Trane ZN510 Controller Hardware Specifications, Specifications Board Dimensions, Agency Listings

Page 31

Hardware Specifications

Specifications

Board Dimensions

Height:

4” (102 mm)

 

 

 

Width:

5-1/2”

(140 mm)

 

 

 

Depth:

2-1/4”

(57mm)

 

 

 

Operating Environment 32 to 140 F (0 to 60 C)

5 to 95% non-condensing

Storage Environment

-40 to 185 F (-40 to 85 C) 5 to 95% non-condensing Power Requirements

18 to 32 VAC (24 VAC nominal)

50 or 60 Hz

300 mA

Agency Listings

UL and CUL 916 Energy

Management System

Agency Compliance

IEC 1000-4-2 (ESD), IEC 1000-4-4

(EFT), IEC 1000-4-5 (Surge), FCC Part 15, Class A.

Input/Output Summary

zThree binary inputs.

zSix binary outputs only five are used.

zFive analog inputs.

zTimed override ON and CANCEL.

zComm5 communication.

Heat sink is mounted to the top

of the control box

4”

5 1/2”

Figure 10: ZN510 Circuit Board

31

Image 31
Contents WSHP-IOP-2 Literature History Installation, Operation1998, American Standard Company Table of Contents Installation of New Units Start-up ProcedureZone Sensor Placement Power Up Sequence Power Up SequenceUnit Identification Tag Unit Identification TagCommunication Unit OperationBinary Outputs PowerPosition Damper Actuator or Generic Binary Output Binary Input Description Configuratio Contact Closure Open Binary input configurationsOutput Overrides Occupancy Condensate OverflowDescription Communicated Request Hardwired State Result High and Low Pressure SwitchesGeneric Binary Input Discharge Air Sensor Leaving Water Sensor Circuit 24 VAC ComprCompr Binary Outputs Analog InputsLocal Setpoint Fan Mode InputOccupied setpoints Filter Maintenance Timer Fan Off DelaySetpoint Operation Internal and External Setpoint AdjustmentZone Sensor Zone SensorCommunication Jack Zone Sensor Features Fan Switch OptionalZone Sensor Specifications Capacity Unit Between 100% 50% Heating or Cooling Control Mode OperationCompressor Minimum ON/OFF Timers Heating or Cooling OperationMorning Warm Up Single and Dual Compressor OperationMaster Controller Data SharingConfiguration Green Status LED TroubleshootingRed Service LED Yellow Service LEDPump Operation for Systems with ZN510 Loop Controller Manual Output Testing the HeatPump Configurations Testing the Heat Pump ConfigurationsWait time expires Questionable Unit OperationFan output does not energize Nicated informationOutdoor air damper stays open Compressors not runningOutdoor air damper stays closed ZN510 controller diagnostics DiagnosticsDiagnostic Fan Other Outputs Rover Service Tool Translating Multiple DiagnosticsResetting Diagnostics Cycling PowerWiring Diagram Wiring Diagram Agency Listings Hardware SpecificationsSpecifications Board Dimensions Operating Environment 32 to 140 F 0 to 60 CBinary Output J1-5 12 VA VAC RMS typical J1-6 J1-7 Binary InputsDescription Terminals Function Binary Output J1-1 12 VA VAC RMS typical J1-2 J1-4