FEATURES

This air conditioner is an inverter type unit that automatically adjusts capability as appropriate. Details on these functions are provided below; refer to these descriptions when using the air conditioner.

• Microprocessor Controlled Operation

The interior compartment of the remote control unit contains several features to facilitate automatic operation, easy logically displayed for easy use.

• Simple One-touch Wireless Remote Control

The remote control unit has several features to facilitate automatic operation.

24-Hour ON or OFF Timer

This timer can be set to automatically turn the unit on or off at any time within a 24 hour period.

1-Hour OFF Timer

This timer can be set to automatically turn off the unit at any time after one hour.

• Night Setback

This function saves energy by controlling operation to provide a quieter operating sound than normal.

Automatic and 3-step Fan Speed

Auto/High/Medium/Low

Air Sweep Control

This function moves a flap up and down in the air outlet, directing air in a sweeping motion around the room and providing comfort in every corner.

• Auto. Flap Control

This automatically sets the flap to the optimum position during heating, cooling, and drying operation.

• Automatic Switching between Cooling and Heating

This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the temperature setting.

• Hot Start Heating System

Right from the start, the air is warm and comfortable. This system prevents any cold blasts at the beginning while the heat pump is warming up, or even defrosting.

• Automatic Restart Function for Power Failure

Even when power failure occurs, preset programmed operation can be reactivated once power resumes.

• High Power Operation

If not in Auto Operation, the unit operates at maximum output for 30 minutes, regardless of the desired temperature.

The fan speed is 1 step above “High”.

• Quiet Operation

The fan rotates slower than the fan speed setting to provide a quieter operating sound.

• LED Clean Operation

During operation, the UV anti-bacteria unit is activated for 30 minutes and cleans the air blown from the air conditioner.

Anti-Mold Filter

This unit is equipped with an anti-mold filter that inhibits the growth of mold and bacteria.

• Air Clean Filter

An air filter that eliminates unpleasant odors and cleans the air is available.

Purchase a replacement filter at your local dealer. (model STK-FDXB)

• Unoccupied

This function prevents the room temperature from decreasing too much (or increasing too much) when no one is in the room, and operate automatically to save energy.

CONTENTS

 

 

Page

FEATURES

2

PRODUCT INFORMATION

3

ALERT SYMBOLS

3

INSTALLATION LOCATION

3

ELECTRICAL REQUIREMENTS

3

SAFETY INSTRUCTIONS

3

NAMES OF PARTS

4

USING THE REMOTE CONTROL UNIT

8

OPERATION WITH THE REMOTE CONTROL UNIT

9

1.

Automatic Operation

9

2.

Manual Operation

9

3.

Adjusting the Fan Speed

10

4.

Fan Only

10

5.

Night Setback Mode

10

6. QUIET Mode

10

7. HIGH POWER Mode

11

8. LED CLEAN Mode

11

9. UNOCCUPIED Mode

11

 

Page

SPECIAL REMARKS

12

SETTING THE TIMER

13

USING THE 1-HOUR OFF TIMER

14

TIPS FOR ENERGY SAVING

14

ADJUSTING THE AIRFLOW DIRECTION

15

OPERATION WITHOUT THE REMOTE CONTROL UNIT

15

CARE AND CLEANING

15

TROUBLESHOOTING

17

OPERATING RANGE

17

WIRED REMOTE CONTROLLER

17

2

OI-149-2-EG

 

Image 62
Contents Indoor Model No. Product Code No Destination North AmericaSafety Precautions Prohibit Table of Contents Checking Electrical Components Operating Range Indoor Air Intake Temp Outdoor Air Intake TempKHS3082 SpecificationsUnit Specifications CH3082208V KHS3682 CH368221.9 19.9 Major Component Specifications Indoor UnitCB-KHS3682 Microprocessor 250V 3A Board Outdoor UnitOutdoor Unit CH3082 CompressorOutdoor Unit CH3682 Other Component Specifications Dimensional Data Indoor Unit KHS3082Inchmm Refrigerant Flow Diagram Refrigerant Flow DiagramOperating current performance chart Temperature ChartsLow pressure performance chart Indoor discharge air performance chartHigh pressure performance chart Wide Outdoor inlet air D.B. temp. FC Cooling Capacity Indoor OutdoorCooling Capacity Indoor34,000 BTU/h Power Supply 230V Single Phase 60Hz Cooling Capacity IndoorTH Total Heating Capacity BTU/h Power Supply 230V Single Phase 60Hz Heating CapacityHeating Capacity 36,000 BTU/h Room air temp F 26.7C Fan speed High Horizontal distance ft Air Throw Distance ChartsCooling Vertical distance ft Heating Vertical distance ftHeating CH3082 Voltage230V Cooling Electrical CharacteristicsElectrical Data Voltage208V CoolingCH3682 Voltage230V Cooling 8FA2-5250-70400-3 Electric Wiring DiagramsKHS3082 KHS3682 HIC Emergency operation FunctionsOperation Functions Auto cooling/heating operationTimer backup Lamp colorsOperation Sound Switching Procedure to Noise Reducing ControlNoise Reducing Control Outdoor Unit Description of function Maximum Current Value Change ProcedureMaximum Current Value Change Function CH3682Overload prevention during heating Compressor discharge temperature controlProtective Functions Freeze preventionReverse-Cycle Defrosting Defrost detection and releaseCT Peak current cut-off control Method of Self-Diagnostics TroubleshootingPrecautions before Performing Inspection or Repair Self-diagnostics Lamps Replace the circuit board or the fuse NormalReplace the controller Checking the indoor unit Control Check items unit operation Using the TEST/T-RUN terminalsChecking the Indoor and Outdoor Units Off Blinking Illuminated Serial Communication Error Identification ProcedureAlarm Code E05 Before the OperationTerminal board Outdoor Unit Alarm Code E07/P04/P05/P20/P27 Trouble Diagnosis of Fan Motor Indoor Fan MotorOutdoor Fan Motor Electromagnetic interference Noise Malfunction and Electromagnetic InterferenceNoise malfunction Locations most susceptible to noise Trouble CorrectionMeasurement of Insulation Resistance Power Supply CordChecking Electrical Components Measurement of Insulation Resistance for Electrical PartsChecking Continuity of Fuse on PCB Assy What is New Refrigerant R410A? Refrigerant R410A Special Precautions When Servicing UnitCharacteristics of New Refrigerant R410A CharacteristicsChecklist before Servicing Tubing Installation Procedures Tools Specifically for R410AProcedure for Replacing Compressor Case of Compressor MalfunctionDamage to the compressor Never charge a large amountUnit. This may cause ExampleRecharging Case Refrigerant is LeakingWelding leaking points Retro-Fitting Existing Systems When Tubes are ExtendedCharging Additional Refrigerant Use of Existing UnitsOI-852-6-4181-149-00-0 Mode D’EMPLOI Pub. OI-85264181149000 SanyoFeatures ContentsSafety Instructions Alert SymbolsInstallation Location Product InformationNames of Parts Unit Display and Operation ButtonRemote Control Unit Display SymbolsRemote Control Unit Mode selector button HR. Timer button 1-HOUR OFF TimerTemperature setting buttons Temp High Power buttonACL button Using the Remote Control UnitAir conditioner Indoor unit Receiver Remote control unit 16 mmOperation with the Remote Control Unit Automatic OperationAutomatic fan speed Cooling and DRY ModeHeating Mode Manual fan speedHigh Power Mode Unoccupied Indication StatusSpecial Remarks Setting the Timer Operation IndicationDo not Using the 1-HOUR OFF TimerTips for Energy Saving 1030 pm 710 am 1100 am Present timeCare and Cleaning Adjusting the Airflow DirectionOperation Without the Remote Control Unit When the air conditioner is not runningHow to clean the air clean filter Air Clean FilterHow to install the air clean filter Cleaning the main unit and remote control unitOperating Range TroubleshootingWired Remote Controller Washing the front panel with waterAppendix B Installation Instructions Installation Instructions ContentsPlease Read Before Starting General Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationSolid base must not cover the hole of the bottom plate Precautions for Installation in a Snowy Area Countermeasures against snow and windUnit inch Front and both sides must remain open Installation with intakes facing outletsRequired space around the outdoor unit Unit Obstacle to the front of unit Top is open Single-unit installationMultiple-unit installation 2 or more units Installation in front-rear rows Obstacles to the front and rear of unitRemove the Rear Panel from the Unit How to Install the Indoor UnitTrical wiring or conduits are Make a HoleIf Block, Brick, Concrete or Similar Type Wall Install the Rear Panel on the WallIf Wooden Wall Hole DiaHow to replace the grille Removing and Installing the GrilleHow to remove the grille Wiring Instructions General precautions on wiring Shape the Indoor Side TubingWire Size and Length Wiring Instructions for Inter-unit Connections For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit For solid core wiring or F-cable Mounting Right-side tubingDrain cap Switching drain hose and drain capLeft-side tubing To unmount indoor unit Do not supply power toTubing and wiring to the out Frame Fastening MethodWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitFirst refer to . Installation Site Selection Routing the Tubing and WiringUse of the Flaring Method Flaring Procedure with a Flare ToolRefrigerant Tubing If the special R410A flare tool is usedInsulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation Taping the TubesAir Purging Attempting to turn the valve Be sure to completely insertHex wrench before How to Test Run the Air Conditioner Basic Functions of the Service Valves Pump DownService Valve Connections Remote Control Unit Installation PositionAddress Switch Address Setting of the Remote Control Unit