Siemens 38-3AH3 38 kV instruction manual Introduction, Field service operation and warranty issues

Page 5

Introduction

Field service operation and warranty issues

Siemens can provide competent, well trained field service representatives to provide technical guidance and advisory assistance for the installation, overhaul, repair and maintenance of Siemens equipment, processes and systems. Contact regional service centers, sales offices or the factory for details, or telephone Siemens field service at

+1 (800) 347-6659 or +1 (919) 365-2200 outside the U.S.

For medium-voltage customer service issues, contact Siemens at

+1 (800) 347-6659 or +1 (919) 365-2200 outside the U.S.

5

Image 5 Contents
Answers for energy Qualified person Table of contents Introduction Signal words Hazardous ProceduresIntroduction Introduction Field service operation and warranty issuesShipping damage claims Introduction Receiving procedureReceiving, handling and storage Receiving, handling and storage Handling procedureIndoor storage Storage procedureOutdoor storage Space heatingDe-energizing control power in switchgear Installation checks and functional testsInspections, checks and tests without control power Installation checks and functional tests Type 38-3AH3 vacuum circuit breaker racking Racking crank engagement procedureManual-spring charging check Physical inspectionsSplit-plug jumper connected to circuit breaker Final mechanical inspections without control powerVacuum interrupter/ operator Vacuum interrupters Vacuum interrupter/ operatorStored-energy operating mechanism Phase barriersPrimary disconnects Construction Interrupter/operator moduleSwitching operation Current-path assemblyCircuit-breaker pole Vacuum interrupterType 38-3AH3 vacuum circuit breaker pole section Stored-energy operating mechanism Mode of operation Auxiliary switchOperating mechanism Indirect releases tripping coilsUse of manual-spring operation crank ClosingOpening Trip-free functionalityRapid auto-reclosing Manual operation62.2 62.5.2 50.3.1 53.0 Pawl roller 62.5.2 Close-latch pawl Vacuum interrupter/ operator Discharged Closing Standard Undervoltage optional Indirect releases dual-trip orSecondary shunt release optional 54.2Position a locked Secondary disconnect Capacitor-trip deviceShock absorber Truck-operated cell TOC switch Mechanism-operated cell MOC switch optionalShutter-operating linkage Secondary disconnect Shutters Rating interlock Trip-free interlockCircuit-breaker frame Ground disconnectVehicle function and operational interlocks Racking mechanismAlignment Interlocks Circuit breaker racking-interlocksRacking interlocks Closed circuit breaker interlock Automatic closing-spring energy release Trip-free interlock position mechanical interlock Introduction and maintenance intervals MaintenanceRecommended hand tools MaintenanceInspection items and tests Recommended maintenance and lubricationCleanliness check Removal from switchgearChecks of the primary power path Circuit Number Maintenance and lubricationInspection of primary disconnects Checks of the stored-energy operator mechanismTypical for all three-phases Manual-spring charging and contact- erosion checks Fastener checkAutomatic spring-charging check control power required Wiring and terminals checkElectrical-control checks Secondary-disconnect checkTypical vacuum interrupter contact curve Vacuum-interrupter mechanical check Spring-charging motor checksHigh-potential test voltages Vacuum-integrity check using dielectric testHigh-potential tests Voltage Frequency withstand Field-test voltageContinuous Contact Inspection and cleaning of circuit- breaker insulationRating a Functional testsOverhaul Replacement at overhaulCircuit-breaker overhaul Circuit breaker Number TypeOverhaul Vacuum interrupter replacementSetting Vacuum interrupter replacement illustration Overhaul Hydraulic shock absorber Checking the contact stroke Open the circuit breakerSub-assembly Inspect for Maintenance and troubleshootingProblem Symptoms Possible causes and remedies Maintenance and troubleshootingClosed Appendix Appendix Maximum design voltage Permissible tripping delay YValues Voltage Voltage range factor K3 Insulation Withstand Voltage levels Lightning-impulse BILLevels Voltage levels Lightning-impulse BIL Rated Maximum design voltageRated Continuous4 Short-circuit at rated maximum design voltage I5, 6Remarks Appendix