Infortrend 170 manual Controller Main Board Interface Descriptions, Label Connector Name

Page 72

SentinelRAID 170 Installation and Hardware Reference Manual

E.2. Controller Main Board Interface Descriptions

Label

Connector Name

 

 

JP1 and JP13

Daughter board connectors

 

 

JP6 and JP11

Battery charger board connector

 

 

JP2, JP3, and JP4

LED connectors

 

 

JP5

Not Mask Interrupted (NMI)

 

 

JP7

Reset

 

 

JP8

Loop-back test

 

 

JP9

GAL

 

 

JP10

LCD type selection

 

 

JP14

LCD connector

 

 

JP19

Restore firmware default

 

 

JP22

Front panel fan status detect

 

 

CH0, CH1, CH2 and CH3

SCSI-320 connectors

 

 

J3

I2C connector

 

 

J1

Battery connector

 

 

JP16 and JP17

COM1 and COM2 connector

 

 

JP20

SCSI terminators

 

 

JP23

RJ-45 Ethernet connector

 

 

E-2

Controller Main Board Interface Descriptions

Image 72
Contents Installation and Hardware Reference Manual 320MB/sec SCSI-to-SCSI RAID ControllerContact Information Asia Pacific International HeadquartersChina AmericasCopyright This Edition First PublishedDisclaimer TrademarksThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting Safety Precautions Precautions and InstructionsESD Precautions About This ManualWho should read this manual? ConventionsRelated Documentation NamingSoftware and Firmware Updates Chapter Introduction Product OverviewProduct Introduction Enclosure Controller BoxFront Side Rear SideSR Components LCD PanelController Board Connector Type Label Description JP1 and JP13Interfaces Controller Board FrontConnector Type Label Description SR Accessory Items Separately Purchased Accessory ItemsPower Connector 4 I2C Signal Compatible CablesBattery Backup Unit BBU Optional ItemsPower Supply Requirements Environmental RequirementsDaughter Board Expansion LED Indicators SR Controller MonitoringCooling Requirements 1 I2C BusAudible Alarms This page is intentionally left blank Chapter Installation Installation OverviewInstallation Prerequisites General ConsiderationsHardware Installation Preparation Static-free InstallationTools or Equipment Needed for Installing the Subsystem Planning Before InstallationGeneral Installation Procedure Unpacking the ControllerAccessing the Controller Board OverviewRemoving and Replacing the Chassis Top Cover Memory Module Installation Dimm Module Installation ProcedureSelecting the DIMMs Battery Backup Unit BBU Installation About the First BBU InstallationBBU Installation Procedure Remove the Battery Connector CapInstall the Battery Charger Board Daughter Board Installation About Daughter Board InstallationDaughter Board Installation Procedure Daughter Board Installation Chapter Controller Monitoring Controller Monitoring OverviewStatus-indicating LEDs PWRAudible Alarm Default Threshold ValuesI2C Port Enclosure Monitoring I2C Port Enclosure Monitoring 1 I/O Channel Configuration Chapter Controller Connections OperationSentinelRAID Connection Host ConnectionSR 170 Topologies Drive ConnectionScsi Termination Unique IDsSR 170 Topologies Dual Host Connection Dual Host ConnectionController Integration ExpansionPower Connection Connecting RS-232C Terminal EmulationOther Connections Power On Check ListPower On Sequence LCD ScreenPower Off Procedure Stop I/O access to the system Disconnect the hostPower Off Procedure Chapter Controller Maintenance Controller Maintenance OverviewAbout Controller Maintenance User Serviceable ComponentsWhen should a Dimm module be replaced? Dimm Module Replacement ProcedureReplacing a failed Dimm Module Replacing a failed Dimm Module About BBU Maintenance Replacing a Failed Optional BBU ModuleOnce the controller board has pack from the charger board Daughter Board Maintenance BBU Charger Board ReplacementAbout Daughter Board Maintenance Replacing a Daughter BoardRemove the Daughter Board Retention Screws This page is intentionally left blank Appendix a SentinelRAID Features Flexible ConfigurationUser-friendly Configuration Utilities SCSI-320 I/O ChannelsOther Fault Tolerant Features Controller ArchitectureGlobal and Local Spares Hot-swapping of DrivesRAID Levels Supported Controller ChassisThis page is intentionally left blank Appendix B Hardware Specifications ConfigurationSpecification Feature Controller Architecture RAID ManagementFault Tolerance Technical Specifications Specification SizeDescription Specification SoftwareController Specifications Technical Specifications Appendix C Hardware Troubleshooting ProblemProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Appendix D Spare Parts and Accessories AccessoriesAccessory Part Number Description Spare PartsAccessories Appendix E Connectors and Jumper Identification Controller Main Board InterfacesLabel Connector Name Controller Main Board Interface DescriptionsLED Jumper Pin Outs COM Port Pin OutsPin Description Symbol Type Description J3 I2C PortPin Pin Name J1 Battery Connector Symbol Parameter Rating UnitTTL Device Parameters PinIFT- 9011 Null Modem IFT-9012 RS-232C Extension CableIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank