Infortrend SentinelRAID 170 320ML/sec SCSI-to-SCSI RAID Controller manual Spare Parts, Accessories

Page 69

Appendix D: Spare Parts and Accessories

Appendix D Spare Parts and Accessories

D.1. Spare Parts

The following table lists the available spare parts for the SR 1700/2700 external controllers.

Spare Part

Part Number

Description

 

 

 

Daughter Board

IFT- 9284U4A

Expansion board with four

 

 

additional SCSI-320 interfaces

 

 

 

Table D-1: SR 170 Spare Parts

 

 

D.2. Accessories

The following table lists the available accessories for the SR 1700/2700 external controllers.

Accessory

Part Number

Description

 

 

 

Battery Charger

IFT-9070D

Mounted on the controller board; charges

 

 

the BBU

 

 

 

Battery Module

IFT-9010D

Supports a memory cache for up to 72

 

 

hours during a power failure

 

 

 

Battery Expansion

IFT-9519D

Connects the controller to a battery

Cable

 

 

 

 

 

Null Modem

9011

Facilitates serial connection between the

 

 

controller and terminal computer

 

 

 

Bezel Key

9531

Used for the removal of the front panel

 

 

 

COM 1/2 Combo Cable

9512

Serial port cable

 

 

 

Ethernet Cable

9537

Connects the controller to the internet for

 

 

online controller management

 

 

 

Table D-2: SR 170 Accessories

 

Spare Parts

D-1

Image 69
Contents 320MB/sec SCSI-to-SCSI RAID Controller Installation and Hardware Reference ManualAsia Pacific International Headquarters Contact InformationChina AmericasThis Edition First Published CopyrightDisclaimer TrademarksThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting Precautions and Instructions Safety PrecautionsESD Precautions About This ManualConventions Who should read this manual?Related Documentation NamingSoftware and Firmware Updates Chapter Introduction Product OverviewProduct Introduction Controller Box EnclosureFront Side Rear SideSR Components LCD PanelController Board JP1 and JP13 Connector Type Label DescriptionController Board Front InterfacesConnector Type Label Description Separately Purchased Accessory Items SR Accessory Items4 I2C Signal Compatible Cables Power ConnectorBattery Backup Unit BBU Optional ItemsPower Supply Requirements Environmental RequirementsDaughter Board Expansion SR Controller Monitoring LED IndicatorsCooling Requirements 1 I2C BusAudible Alarms This page is intentionally left blank Installation Overview Chapter InstallationInstallation Prerequisites General ConsiderationsStatic-free Installation Hardware Installation PreparationTools or Equipment Needed for Installing the Subsystem Planning Before InstallationUnpacking the Controller General Installation ProcedureAccessing the Controller Board OverviewRemoving and Replacing the Chassis Top Cover Memory Module Installation Dimm Module Installation ProcedureSelecting the DIMMs About the First BBU Installation Battery Backup Unit BBU InstallationRemove the Battery Connector Cap BBU Installation ProcedureInstall the Battery Charger Board Daughter Board Installation About Daughter Board InstallationDaughter Board Installation Procedure Daughter Board Installation Controller Monitoring Overview Chapter Controller MonitoringPWR Status-indicating LEDsAudible Alarm Default Threshold ValuesI2C Port Enclosure Monitoring I2C Port Enclosure Monitoring Chapter Controller Connections Operation 1 I/O Channel ConfigurationSentinelRAID Connection Host ConnectionDrive Connection SR 170 TopologiesScsi Termination Unique IDsSR 170 Topologies Dual Host Connection Dual Host ConnectionExpansion Controller IntegrationPower Connection Connecting RS-232C Terminal EmulationOther Connections Check List Power OnLCD Screen Power On SequenceStop I/O access to the system Disconnect the host Power Off ProcedurePower Off Procedure Controller Maintenance Overview Chapter Controller MaintenanceAbout Controller Maintenance User Serviceable ComponentsWhen should a Dimm module be replaced? Dimm Module Replacement ProcedureReplacing a failed Dimm Module Replacing a failed Dimm Module Replacing a Failed Optional BBU Module About BBU MaintenanceOnce the controller board has pack from the charger board BBU Charger Board Replacement Daughter Board MaintenanceAbout Daughter Board Maintenance Replacing a Daughter BoardRemove the Daughter Board Retention Screws This page is intentionally left blank Flexible Configuration Appendix a SentinelRAID FeaturesUser-friendly Configuration Utilities SCSI-320 I/O ChannelsController Architecture Other Fault Tolerant FeaturesGlobal and Local Spares Hot-swapping of DrivesController Chassis RAID Levels SupportedThis page is intentionally left blank Appendix B Hardware Specifications ConfigurationSpecification Feature RAID Management Controller ArchitectureFault Tolerance Specification Size Technical SpecificationsDescription Specification SoftwareController Specifications Technical Specifications Problem Appendix C Hardware TroubleshootingProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Accessories Appendix D Spare Parts and AccessoriesAccessory Part Number Description Spare PartsAccessories Controller Main Board Interfaces Appendix E Connectors and Jumper IdentificationController Main Board Interface Descriptions Label Connector NameLED Jumper Pin Outs COM Port Pin OutsPin Description Symbol Type Description J3 I2C PortPin Pin Name Symbol Parameter Rating Unit J1 Battery ConnectorTTL Device Parameters PinIFT-9012 RS-232C Extension Cable IFT- 9011 Null ModemIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank