Infortrend 170 manual Replacing a Failed Optional BBU Module, About BBU Maintenance

Page 50

SentinelRAID Installation and Hardware Reference Manual

Step 7. Reinstall the optional BBU charger board. Once the new DIMM module is installed, if an optional BBU charger board was previously removed it can now be reinstalled onto the controller board. See Section 5.3.3 below.

Step 8. Reinstall the optional daughter board. Once the optional BBU charger board has been reinstalled, if an optional daughter board was previously installed on the controller board, it too can be reinstalled. See Section 5.4.2 below.

Step 9. Replace the chassis top cover. Once the DIMM module, optional BBU charger board and optional daughter board have all been reinstalled, the chassis top cover must be reinstalled. For detailed instructions on how to reinstall the chassis top cover, please refer to Section 2.6.2.

5.3. Replacing a Failed Optional BBU Module

5.3.1 About BBU Maintenance

Maintaining the BBU requires that two items be maintained:

BBU battery pack: The BBU battery pack contains the cells that provide power to the memory cache during a power outage. The battery pack is connected to the battery charger board or the connector at the back of the controller board. It is important that the BBU battery pack is replaced every two years.

BBU charger board: The BBU charger board is installed on the controller board. The charger board keeps the battery pack charged so that the BBU can support the cache memory during a power outage.

If either of these components fails, it will have to be replaced.

5.3.2 BBU Battery Pack Replacement

5.3.2.1Case 1: BBU Battery Pack Connected to the Controller Board Backplane Connector

If the BBU battery pack is attached to the connector on the rear of the controller board, the cable attached to this connector must be removed and the connector on the replacement battery pack connected. (See Figure 5-3)

5-4

Replacing a Failed Optional BBU Module

Image 50
Contents Installation and Hardware Reference Manual 320MB/sec SCSI-to-SCSI RAID ControllerChina Contact InformationAsia Pacific International Headquarters AmericasDisclaimer CopyrightThis Edition First Published TrademarksThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting ESD Precautions Safety PrecautionsPrecautions and Instructions About This ManualRelated Documentation Who should read this manual?Conventions NamingSoftware and Firmware Updates Product Introduction Chapter IntroductionProduct Overview Front Side EnclosureController Box Rear SideController Board SR ComponentsLCD Panel Connector Type Label Description JP1 and JP13Interfaces Controller Board FrontConnector Type Label Description SR Accessory Items Separately Purchased Accessory ItemsBattery Backup Unit BBU Power Connector4 I2C Signal Compatible Cables Optional ItemsDaughter Board Expansion Power Supply RequirementsEnvironmental Requirements Cooling Requirements LED IndicatorsSR Controller Monitoring 1 I2C BusAudible Alarms This page is intentionally left blank Installation Prerequisites Chapter InstallationInstallation Overview General ConsiderationsTools or Equipment Needed for Installing the Subsystem Hardware Installation PreparationStatic-free Installation Planning Before InstallationGeneral Installation Procedure Unpacking the ControllerRemoving and Replacing the Chassis Top Cover Accessing the Controller BoardOverview Selecting the DIMMs Memory Module InstallationDimm Module Installation Procedure Battery Backup Unit BBU Installation About the First BBU InstallationBBU Installation Procedure Remove the Battery Connector CapInstall the Battery Charger Board Daughter Board Installation Procedure Daughter Board InstallationAbout Daughter Board Installation Daughter Board Installation Chapter Controller Monitoring Controller Monitoring OverviewStatus-indicating LEDs PWRI2C Port Enclosure Monitoring Audible AlarmDefault Threshold Values I2C Port Enclosure Monitoring SentinelRAID Connection 1 I/O Channel ConfigurationChapter Controller Connections Operation Host ConnectionScsi Termination SR 170 TopologiesDrive Connection Unique IDsSR 170 Topologies Dual Host Connection Dual Host ConnectionController Integration ExpansionOther Connections Power ConnectionConnecting RS-232C Terminal Emulation Power On Check ListPower On Sequence LCD ScreenPower Off Procedure Stop I/O access to the system Disconnect the hostPower Off Procedure About Controller Maintenance Chapter Controller MaintenanceController Maintenance Overview User Serviceable ComponentsReplacing a failed Dimm Module When should a Dimm module be replaced?Dimm Module Replacement Procedure Replacing a failed Dimm Module About BBU Maintenance Replacing a Failed Optional BBU ModuleOnce the controller board has pack from the charger board About Daughter Board Maintenance Daughter Board MaintenanceBBU Charger Board Replacement Replacing a Daughter BoardRemove the Daughter Board Retention Screws This page is intentionally left blank User-friendly Configuration Utilities Appendix a SentinelRAID FeaturesFlexible Configuration SCSI-320 I/O ChannelsGlobal and Local Spares Other Fault Tolerant FeaturesController Architecture Hot-swapping of DrivesRAID Levels Supported Controller ChassisThis page is intentionally left blank Specification Feature Appendix B Hardware SpecificationsConfiguration Controller Architecture RAID ManagementFault Tolerance Description Specification Technical SpecificationsSpecification Size SoftwareController Specifications Technical Specifications Appendix C Hardware Troubleshooting ProblemProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Accessory Part Number Description Appendix D Spare Parts and AccessoriesAccessories Spare PartsAccessories Appendix E Connectors and Jumper Identification Controller Main Board InterfacesLabel Connector Name Controller Main Board Interface DescriptionsPin Description LED Jumper Pin OutsCOM Port Pin Outs Pin Pin Name Symbol Type DescriptionJ3 I2C Port TTL Device Parameters J1 Battery ConnectorSymbol Parameter Rating Unit PinIFT- 9011 Null Modem IFT-9012 RS-232C Extension CableIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank