Chapter 4: Controller Connections and Operation
Chapter 4
Controller Connections and
Operation
4.1. SentinelRAID Connection
4.1.1 I/O Channel Configuration
All of the I/O channels can be configured as either host channels or drive channels. Note that at least one I/O channel on the SR 170 controller must be configured as a host channel and the other channels can all be configured as drive channels.
4.1.2 SCSI Cables
Separately purchased
SCSI cables that are used to connect the SR 170 controller to external
Electrical
Impedance | 120ΩΚ10% |
|
|
Capacitance | 15.9 pf / ft @ 1MHz |
|
|
Propagation Delay | 1.59ns / ft nom |
|
|
DC Resistance | 95Ω / 1000 ft @ 20°C |
|
|
Delay Skew | 0.035ns / ft (max.) |
|
|
Table
4.1.3 Host Connection
I/O channels configured as host channels can be connected to a
SentinelRAID Connection |