Infortrend 170 Software, Technical Specifications, Specification Size, Description Specification

Page 62

SentinelRAID 170 Installation and Hardware Reference Manual

B.5. Software

Specification

Feature

 

 

In-band Text RAID

Yes (all major platforms)

Manager

 

 

 

RAIDWatch Manager

Yes (for any platform that supports Java 2.0 or

 

for Java Applet running via web browser)

 

 

LAN/WAN Support via

Yes

SNMP

 

Table B-5: Available Software

 

B.6. Technical Specifications

B.6.1 Physical Dimensions

 

 

Specification

 

Size

 

 

 

 

 

 

 

 

Controller Size in Frame

 

10.39 x 5.74 x 1.60 (L x W x H) inches

 

 

 

 

 

 

 

 

Main Board Height with

 

1.30-inch

 

 

Daughterboard

 

 

 

 

 

 

 

 

 

 

 

Table B-6: Controller Physical Dimensions

B.6.2 Environmental Specifications

 

 

 

 

 

Description

Specification

 

 

 

 

 

 

Operating Temperature

4 - 44°C

 

 

 

 

 

 

Operating Ambient Temperature

< 50°C

 

 

within Enclosure

 

 

 

 

 

 

 

 

Relative Humidity

10 - 95%, non-condensing

 

 

 

 

 

 

Operating Altitude

Sea level - 10,000 ft

 

 

 

 

 

 

MTBF

> 500,000 hours

 

 

 

 

 

 

 

Table B-7: Environmental Specifications

 

 

 

B-4

Software

Image 62
Contents Installation and Hardware Reference Manual 320MB/sec SCSI-to-SCSI RAID ControllerChina Contact InformationAsia Pacific International Headquarters AmericasDisclaimer CopyrightThis Edition First Published TrademarksThis device is in conformity with the EMC Table of Contents Controller Monitoring Appendix C Hardware Troubleshooting ESD Precautions Safety PrecautionsPrecautions and Instructions About This ManualRelated Documentation Who should read this manual?Conventions NamingSoftware and Firmware Updates Product Introduction Chapter IntroductionProduct Overview Front Side EnclosureController Box Rear SideController Board SR ComponentsLCD Panel Connector Type Label Description JP1 and JP13Interfaces Controller Board FrontConnector Type Label Description SR Accessory Items Separately Purchased Accessory ItemsBattery Backup Unit BBU Power Connector4 I2C Signal Compatible Cables Optional ItemsDaughter Board Expansion Power Supply RequirementsEnvironmental Requirements Cooling Requirements LED IndicatorsSR Controller Monitoring 1 I2C BusAudible Alarms This page is intentionally left blank Installation Prerequisites Chapter InstallationInstallation Overview General ConsiderationsTools or Equipment Needed for Installing the Subsystem Hardware Installation PreparationStatic-free Installation Planning Before InstallationGeneral Installation Procedure Unpacking the ControllerRemoving and Replacing the Chassis Top Cover Accessing the Controller BoardOverview Selecting the DIMMs Memory Module InstallationDimm Module Installation Procedure Battery Backup Unit BBU Installation About the First BBU InstallationBBU Installation Procedure Remove the Battery Connector CapInstall the Battery Charger Board Daughter Board Installation Procedure Daughter Board InstallationAbout Daughter Board Installation Daughter Board Installation Chapter Controller Monitoring Controller Monitoring OverviewStatus-indicating LEDs PWRI2C Port Enclosure Monitoring Audible AlarmDefault Threshold Values I2C Port Enclosure Monitoring SentinelRAID Connection 1 I/O Channel ConfigurationChapter Controller Connections Operation Host ConnectionScsi Termination SR 170 TopologiesDrive Connection Unique IDsSR 170 Topologies Dual Host Connection Dual Host ConnectionController Integration ExpansionOther Connections Power ConnectionConnecting RS-232C Terminal Emulation Power On Check ListPower On Sequence LCD ScreenPower Off Procedure Stop I/O access to the system Disconnect the hostPower Off Procedure About Controller Maintenance Chapter Controller MaintenanceController Maintenance Overview User Serviceable ComponentsReplacing a failed Dimm Module When should a Dimm module be replaced?Dimm Module Replacement Procedure Replacing a failed Dimm Module About BBU Maintenance Replacing a Failed Optional BBU ModuleOnce the controller board has pack from the charger board About Daughter Board Maintenance Daughter Board MaintenanceBBU Charger Board Replacement Replacing a Daughter BoardRemove the Daughter Board Retention Screws This page is intentionally left blank User-friendly Configuration Utilities Appendix a SentinelRAID FeaturesFlexible Configuration SCSI-320 I/O ChannelsGlobal and Local Spares Other Fault Tolerant FeaturesController Architecture Hot-swapping of DrivesRAID Levels Supported Controller ChassisThis page is intentionally left blank Specification Feature Appendix B Hardware SpecificationsConfiguration Controller Architecture RAID ManagementFault Tolerance Description Specification Technical SpecificationsSpecification Size SoftwareController Specifications Technical Specifications Appendix C Hardware Troubleshooting ProblemProblem Installed. Reinstall a Dimm module will usually solve This page is intentionally left blank Accessory Part Number Description Appendix D Spare Parts and AccessoriesAccessories Spare PartsAccessories Appendix E Connectors and Jumper Identification Controller Main Board InterfacesLabel Connector Name Controller Main Board Interface DescriptionsPin Description LED Jumper Pin OutsCOM Port Pin Outs Pin Pin Name Symbol Type DescriptionJ3 I2C Port TTL Device Parameters J1 Battery ConnectorSymbol Parameter Rating Unit PinIFT- 9011 Null Modem IFT-9012 RS-232C Extension CableIndex SentinelRAID 170 Installation and Hardware Reference Manual Index This page is intentionally left blank