Trane Tracer, ZN510 Controller manual Unit Identification Tag

Page 6

Unit

Identification

Tag

Unit Identification Tag

The unit identification tag is factory mounted and provided for easy identification of an installed unit. It contains model number, tagging, and location information. See Figure 1.

The top portion of the unit identification tag remains permanently affixed to the unit for identity purposes. The bottom portion of the tag provides pertinent information that is removable to be placed on building plans or in the ZN510 IOP on page 33. This provides identification history about the unit’s location for quick reference.

These tags provide information about unit location, unit serial number, and NID (neuron identification number). The NID is similar to the serial number of the unit but is specific to the identification of the ZN510 Board. The location identification is a customer defined, clear English description, of the unit’s physical location. This is a 27 character description of the location. For example, if the location identification for a unit is “Conference Room 101”, the ZN510 and Rover (the Trane Comm 5 service tool) will recognize this clear English description so maintenance can be performed on the appropriate unit. If location identification is not defined, it will default to the unit serial number. This provides some information so the user has multiple references to the unit. The blank location is provided for field modification in case the unit is moved from the initial location.

Figure 1: Unit Identification Tag

Note: Fold and tear carefully along dashed removable line.

6

Image 6
Contents WSHP-IOP-2 Installation, Operation Literature History1998, American Standard Company Table of Contents Start-up Procedure Installation of New UnitsZone Sensor Placement Power Up Sequence Power Up SequenceUnit Identification Tag Unit Identification TagUnit Operation CommunicationPower Binary OutputsPosition Damper Actuator or Generic Binary Output Binary input configurations Binary Input Description Configuratio Contact Closure OpenOutput Overrides Condensate Overflow OccupancyHigh and Low Pressure Switches Description Communicated Request Hardwired State ResultGeneric Binary Input Analog Inputs 24 VAC ComprCompr Binary Outputs Discharge Air Sensor Leaving Water Sensor CircuitFan Mode Input Local SetpointOccupied setpoints Fan Off Delay Filter Maintenance TimerZone Sensor Internal and External Setpoint AdjustmentZone Sensor Setpoint OperationZone Sensor Features Fan Switch Optional Communication JackZone Sensor Specifications Heating or Cooling Operation Heating or Cooling Control Mode OperationCompressor Minimum ON/OFF Timers Capacity Unit Between 100% 50%Single and Dual Compressor Operation Morning Warm UpData Sharing Master ControllerConfiguration Yellow Service LED TroubleshootingRed Service LED Green Status LEDTesting the Heat Pump Configurations Manual Output Testing the HeatPump Configurations Pump Operation for Systems with ZN510 Loop ControllerNicated information Questionable Unit OperationFan output does not energize Wait time expiresCompressors not running Outdoor air damper stays openOutdoor air damper stays closed Diagnostics ZN510 controller diagnosticsDiagnostic Fan Other Outputs Cycling Power Translating Multiple DiagnosticsResetting Diagnostics Rover Service ToolWiring Diagram Wiring Diagram Operating Environment 32 to 140 F 0 to 60 C Hardware SpecificationsSpecifications Board Dimensions Agency ListingsBinary Output J1-1 12 VA VAC RMS typical J1-2 J1-4 Binary InputsDescription Terminals Function Binary Output J1-5 12 VA VAC RMS typical J1-6 J1-7