Infortrend SentinelRAID 170 320ML/sec SCSI-to-SCSI RAID Controller manual SentinelRAID Connection

Page 37

Chapter 4: Controller Connections and Operation

Chapter 4

Controller Connections and

Operation

4.1. SentinelRAID Connection

4.1.1 I/O Channel Configuration

All of the I/O channels can be configured as either host channels or drive channels. Note that at least one I/O channel on the SR 170 controller must be configured as a host channel and the other channels can all be configured as drive channels.

4.1.2 SCSI Cables

Separately purchased SCSI-320 compatible cables, not longer than 12 meters, must be used for host and drive connection. Purchase SCSI-320 cables of the highest quality produced by a reputable manufacture. It is necessary to use proper, high quality, durable SCSI-320 cables in order to ensure optimum SR controller performance. Failure to do so will result in downgraded performance.

SCSI cables that are used to connect the SR 170 controller to external SCSI-320 devices should be in compliance with the specifications shown in Table 4-1.

Electrical

Impedance

120ΩΚ10%

 

 

Capacitance

15.9 pf / ft @ 1MHz

 

 

Propagation Delay

1.59ns / ft nom

 

 

DC Resistance

95/ 1000 ft @ 20°C

 

 

Delay Skew

0.035ns / ft (max.)

 

 

Table 4-1: SCSI-320 Cable Electrical Specifications

4.1.3 Host Connection

I/O channels configured as host channels can be connected to a SCSI-320 host computer using an industry-standard SCSI-320 cable.

SentinelRAID Connection

4-1

Image 37
Contents 320MB/sec SCSI-to-SCSI RAID Controller Installation and Hardware Reference ManualAsia Pacific International Headquarters Contact InformationChina AmericasThis Edition First Published CopyrightDisclaimer TrademarksThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting Precautions and Instructions Safety PrecautionsESD Precautions About This ManualConventions Who should read this manual?Related Documentation NamingSoftware and Firmware Updates Product Overview Chapter IntroductionProduct Introduction Controller Box EnclosureFront Side Rear SideLCD Panel SR ComponentsController Board JP1 and JP13 Connector Type Label DescriptionController Board Front InterfacesConnector Type Label Description Separately Purchased Accessory Items SR Accessory Items4 I2C Signal Compatible Cables Power ConnectorBattery Backup Unit BBU Optional ItemsEnvironmental Requirements Power Supply RequirementsDaughter Board Expansion SR Controller Monitoring LED IndicatorsCooling Requirements 1 I2C BusAudible Alarms This page is intentionally left blank Installation Overview Chapter InstallationInstallation Prerequisites General ConsiderationsStatic-free Installation Hardware Installation PreparationTools or Equipment Needed for Installing the Subsystem Planning Before InstallationUnpacking the Controller General Installation ProcedureOverview Accessing the Controller BoardRemoving and Replacing the Chassis Top Cover Dimm Module Installation Procedure Memory Module InstallationSelecting the DIMMs About the First BBU Installation Battery Backup Unit BBU InstallationRemove the Battery Connector Cap BBU Installation ProcedureInstall the Battery Charger Board About Daughter Board Installation Daughter Board InstallationDaughter Board Installation Procedure Daughter Board Installation Controller Monitoring Overview Chapter Controller MonitoringPWR Status-indicating LEDsDefault Threshold Values Audible AlarmI2C Port Enclosure Monitoring I2C Port Enclosure Monitoring Chapter Controller Connections Operation 1 I/O Channel ConfigurationSentinelRAID Connection Host ConnectionDrive Connection SR 170 TopologiesScsi Termination Unique IDsSR 170 Topologies Dual Host Connection Dual Host ConnectionExpansion Controller IntegrationConnecting RS-232C Terminal Emulation Power ConnectionOther Connections Check List Power OnLCD Screen Power On SequenceStop I/O access to the system Disconnect the host Power Off ProcedurePower Off Procedure Controller Maintenance Overview Chapter Controller MaintenanceAbout Controller Maintenance User Serviceable ComponentsDimm Module Replacement Procedure When should a Dimm module be replaced?Replacing a failed Dimm Module Replacing a failed Dimm Module Replacing a Failed Optional BBU Module About BBU MaintenanceOnce the controller board has pack from the charger board BBU Charger Board Replacement Daughter Board MaintenanceAbout Daughter Board Maintenance Replacing a Daughter BoardRemove the Daughter Board Retention Screws This page is intentionally left blank Flexible Configuration Appendix a SentinelRAID FeaturesUser-friendly Configuration Utilities SCSI-320 I/O ChannelsController Architecture Other Fault Tolerant FeaturesGlobal and Local Spares Hot-swapping of DrivesController Chassis RAID Levels SupportedThis page is intentionally left blank Configuration Appendix B Hardware SpecificationsSpecification Feature RAID Management Controller ArchitectureFault Tolerance Specification Size Technical SpecificationsDescription Specification SoftwareController Specifications Technical Specifications Problem Appendix C Hardware TroubleshootingProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Accessories Appendix D Spare Parts and AccessoriesAccessory Part Number Description Spare PartsAccessories Controller Main Board Interfaces Appendix E Connectors and Jumper IdentificationController Main Board Interface Descriptions Label Connector NameCOM Port Pin Outs LED Jumper Pin OutsPin Description J3 I2C Port Symbol Type DescriptionPin Pin Name Symbol Parameter Rating Unit J1 Battery ConnectorTTL Device Parameters PinIFT-9012 RS-232C Extension Cable IFT- 9011 Null ModemIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank