Simer Pumps 3075SS-01 owner manual General Information / Installation

Page 4

General Information / Installation

4

Use the Ace-In-The-Hole Automatic Booster Pump to boost city water pressure. Plumbing connections are described in this manual.

GENERAL INFORMATION

Pump only clean water with your Ace-In-The-Hole Automatic Booster Pump. To avoid clogging the pump and damaging the shaft seal, do not pump water containing solids, foreign material, sand, silt, or abrasives.

If you are boosting the pressure from a well pump, be sure that the system check valves are tight. If the sys- tem pressure drops when the well pump is not run- ning, the Ace-In-The-Hole Automatic Booster Pump may start and cycle. Excessive or rapid cycling may damage the motor and will void the warranty.

Do not use pipe joint compound on pump ports; use only teflon tape to seal the threads. Pipe joint com- pound will damage the controller materials.

NOTE: The priming plug has an O-ring already installed and does not require sealing.

Tighten all the piping joints to the pump hand tight plus 1-1/2 turns (not more).

Overtightening may break the pump and will void the warranty.

Pipe and fittings to the pump should be at least nominal 1” diameter. Pipe or fittings less than 1” in diameter will reduce performance and may damage the pump through cavitation.

Make sure that there are no air leaks or air pockets in the suction pipe. An air leak in the suction pipe may draw air in, although no water leaks out. Air leaks and air pockets will prevent the pump from priming prop- erly, and can substantially reduce its performance.

The pump mount should be level, solid, as near as possible to the water source, and protected against excess moisture and flooding.

Use the shortest possible run for piping and the smallest possible number of fittings. Long pipe runs and numerous fittings increase friction and reduce the flow of water.

Support the weight of the piping and pump.

Do not allow the pump, pressure controller, or any system components to freeze. Freezing will damage the pump and void the warranty.

Periodically inspect the pump, pressure controller, and system components.

NOTE: Local code may require a pressure relief valve or pressure regulator.

Risk of leaks and flooding. Do not use this pump with inlet pressure greater than 50 psi (345 kPa).

Pressure hazard and risk of explosion. This pump can develop high pressure when operated with the discharge shut off or obstructed. For safe operation, we recommend the following:

If not already in the plumbing system, install a pressure relief valve in the pump discharge line capable of passing the full pump flow at 100 psi (689 kPa). If local code requires installation of a pressure relief valve capable of handling the full pump flow at a pressure less than 100 psi (689 kPa), follow the code requirements. Run the relief valve discharge to a floor drain or other drain that will give adequate runoff.

Figure 1 – Do Not Run the Pump With Inlet Shut Off

To Household

Grounded, GFCI

(Pump Discharge)

protected 115V outlet

Unions

 

Check Valve

Water Supply In

5680 0807

(Pump Suction)

 

Figure 2:Typical household booster installation. Purchase plumbing fittings separately. Consult code for relief valve/pressure regulator requirements.

INSTALLATION

Risk of flooding. Be sure that all plumbing and fittings are rated to withstand the system pressure which you expect the pump to generate.

1.Decide what’s the best place to install the pump. Think about these things:

it must be near the main water supply line

the pump must be accessible

the power cord must reach a power outlet

the controller’s LED lights must be visible

ease of plumbing

space saving

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 4
Contents Installation/Operation/Parts Automatic Booster PumpAutomatique Bomba automática de refuerzoSafety Read and Follow Safety InstructionsGeneral Safety Electrical SafetyTable of Contents Installation General Information / InstallationGeneral Information Installation Installation / Operation When does the Pump Stop OPERATING?Electrical Connection Automatic Pressure ControllerTroubleshooting Pump Service Operation / Service / TroubleshootingLubrication Model 3075SS-01 Repair PartsKey Part 3075SS-01 Description Ce symbole indique qu’il faut être prudent. Lorsque ce SécuritéConsignes DE Sécurité Générales Laver. Ne pas l’immerger. Le protéger contre la pluieTable des matières Attacher LE Reçu Dorigine ICI À DES Fins DE GarantieRenseignements généraux et Installation Renseignements GénérauxArrivée Water ’eauSupply Installation et fonctionnement Branchements ÉlectriquesServorégulateur Quand LA Pompe CESSE-T-ELLE DE FONCTIONNER?Lubrification Fonctionnement, entretien et dépannageDépannage Entretien DE LA Pompe Pièces de rechange Modèle 3075SS-01Désignation 3075SS-01 Des pièces QtéInstrucciones Generales DE Seguridad SeguridadEste es el símbolo de alerta de seguridad. Cuando vea Índice PáginaInformación General Información general / InstalaciónInstalación Instalación Riesgo de explosión de la manguera y deInstalación / Operación Conexiones EléctricasControlador Automático DE Presión ¿CUÁNDO Deja DE Funcionar LA BOMBA?Lubricación Operación / Servicio / Localización de fallasLocalización DE Fallas Servicio DE LA Bomba Modelo 3075SS-01 Repuestos para la reparaciónClave Descripción 3075SS-01 De la pieza

3075SS-01 specifications

Simer Pumps has established a reputation for high-quality, reliable water movement solutions, and the Simer Pumps 3075SS-01 model is a prime example of this commitment to excellence. Designed for both residential and commercial applications, the 3075SS-01 is a submersible utility pump that caters to a diverse array of pumping needs, including draining flooded basements, emptying swimming pools, and managing groundwater.

One of the standout features of the 3075SS-01 is its robust construction, which includes a stainless steel housing. This not only enhances its durability but also ensures resistance to corrosion, making it an ideal choice for prolonged use in harsh environments. The pump is designed to handle various water types, including clean water and those with small particles suspended in them, making it versatile for different pumping applications.

Equipped with a powerful motor, the Simer 3075SS-01 can deliver an impressive flow rate. This efficiency means that it can quickly remove water, significantly reducing the time needed for draining tasks. The pump’s maximum pumping capacity reaches around 3,300 gallons per hour, with an impressive head height, allowing it to move water effectively from deeper spaces.

The 3075SS-01 also boasts an automatic float switch, which activates the pump when water levels rise beyond a certain point. This feature ensures that the pump operates without the need for manual intervention, providing peace of mind for users who may be away from the pump while it operates. Additionally, the float switch is adjustable, enabling users to set the operational range according to specific needs.

Another characteristic that enhances the versatility of the Simer 3075SS-01 is its compact and lightweight design. This enables easy handling and transportation, allowing users to position the pump conveniently in different locations as needed. The built-in handle further facilitates easy transport, making it user-friendly for both professionals and DIY enthusiasts.

Overall, Simer Pumps' 3075SS-01 model combines powerful performance with reliable construction and user-friendly features, making it an excellent choice for anyone in need of an efficient and durable submersible utility pump. With its advanced technologies and thoughtful design, this pump stands out for its ability to handle a variety of water movement tasks with ease, ensuring reliability when it matters most.