Senco PC1108 operating instructions Troubleshooting, Probable Cause Remedy

Page 12

TROUBLESHOOTING

Symptom 1. Motor will not run or restart.

Power cord not plugged in.

Motor/Pressure switch in "OFF" position.

Motor thermal overload switch has tripped.

Fuse blown or circuit breaker has tripped.

Wrong gauge wire or length of extension cord.

Air tank pressure exceeds motor/ pressure switch "cut-in" pressure.

Pressure release valve on motor/ pressure switch has not unloaded pump head pressure.

Plug cord into grounded outlet.

Move switch to "ON" position.

Turn air compressor off, wait until motor is cool, then check motor circuit breaker.

Replace fuse or reset circuit breaker.

Check for proper fuse amperage.

Check for low voltage conditions.

Disconnect any other electrical appliances from circuit or operate air compressor on its own branch circuit.

Check chart on page #10 for proper gauge wire and cord length.

Motor will start automatically when air tank pressure drops below "cut-in" pressure of motor/pressure switch.

Bleed the line by moving the switch to the "OFF" position.

Defective motor, motor capacitor, motor/

Contact Senco Customer Service.

pressure switch, or check valve.

 

Symptom 2. When in the "ON" position, motor runs continuously.

PROBABLE CAUSE

Motor/Pressure switch does not shut off motor when air compressor reaches "cut-out" pressure and safety relief valve activates.

Air compressor is incorrectly sized.

REMEDY

Move the motor/pressure switch to the "OFF" position. If the motor doesn't shut off, unplug the air compressor. If the electrical contacts are welded together, replace the pressure switch.

Limit the air pressure to the capacity of the air compressor. Either use a smaller tool or a larger air compressor.

Symptom 3. Air continues to leak at motor/pressure switch release valve after motor stops.

PROBABLE CAUSE

REMEDY

Defective pilot valve, the check valve is stuck open.

Remove, clean or replace.

12

Image 12
Contents Operating Instructions Table of Contents Safety Alert IntroductionInspection Safety Warnings Hazard Potential Consequence Prevention RiskElectric Shock ElectrocutionExplosion or Fire BurstingHazard Potential Consequence Prevention Risk to BreathingBurns FlyingHazard Potential Consequence Prevention Risk from Moving PartsNegligence AIR Compressor DamageCompressor Features Wheel Preparation Initial SET-UPLocation ElectricalMaintenance OperationTroubleshooting Probable CauseRemedy Probable Cause RemedySymptom 5. Air leaks from safety relief valve Symptom 10. Air compressor not making enough air Specifications Senco PCSenco Compressor and Parts Warranty Compresseurdaire eléctrique PC1108 Table DES Matières Mises EN Garde DE SécuritéCaractéristiques DU Compresseur Alertes Pour LA Sécurité Mises EN Garde DE Sécurité Commotion Électrique OU D’ÉLECTROCUTIONCompresseur D’AIR Conséquences Potentielles Prévention Risque D’EXPLOSIONOU D’INCENDIE RisqueConséquences Potentielles Prévention Risque ’INHALATIONRisque DE Brûlure ’OBJETSConservez CES Instructions Caractéristiques DU Compresseur Caractéristiques DU Compresseur Emplacement PréparationMise EN Œuvre Initiale AvertissementFonctionnement Liste DE Vérifications PréliminairesDémarrage CoupureDépannage Cause ProbableRemède Cause Probable RemèdeSymptôme 5 L’air fuit au niveau de la soupape de sûreté Symptôme 11 Humidité dans l’air en sortie Spécifications Garantie Senco Pour LE Compresseur ET LES Pièces Instruccione de Operación Indice Introducción ¡AVISO DE SeguridadInspección Medidas DE Seguridad Riesgo Consecuencia Potencial Prevención Riesgo DEElectrochoque ElectrocuciónIncendio EstallidoRiesgo Potential Consequence Prevención Riesgo Para LAS Vias RespiratoriasQuemaduras Riesgo DE SER¡GUARDE Estas Instrucciones Características DEL Compresor Características DEL Compresor Preparación Montaje InicialEmplazamiento AdvertenciaFuncionamiento Lista DE Comprobación Antes DE LA Puesta EN MarchaCuadro DE Mantenimiento Localización Y Solución DE Averías Causa ProbableSolución Causa Probable SoluciónSíntoma 5. Escape de aire por la válvula de seguridad Síntoma 10. El compresor no produce suficiente aire Especificaciones MotorGarantia Senco Para EL Compresor Y LAS Piezas