Infortrend SentinelRAID 170 320ML/sec SCSI-to-SCSI RAID Controller manual Configuration

Page 59

Appendix B: Hardware Specifications

Appendix B

Hardware Specifications

B.1. Configuration

Specification

Feature

 

 

RAID Levels

0, 1(0+1), 3, 5, 10, 30, 50, JBOD, and non-RAID disk

 

spanning

 

 

Host O/S Compatibility

Host O/S independent

SCSI Channels

4 on base module

 

8 (with the expansion daughterboard)

 

 

Host Interface

SCSI-320

Host Channels

All channels can be configured as host or drive channels

Drive Interface

SCSI-320

 

 

Drive Channels

Up to 3; up to 7 with the expansion daughter board

 

 

Maximum Number of SCSI

Up to 105 (on 7 drive channels)

Drives

 

 

 

Cache Memory Size

At least 128MB, supports up to 1GB; PC-133 SDRAM

 

DIMM socket x1 with ECC support

 

 

Cache Mode

Write-through or write-back

Logical Drives

Up to 8

 

 

Partitions

Up to 8 per logical drive or logical volume, 64 total

Number of LUNs

Up to 32 per SCSI ID, 128 per controller

Multiple SCSI IDs per Host

Yes

Channel

 

 

 

Firmware on Flash Memory

Yes; main RAIDWatch agents included

 

 

Drive Hot Swapping

Yes

Table B-1: Controller Configuration

Configuration

B-1

Image 59
Contents 320MB/sec SCSI-to-SCSI RAID Controller Installation and Hardware Reference ManualAmericas Contact InformationAsia Pacific International Headquarters ChinaTrademarks CopyrightThis Edition First Published DisclaimerThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting About This Manual Safety PrecautionsPrecautions and Instructions ESD PrecautionsNaming Who should read this manual?Conventions Related DocumentationSoftware and Firmware Updates Product Introduction Chapter IntroductionProduct Overview Rear Side EnclosureController Box Front SideController Board SR ComponentsLCD Panel JP1 and JP13 Connector Type Label DescriptionController Board Front InterfacesConnector Type Label Description Separately Purchased Accessory Items SR Accessory ItemsOptional Items Power Connector4 I2C Signal Compatible Cables Battery Backup Unit BBUDaughter Board Expansion Power Supply RequirementsEnvironmental Requirements 1 I2C Bus LED IndicatorsSR Controller Monitoring Cooling RequirementsAudible Alarms This page is intentionally left blank General Considerations Chapter InstallationInstallation Overview Installation PrerequisitesPlanning Before Installation Hardware Installation PreparationStatic-free Installation Tools or Equipment Needed for Installing the SubsystemUnpacking the Controller General Installation ProcedureRemoving and Replacing the Chassis Top Cover Accessing the Controller BoardOverview Selecting the DIMMs Memory Module InstallationDimm Module Installation Procedure About the First BBU Installation Battery Backup Unit BBU InstallationRemove the Battery Connector Cap BBU Installation ProcedureInstall the Battery Charger Board Daughter Board Installation Procedure Daughter Board InstallationAbout Daughter Board Installation Daughter Board Installation Controller Monitoring Overview Chapter Controller MonitoringPWR Status-indicating LEDsI2C Port Enclosure Monitoring Audible AlarmDefault Threshold Values I2C Port Enclosure Monitoring Host Connection 1 I/O Channel ConfigurationChapter Controller Connections Operation SentinelRAID ConnectionUnique IDs SR 170 TopologiesDrive Connection Scsi TerminationSR 170 Topologies Dual Host Connection Dual Host ConnectionExpansion Controller IntegrationOther Connections Power ConnectionConnecting RS-232C Terminal Emulation Check List Power OnLCD Screen Power On SequenceStop I/O access to the system Disconnect the host Power Off ProcedurePower Off Procedure User Serviceable Components Chapter Controller MaintenanceController Maintenance Overview About Controller MaintenanceReplacing a failed Dimm Module When should a Dimm module be replaced?Dimm Module Replacement Procedure Replacing a failed Dimm Module Replacing a Failed Optional BBU Module About BBU MaintenanceOnce the controller board has pack from the charger board Replacing a Daughter Board Daughter Board MaintenanceBBU Charger Board Replacement About Daughter Board MaintenanceRemove the Daughter Board Retention Screws This page is intentionally left blank SCSI-320 I/O Channels Appendix a SentinelRAID FeaturesFlexible Configuration User-friendly Configuration UtilitiesHot-swapping of Drives Other Fault Tolerant FeaturesController Architecture Global and Local SparesController Chassis RAID Levels SupportedThis page is intentionally left blank Specification Feature Appendix B Hardware SpecificationsConfiguration RAID Management Controller ArchitectureFault Tolerance Software Technical SpecificationsSpecification Size Description SpecificationController Specifications Technical Specifications Problem Appendix C Hardware TroubleshootingProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Spare Parts Appendix D Spare Parts and AccessoriesAccessories Accessory Part Number DescriptionAccessories Controller Main Board Interfaces Appendix E Connectors and Jumper IdentificationController Main Board Interface Descriptions Label Connector NamePin Description LED Jumper Pin OutsCOM Port Pin Outs Pin Pin Name Symbol Type DescriptionJ3 I2C Port Pin J1 Battery ConnectorSymbol Parameter Rating Unit TTL Device ParametersIFT-9012 RS-232C Extension Cable IFT- 9011 Null ModemIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank