HP Server tc2110 manual Pin Narrow Scsi Port Connector Accessory Board, Position

Page 18

Chapter 2External Connectors

Pin Number

Signal

Pin

Signal

 

Description

Number

Description

 

 

 

 

34

+DB(11)

68

-DB(11)

 

 

 

 

50-Pin Narrow SCSI Port Connector – Accessory Board

Position 25

Position 1

 

Position 50

 

Position 26

 

 

SCSI Port Connector

 

 

50-Pin Narrow SCSI Port Connector Pinouts

 

 

 

Pin Number

 

Signal Description

Pin Number

 

Signal Description

 

 

 

 

 

 

1-11

 

Ground

37

 

Reserved

 

 

 

 

 

 

12

 

Reserved

38

 

Termpwr

 

 

 

 

 

 

13

 

Open

39

 

Reserved

 

 

 

 

 

 

14

 

Reserved

40

 

Ground

 

 

 

 

 

 

15-25

 

Ground

41

 

-ATN

 

 

 

 

 

 

26

 

-DB(0)

42

 

Ground

27

 

-DB(1)

43

 

-BSY

 

 

 

 

 

 

28

 

-DB(2)

44

 

-ACK

 

 

 

 

 

 

29

 

-DB(3)

45

 

-RST

30

 

-DB(4)

46

 

-MSG

 

 

 

 

 

 

31

 

-DB(5)

47

 

-SEL

 

 

 

 

 

 

32

 

-DB(6)

48

 

-C/D

33

 

-DB(7)

49

 

-REQ

 

 

 

 

 

 

34

 

-DB(P)

50

 

-I/O

 

 

 

 

 

 

35-36

 

Ground

 

 

 

 

 

 

 

 

 

12

Image 18
Contents HP Server tc2110 Operations and Maintenance Guide Audience Assumptions Contents Error! Bookmark not defined ContentsServer stops working hangs 105 109Controls and Indicators Front PanelAdditional Controls and Indicators Sleep LEDRear Panel Applying Power to the HP Server Connecting the Power CordsPowering-Up the Server Setting the input voltageConnecting the Power Cords Powering-Down the Server Connecting Power to Multiple-Server ConfigurationsSleep States Acpi Chapter Page External Connectors Mini-DIN PS/2 ConnectorsSerial Port Connector Parallel Port Connector USB ConnectorPin LVD Scsi Port Connector Low Voltage Differential Pin 1 LVD Scsi Connector MalePin Narrow Scsi Port Connector Accessory Board PositionStandard LAN Connector Page Installing and Configuring Opening and Closing the HP ServerRemoving the Left Side Cover Replacing the Left Side Cover Removing the Left Side CoverRemoving the Upper Bezel Replacing the Left Side CoverReplacing the Upper Bezel Removing the Upper Front BezelMass Storage Replacing the Upper BezelMass Storage Guidelines Mass Storage LocationsBoot Priority IDE Controller ConfigurationIDE Mass Storage Devices Scsi Controller Configuration Scsi Mass Storage DevicesIDE Mass Storage Additions Installing a Second Hard Disk Drive Drive Cage Mounted Scsi Mass Storage AdditionsReleasing the Retaining Clips Installing a Third Hard Disk Drive Tray Mounted Drive Cage MountingInstalling an Optional CD-ROM or DVD Drive Installing a Disk Drive Tray Mounted10. Installing an Optional CD-ROM or DVD Drive Installing an Optional Backup Tape Drive Memory Installation Guidelines Memory ModulesTools Required Installing Additional DIMMs 12. Dimm Locations on System Board Processor Removing DIMMsRemoving the Heat Sink and Cooling Fan 15. Removing Heat Sink and Cooling FanRemoving the Processor Replacing the ProcessorReplacing the Heat Sink and Cooling Fan 17. Replacing the ProcessorAccessory Boards Tested PCI BoardsIRQ Settings GuidelinesInstalling an Accessory Board Particular accessory board type 21. Removing the Slot Cover Connecting Peripheral Devices Removing Accessory BoardsUninterruptible Power Supply UPS Monitor, Keyboard, and MouseConfiguring the HP Server tc2110 Accessing the HP Startup CD-ROMHP Startup CD-ROM NOS Installation Bios Setup UtilityContents of the HP Startup CD-ROM DiagtoolsAccessing the Setup Utility Viewing the Summary Configuration ScreenMenu Bar Using the Setup Screens Changing the System Date and TimeSetting Boot Passwords Scsi Configuration Utility Diagnostics Power-On Self Test PostAfter Installing an Accessory No Error Messages DisplayedPost Error Messages General ChecksClearing the Cmos and Passwords Location of Configuration Switches HP Server Diagtools HP Diagtools CapabilitiesHP Toptools About Error MessagesAdvantages and Limitations of Hardware Diagnostics Some limitations areError Messages Power-On Self Test Post Error MessagesBeep Codes Maintenance and Troubleshooting Preventive Maintenance ProceduresTroubleshooting Tools Troubleshooting Other Support InformationTroubleshooting Checklist Bios Reset/Update/Recovery Bios ResetBios Update/Recovery Supervisor Password Password ProblemsClearing the Bios Configuration User PasswordConfiguration and Password Switch Location Operating System Not Found Message AppearsPower Problems Server Stops or Hangs While Starting UpVideo/Monitor Problems Configuration Problems Printer ProblemsKeyboard Does Not Work Mouse Does Not WorkFlexible Disk and Flexible Disk Drive Problems Flexible Disk Drive ProblemsEnvironmental problems result from CD-ROM Problems CD-ROM Drawer Will Not OpenCD-ROM Drive is Not Working Properly Scsi Problems Server Will Not Boot From a CD-ROM DiskScsi Controller Does Not Work At Initial Installation Scsi Device Does Not Work After Installation Scsi Device Stops WorkingProcessor Problems Memory ProblemsNetwork Interface Card embedded or PCI Problems LEDs are not lit on the NIC Replacing Parts Safety InformationService Tools Required Mass Storage Devices Removing the Flexible Disk DriveReplacing the Flexible Disk Drive Removing the CD-ROMReplacing the CD-ROM Removing the CD-ROMRemoving a Backup Tape Drive Replacing a Backup Tape DriveRemoving a Hard Disk Drive Tray Mounted Replacing a Hard Disk Drive Tray Mounted Removing Hard Disk Drive HDD and TrayRemoving a Hard Disk Drive Drive Cage Mounted DIMMs Replacing a Hard Disk Drive Drive Cage MountedReplacing DIMMs Removing DIMMs from System BoardDimm to Slot Alignment 10. Removing Heat Sink and Cooling Fan 11. Removing the Processor 12. Replacing the Processor 13. Replacing Heat Sink-Cooling Fan on the Processor Replacing Accessory Boards 14. Removing Slot Cover LatchSlot Cover Power Supply Removing the Power SupplyBattery Replacing the Power SupplyRemoving the Battery Replacing the Battery Chassis FanRemoving the Chassis Fan Replacing the Chassis Fan 19. Removing the Chassis FanSystem Board Removing the System BoardReplacing the System Board 20. Removing and Replacing the System BoardPage Parts Identification Exploded View Covers and BezelsExploded View Mass Storage Devices Exploded View Chassis Fan, Power Supply, and System Board Exploded View System Board Components Replaceable Parts List Cables and Part Numbers Power Cords KeyboardsPage Power Supply Specifications SpecificationsWeight and Dimensions EnvironmentalHardware Specifications IDESystem Board Components/Connectors 107 System Board LayoutPage Index AcpiKeyboards Part numbers Scsi ID ZIF
Related manuals
Manual 1 pages 3.34 Kb Manual 4 pages 49.92 Kb Manual 65 pages 57.66 Kb

Server tc2110 specifications

The HP Server tc2110 is a robust and versatile solution designed to meet the needs of small to medium-sized businesses looking for reliability and performance in their IT infrastructure. This server is built on the foundation of HP's renowned engineering, making it a trusted choice for organizations needing dependable server capabilities.

One of the standout features of the HP tc2110 is its scalability. With support for multiple processors, organizations can easily upgrade their server capabilities as their needs grow. This makes it an ideal choice for businesses that anticipate future expansion and require a server that can grow alongside them. The tc2110 supports various Intel Xeon processors, offering excellent processing power and efficiency.

Another significant characteristic of the tc2110 is its high capacity for memory. The server can support substantial RAM, which enhances its multitasking capabilities and allows it to handle demanding applications with ease. This memory capacity is complemented by the server's support for various storage options, including traditional hard drives and modern solid-state drives, enabling businesses to optimize performance and data access speeds according to their specific needs.

The HP Server tc2110 also emphasizes security features, which are critical for today’s evolving cybersecurity landscape. It includes advanced hardware security features such as Trusted Platform Module (TPM) and secure boot, ensuring that data is protected against unauthorized access and potential threats.

In addition to its impressive hardware capabilities, the tc2110 is designed with energy efficiency in mind. Its intelligent cooling technologies and power management features help reduce overall operational costs while maintaining optimal performance. This makes the server not only a powerful option but also a more environmentally friendly choice, aligning with the growing trend towards sustainable IT practices.

Connectivity is another key aspect of the HP tc2110. It offers multiple ports for network connections, ensuring seamless integration into existing IT infrastructures. This connectivity enhances communication between devices and provides businesses with the flexibility to adapt to new technology advancements with ease.

Overall, the HP Server tc2110 is a well-rounded server solution that combines performance, scalability, security, and energy efficiency. Whether for intensive applications, data management, or general computing tasks, the tc2110 stands out as a reliable choice for enterprises seeking to establish or enhance their IT environments. Its blend of features makes it a compelling option for organizations aiming to streamline operations while minimizing costs.