust if necessary (see Section 7-5).

 

 

 

Check optional CC/CV switch position.

 

 

Low open-circuit voltage.

Check engine speed, and adjust if necessary (see Section 7-5).

 

 

 

Check optional CC/CV switch position.

 

 

 

Have Factory Authorized Service Agent check optional field current regulator board PC1 and CV

 

regulator board PC2.

 

 

Maximum weld output only in each

Have Factory Authorized Service Agent check Amperage/Voltage control R1, capacitor C8, diode D8,

ampere range.

integrated rectifier SR4, control relay CR2, and optional CV regulator board PC2.

 

 

Wire feeder does not work (models with

Reset circuit breaker CB3 and/or CB4 (see Section 7-10).

CV option).

 

 

 

 

Check connections to optional Remote 14 receptacle RC3 and terminal strip 2T (see Sections 4-10and

 

4-11).

 

 

 

Repair or replace wire feeder.

 

 

No amperage control (or voltage control

Place A/V Control switch in correct position.

on models with CV option).

 

 

 

 

Check connections to optional Remote 14 receptacle RC3 and terminal strip 2T (see Sections 4-10and

 

4-11).

 

 

 

Repair or replace remote control device.

 

 

 

Have Factory Authorized Service Agent check optional CV regulator board PC2.

 

 

Low CV weld output (models with CV

Set Ampere Range switch to highest range.

option).

 

 

 

Min or max CV weld output only (models

Check position of Amperage/voltage control and Amperage/Voltage Control switch.

with CV option).

 

 

 

OM-129 647 Page 35

Image 39
Contents OM-129 647W ProcessesDescription From Miller to You Table of Contents Page ARC Rays can burn eyes and skin Symbol UsageArc Welding Hazards Electric Shock can killEngine Hazards Engine Heat can cause fire Battery Explosion can BlindMoving Parts can cause injury Engine Exhaust Gases can killARC Welding can cause interference Principal Safety StandardsEMF Information Radiation can cause interferenceLES Fumées ET LES GAZ peuvent être dangereux Signification des symboles− Consignes DE Sécurité − Lire Avant Utilisation UN Choc Électrique peut tuerLE Bruit peut affecter l’ouïe LE Soudage peut provoquer un in- cendie ou une explosionDES Particules Volantes peuvent blesser les yeux DES Pièces Chaudes peuvent provoquer des brûlures gravesLA Chute DE L’APPAREIL peut blesser DES Organes Mobiles peuvent provoquer des blessures’EXPLOSION DE LA Batterie peut LA Chaleur DU Moteur peut pro- voquer un incendieConsignes relatives aux stimulateurs cardiaques Principales normes de sécuritéInformation sur les champs électromagnétiques LE Soudage À L’ARC risque de provoquer des interférences− Definitions − SpecificationsSymbols And Definitions Weld, Power, And Engine Specifications1898 lb 861 kg Engine End Dimensions, Weights, And Operating AnglesCurve shows typical fuel use under weld or power loads Fuel Consumption60% Duty Cycle At 500 Amperes Duty Cycle is Percentage AC Auxiliary PowerWarranty Minutes Welding Minutes Resting Duty Cycle And OverheatingCC/DC Standard CV/DC Models With CV Option Volt-Ampere CurvesOptional AC Power Plant Curves Location − InstallationInstalling Welding Generator Do Not Lift Unit From End Airflow ClearanceMaintain proper level Activating The Dry Charge BatteryWhen electrolyte is low, add ChargerTools Needed 1/2 Connecting The BatteryEngine Prestart Checks Connect Negative − Cable LastSelecting Weld Cable Sizes Connecting To Weld Output TerminalsInstalling Ether Cylinder Optional Ether Starting Aid After installing cylinder, wait atRemote A/V Control Receptacle RC3 Stop engine Remote 14 Receptacle RC3 Information OptionalTerminal Strip 2T Connections Optional SocketStandard Controls See Section − Operating the Welding GeneratorIf light goes on, stop engine and check engine belt Do not switch under loadDescription Of Standard Controls See Section If light goes off, stop engine and check oil levelControls For Models With CV Option See Section This unit has a max OCV control circuit 120 V 15 a AC Receptacle RC2 240 V 15 a AC Receptacle RC1 Auxiliary power is not affected by weld output− Operating Auxiliary Equipment Volt And 240 Volt Duplex ReceptaclesBritish Receptacle Option Optional Auxiliary Power ReceptaclesGfci Receptacle Option Australian And South African Receptacle OptionsLoad Terminals Connecting Optional Auxiliary Power PlantSet Engine Control switch to Run when using auxiliary power 1011− Maintenance & Troubleshooting Deutz F3L912 Diesel Engine Maintenance LabelServicing Air Cleaner To clean air filterHose Servicing Fuel And Lubrication Systems Adjusting Engine Speed Servicing Optional Ether Starting Aid1850 Stop engine To check belt tension To adjust belt tensionChecking And Replacing Alternator Belt 13 mm Max Tools Needed 11/16Resetting Fan Belt Safety Shutdown Stop engine and let cool Inspecting And Cleaning Optional Spark Arrestor MufflerStop engine and let cool. Reinstall cleanout plug Overload Protection For Models With CV OptionWelding TroubleshootingEngine Auxiliary PowerTrouble Remedy OM-129 647 Circuit Diagram For Welding Generator Standard Models − Electrical DiagramsCircuit Diagram For Welding Generator Models With CV Option 184 954-C Wetstacking − RUN-IN ProcedureLoad Bank Run-In Procedure Using Load BankFrom flammables Run-In Procedure Using Resistance GridDo not touch hot exhaust Bank/grid− Auxiliary Power Guidelines Selecting EquipmentGrounding Generator To Truck Or Trailer Frame Use ground device as stated in electrical codes Grounding When Supplying Building SystemsHow Much Power Does Equipment Require? Earth ground if supplyingFarm/Home Equipment Rating Starting Watts Running Watts Approximate Power Requirements For Industrial MotorsApproximate Power Requirements For Farm/Home Equipment Industrial Motors Rating Starting Watts Running WattsContractor Rating Starting Watts Running Watts Approximate Power Requirements For Contractor EquipmentKVA/HP x HP x 1000 = Starting Amperage Volts Power Required To Start MotorHow Much Power Can Generator Supply? Single-Phase Induction Motor Starting RequirementsCustomer-supplied equipment is required if Generator is to supply standby power duringEmergencies or power outages Welding Generator Auxiliary Power output circuitSelecting Extension Cord Use Shortest Cord Possible 101 100 − Parts List66 65 102 Dia Part Description Quantity Mkgs Optional Panel, Front w/Components CC Model Illustrated Panel, Front w/Components -1 Item 6 5 GeneratorGenerator -1 Item 171 Hardware is common Not available unless listedIncludes Control Box CC/CV -1 Item 86 Optional Panel, Mtg Components CC/CV Model Panel, Mtg Components CC Model Page Service Your distributor also givesSupport Miller Electric Mfg. Co To locate distributor nearest you call 1-800-4-A-MillerFor assistance in filing or settling claims