SentinelRAID 170 Installation and Hardware Reference Manual
NOTE:
It is recommended to use the embedded terminators on host or drive channels by setting DIP switches, and then installing an external terminator on the other end of your SCSI cable. If a drive fails, data traffic will remain unaffected. Please note of the following:
1.Refer to the installation documents that came with your drives for information on jumper settings.
2.Set a unique SCSI ID address on each drive. Avoid ID 7 – this is a default reservation for the controller. In redundant controller mode, each of the two controllers takes an ID on each SCSI bus. The combination can be ID 6 and ID 7 or ID 8 and ID 9.
4.4.Other Connections
4.4.1Power Connection
The power input and connection of the controller is exactly the same as those for hard disk drives. Be sure to connect both connectors. The power connection is shown in Figure
Figure 4-4: PSU Connection
4.4.2 Connecting RS-232C Terminal Emulation
The controller can be configured via a PC running a
Connect COM 1 to the included null modem
Other Connections |