Simer Pumps 3075SS-01 owner manual Installation / Operation, Electrical Connection

Page 6

Installation / Operation

6

ELECTRICAL CONNECTION

Hazardous voltage. Risk of dangerous or fatal electric shock. Plug the pump into a 115 Volt,

60 Cycle, Ground Fault Circuit Interrupter (GFCI) pro- tected grounded outlet only. The pump is equipped with a 3-wire grounded cord and plug. Do not modify or remove the plug. Make sure the outlet meets the National Electric Code or the Canadian Electrical Code, as applicable. To avoid dangerous electrical shock haz- ard, keep the cord dry at all times. See Figure 2.

AUTOMATIC PRESSURE CONTROLLER

The Automatic Pressure Controller mounts on the pump. It protects against:

Run-dry operation;

Frequent starts caused by small water losses in the system;

Pressure drop.

The Automatic Pressure Controller features the following LEDs and controls:

‘Power on’ LED: indicates that the unit is electrically connected and that voltage is present. The pump is ready to operate.

‘Pump on’ LED: indicates that the pump is running and actually pumping water.

‘Failure’ LED: indicates that no water is detected coming into the pump.

‘Restart’ button: resets any safeties which have tripped and allows the pump to restart.

‘Power on’ LED ‘Pump on’ LED

‘Failure’ LED

‘Restart’ Button

Figure 4 - Ace-In-The-Hole Automatic Booster Pump Control Panel

NORMAL OPERATION OF THE ACE-IN-THE-HOLE AUTOMATIC BOOSTER PUMP

Burn Hazard. NEVER run the pump dry. Running the pump without water may cause pump to overheat and cause burns to persons handling the pump. It may also damage the impeller and may damage the seal, causing leaking or flooding, and will void the war- ranty. Fill the pump with water before starting it.

Make sure that the Ace-In-The-Hole Automatic Booster Pump has been properly installed, primed (see page 4), and that the suction pipe is unobstructed and open.

Plug in the pump. The ‘Power on’ and ‘Pump on’ lights will come on indicating, respectively, that voltage is pre- sent and that the pump is ready to operate.

The pump will start and will continue to operate until several seconds after the system pressure has risen and flow has stopped.

WHEN DOES THE PUMP

STOP OPERATING?

Pressure Set-Point/No Flow: The pump will stop operat- ing and the ‘Pump on’ LED will go off several seconds after:

The system pressure is above the starting pressure, and

The flow has stopped. This is normal operation.

Restart: A water flow in the system greater than

1/4 GPM or a drop in pressure below the starting pres- sure set-point will cause the pump to restart and the ‘Pump on’ LED to light up. The pump will continue to operate until several seconds after:

It reaches the maximum pressure of the pump, and

The flow stops.

NOTE: The delay in shutting off the pump prevents rapid cycling when water faucets are being turned on and off quickly (for example, when brushing teeth, etc.).

Pressure Drop/No Flow: Normally, when the pump starts, it will very quickly generate pressure and sense flow. If there is no flow and the pressure does not rise, it senses a “no water” condition. It can also sense this dur- ing operation if the water supply to the pump fails. To protect the pump from running dry:

Several seconds after it detects “no water”, the pump will stop operating,

The ‘Pump on’ LED will go out, and

The ‘Failure’ LED will go on.

For parts or assistance, call Simer Customer Service at 1-800-468-7867

Image 6
Contents Automatique Installation/Operation/PartsAutomatic Booster Pump Bomba automática de refuerzoGeneral Safety SafetyRead and Follow Safety Instructions Electrical SafetyTable of Contents General Information / Installation InstallationGeneral Information Installation Electrical Connection Installation / OperationWhen does the Pump Stop OPERATING? Automatic Pressure ControllerOperation / Service / Troubleshooting Troubleshooting Pump ServiceLubrication Repair Parts Model 3075SS-01Key Part 3075SS-01 Description Consignes DE Sécurité Générales Ce symbole indique qu’il faut être prudent. Lorsque ceSécurité Laver. Ne pas l’immerger. Le protéger contre la pluieTable des matières Attacher LE Reçu Dorigine ICI À DES Fins DE GarantieRenseignements généraux et Installation Renseignements GénérauxArrivée Water ’eauSupply Servorégulateur Installation et fonctionnementBranchements Électriques Quand LA Pompe CESSE-T-ELLE DE FONCTIONNER?Fonctionnement, entretien et dépannage LubrificationDépannage Entretien DE LA Pompe Désignation 3075SS-01 Pièces de rechangeModèle 3075SS-01 Des pièces QtéSeguridad Instrucciones Generales DE SeguridadEste es el símbolo de alerta de seguridad. Cuando vea Índice PáginaInformación general / Instalación Información GeneralInstalación Instalación Riesgo de explosión de la manguera y deControlador Automático DE Presión Instalación / OperaciónConexiones Eléctricas ¿CUÁNDO Deja DE Funcionar LA BOMBA?Operación / Servicio / Localización de fallas LubricaciónLocalización DE Fallas Servicio DE LA Bomba Repuestos para la reparación Modelo 3075SS-01Clave Descripción 3075SS-01 De la pieza

3075SS-01 specifications

Simer Pumps has established a reputation for high-quality, reliable water movement solutions, and the Simer Pumps 3075SS-01 model is a prime example of this commitment to excellence. Designed for both residential and commercial applications, the 3075SS-01 is a submersible utility pump that caters to a diverse array of pumping needs, including draining flooded basements, emptying swimming pools, and managing groundwater.

One of the standout features of the 3075SS-01 is its robust construction, which includes a stainless steel housing. This not only enhances its durability but also ensures resistance to corrosion, making it an ideal choice for prolonged use in harsh environments. The pump is designed to handle various water types, including clean water and those with small particles suspended in them, making it versatile for different pumping applications.

Equipped with a powerful motor, the Simer 3075SS-01 can deliver an impressive flow rate. This efficiency means that it can quickly remove water, significantly reducing the time needed for draining tasks. The pump’s maximum pumping capacity reaches around 3,300 gallons per hour, with an impressive head height, allowing it to move water effectively from deeper spaces.

The 3075SS-01 also boasts an automatic float switch, which activates the pump when water levels rise beyond a certain point. This feature ensures that the pump operates without the need for manual intervention, providing peace of mind for users who may be away from the pump while it operates. Additionally, the float switch is adjustable, enabling users to set the operational range according to specific needs.

Another characteristic that enhances the versatility of the Simer 3075SS-01 is its compact and lightweight design. This enables easy handling and transportation, allowing users to position the pump conveniently in different locations as needed. The built-in handle further facilitates easy transport, making it user-friendly for both professionals and DIY enthusiasts.

Overall, Simer Pumps' 3075SS-01 model combines powerful performance with reliable construction and user-friendly features, making it an excellent choice for anyone in need of an efficient and durable submersible utility pump. With its advanced technologies and thoughtful design, this pump stands out for its ability to handle a variety of water movement tasks with ease, ensuring reliability when it matters most.