Infortrend SentinelRAID 170 320ML/sec SCSI-to-SCSI RAID Controller Controller Specifications

Page 63

 

 

Appendix B: Hardware Specifications

 

 

 

 

B.6.3 Controller Specifications

 

 

 

 

 

 

 

Description

Specification

 

 

 

 

 

 

Cache memory

At least 128MB, up to 1GB, PC-133

 

 

 

SDRAM DIMM socket x1

 

 

 

 

 

 

Firmware

Resides in 2MB Flash memory

 

NVRAM

32KB

 

 

Devices per Channel

SCSI: up to 15 SCSI devices

 

 

 

 

 

 

Supported Device Types

Synchronous or asynchronous

 

RAID Levels Supported

0, 1(0+1), 3, 5, 10, 30, 50, JBOD and

 

 

 

non-RAID disk spanning

 

 

 

 

 

 

SCSI Connectors

68-pin high-density connectors (x 4) on

 

 

base module

 

 

 

 

 

 

SCSI Cables

Up to 12 meters with low-voltage

 

 

differential

 

 

 

 

 

 

Serial Port

20-pin box header for COM1 & COM2

 

 

 

 

 

Ethernet Port

10/100M

 

LCD Panel

Yes

 

 

LED and Push-button Interface

Yes

 

 

 

 

 

 

Board Connectors

160-pin male docking connectors (x 2)

 

 

on main board (I-PEX model number

 

 

 

T80043-160T); connects main board to

 

 

 

main board backplane, integrating

 

 

 

SCSI/Fibre channels, redundant

 

 

 

controller features, RS-232C COM-1

 

 

 

and COM-2, battery connector signal,

 

 

 

on-board alarm, external LCD module,

 

 

 

SAF-TE status inputs, Ethernet port, I2C

 

 

 

port and drive failure indication

 

 

 

interface

 

 

Table B-8: Controller Specifications

 

 

Technical Specifications

B-5

Image 63
Contents 320MB/sec SCSI-to-SCSI RAID Controller Installation and Hardware Reference ManualAmericas Contact InformationAsia Pacific International Headquarters ChinaTrademarks CopyrightThis Edition First Published DisclaimerThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting About This Manual Safety PrecautionsPrecautions and Instructions ESD PrecautionsNaming Who should read this manual?Conventions Related DocumentationSoftware and Firmware Updates Chapter Introduction Product OverviewProduct Introduction Rear Side EnclosureController Box Front SideSR Components LCD PanelController Board JP1 and JP13 Connector Type Label DescriptionController Board Front InterfacesConnector Type Label Description Separately Purchased Accessory Items SR Accessory ItemsOptional Items Power Connector4 I2C Signal Compatible Cables Battery Backup Unit BBUPower Supply Requirements Environmental RequirementsDaughter Board Expansion 1 I2C Bus LED IndicatorsSR Controller Monitoring Cooling RequirementsAudible Alarms This page is intentionally left blank General Considerations Chapter InstallationInstallation Overview Installation PrerequisitesPlanning Before Installation Hardware Installation PreparationStatic-free Installation Tools or Equipment Needed for Installing the SubsystemUnpacking the Controller General Installation ProcedureAccessing the Controller Board OverviewRemoving and Replacing the Chassis Top Cover Memory Module Installation Dimm Module Installation ProcedureSelecting the DIMMs About the First BBU Installation Battery Backup Unit BBU InstallationRemove the Battery Connector Cap BBU Installation ProcedureInstall the Battery Charger Board Daughter Board Installation About Daughter Board InstallationDaughter Board Installation Procedure Daughter Board Installation Controller Monitoring Overview Chapter Controller MonitoringPWR Status-indicating LEDsAudible Alarm Default Threshold ValuesI2C Port Enclosure Monitoring I2C Port Enclosure Monitoring Host Connection 1 I/O Channel ConfigurationChapter Controller Connections Operation SentinelRAID ConnectionUnique IDs SR 170 TopologiesDrive Connection Scsi TerminationSR 170 Topologies Dual Host Connection Dual Host ConnectionExpansion Controller IntegrationPower Connection Connecting RS-232C Terminal EmulationOther Connections Check List Power OnLCD Screen Power On SequenceStop I/O access to the system Disconnect the host Power Off ProcedurePower Off Procedure User Serviceable Components Chapter Controller MaintenanceController Maintenance Overview About Controller MaintenanceWhen should a Dimm module be replaced? Dimm Module Replacement ProcedureReplacing a failed Dimm Module Replacing a failed Dimm Module Replacing a Failed Optional BBU Module About BBU MaintenanceOnce the controller board has pack from the charger board Replacing a Daughter Board Daughter Board MaintenanceBBU Charger Board Replacement About Daughter Board MaintenanceRemove the Daughter Board Retention Screws This page is intentionally left blank SCSI-320 I/O Channels Appendix a SentinelRAID FeaturesFlexible Configuration User-friendly Configuration UtilitiesHot-swapping of Drives Other Fault Tolerant FeaturesController Architecture Global and Local SparesController Chassis RAID Levels SupportedThis page is intentionally left blank Appendix B Hardware Specifications ConfigurationSpecification Feature RAID Management Controller ArchitectureFault Tolerance Software Technical SpecificationsSpecification Size Description SpecificationController Specifications Technical Specifications Problem Appendix C Hardware TroubleshootingProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Spare Parts Appendix D Spare Parts and AccessoriesAccessories Accessory Part Number DescriptionAccessories Controller Main Board Interfaces Appendix E Connectors and Jumper IdentificationController Main Board Interface Descriptions Label Connector NameLED Jumper Pin Outs COM Port Pin OutsPin Description Symbol Type Description J3 I2C PortPin Pin Name Pin J1 Battery ConnectorSymbol Parameter Rating Unit TTL Device ParametersIFT-9012 RS-232C Extension Cable IFT- 9011 Null ModemIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank