Trane ZN510 Controller, Tracer manual Zone Sensor Specifications

Page 17

Zone Sensor Specifications

Part Number:

X13510606020

Description:

zSpace temperature (0.2 C resolution).

zExternal setpoint.

zON and CANCEL buttons.

zCommunication jack.

zVertical case with Trane logo.

Part Number:

X13510635010

Description:

zSpace temperature (0.2 C resolution).

zExternal setpoint.

zFan Switch (OFF and

AUTO).

zON and CANCEL buttons.

zCommunication jack.

zVertical case with Trane logo.

ON

17

Image 17
Contents WSHP-IOP-2 1998, American Standard Company Installation, OperationLiterature History Table of Contents Zone Sensor Placement Start-up ProcedureInstallation of New Units Power Up Sequence Power Up SequenceUnit Identification Tag Unit Identification TagCommunication Unit OperationPosition Damper Actuator or Generic Binary Output PowerBinary Outputs Output Overrides Binary input configurationsBinary Input Description Configuratio Contact Closure Open Occupancy Condensate OverflowGeneric Binary Input High and Low Pressure SwitchesDescription Communicated Request Hardwired State Result Compr Binary Outputs 24 VAC ComprAnalog Inputs Discharge Air Sensor Leaving Water Sensor CircuitOccupied setpoints Fan Mode InputLocal Setpoint Filter Maintenance Timer Fan Off DelayZone Sensor Internal and External Setpoint AdjustmentZone Sensor Setpoint OperationCommunication Jack Zone Sensor Features Fan Switch OptionalZone Sensor Specifications Compressor Minimum ON/OFF Timers Heating or Cooling Control Mode OperationHeating or Cooling Operation Capacity Unit Between 100% 50%Morning Warm Up Single and Dual Compressor OperationMaster Controller Data SharingConfiguration Red Service LED TroubleshootingYellow Service LED Green Status LEDPump Configurations Manual Output Testing the HeatTesting the Heat Pump Configurations Pump Operation for Systems with ZN510 Loop ControllerFan output does not energize Questionable Unit OperationNicated information Wait time expiresOutdoor air damper stays open Compressors not runningOutdoor air damper stays closed Diagnostic Fan Other Outputs DiagnosticsZN510 controller diagnostics Resetting Diagnostics Translating Multiple DiagnosticsCycling Power Rover Service ToolWiring Diagram Wiring Diagram Specifications Board Dimensions Hardware SpecificationsOperating Environment 32 to 140 F 0 to 60 C Agency ListingsDescription Terminals Function Binary InputsBinary Output J1-1 12 VA VAC RMS typical J1-2 J1-4 Binary Output J1-5 12 VA VAC RMS typical J1-6 J1-7