4.Verify that all four LED lights on the rear side of the electrical cabinet are on (PH1, PH2, PH3, Vacuum ON).

5.Wait for the printer to initialize.

NOTE: The printer will automatically start in diagnostic mode so you can purge the ink system.

When you first turn on the printer, you must set the voltage according to the country of installation.

Configure the voltage

1.From the front panel, enter the diagnostic menu and select Purge and Setup Menu > 3ph AC Volt Setup Menu to display a list of voltages.

2.Select the correct voltage according to the country of installation and press OK.

NOTE: Select the tri-phase nominal mains voltage (line to line) according to the Electrical Installation section of the Site Preparation checklist.

3.Press the Power enable button on the rear side of the printer. It should light up orange.

36 Chapter 6 Configure the electrical system

ENWW

Image 40
Contents HP Designjet L65500 Printer & HP Scitex LX Printer family Trademarks Table of contents Purge the ink system Prepare the printer Configure the electrical systemPrepare for printing Safety precautions General safety guidelinesHeat hazard Heavy substrate hazard Label Explanation Emergency stop buttons Installation guide overview Manpower requiredTools required for installation IntroductionInbox content L65500 onlyEnww Receive the shipment Unload the crateMove the printer over ramps Remove the crate packagingRemove the printer from the pallet Enww Lift the printer to a second floor using a crane Enww How to push the printer Set up the printer in the final positionChoose the final position Set up the printer in the final position Remove additional packaging Enww Enww Enww Enww Lower the feet Tri-phase AC Power Cord Connect the power cablesRequirements Tri-phase Power Cord attachment Tri-phase AC Power Cord Protective Earth conductors grounding Protective Earth attachmentConfigure the electrical system Install the fuses and power jumperInstall the fuses Install the power jumpersChoose delta or star Y configuration Heating Module ConfigurationCuring Module Configuration Check resistances Check connectionsPower on the printer Connect mains powerGround check Power on the printer Enww Turn power on Make sure that the printer is ready to be turned onConfigure the voltage Purge the ink system Purge the ISM tubesInk Supply Legend Enww Ink Supply Legend Enww Problems with the ink sensor value Enww Enww Fill the intermediate ink tanks Purge the tubes from the ISM to the printheads Enww Enww Enww Install the printhead cleaning roll Install the printhead cleaning roll and aerosol filtersPrepare the printer Install the printhead cleaning roll and aerosol filters Install the aerosol filters Manpower Tools Time Person T20, T30 Phillips screwdriver Enww Create a folder called OutJobs Enww Enww Configure the printer’s IP address Install the printheads Prepare for printingEnww Enww Callme@HP Setup Process Web Cam Installation Antivirus RegistrationLoad a substrate Connect the air supplyConfigure the RIP Customers RIP for use with the HP Designjet L65500 PrinterHP Scitex Onyx RIP Install the covers HP Scitex Caldera RIPInstall the covers Print the HP test images Print the HP test images Update the rate index Prepare the HP Internal Print Server Japan and Russia onlyChange the power settings Enww Configure the hard disk Set a blank screen saverEnable scheduled defragmentation Configure visual effects Configure the proxyInstall the HP Internal Print Server Enww Manually configure the printer’s IP address Select IPV4 Settings Select Config Method Enww Change the Windows Vista language Enww
Related manuals
Manual 16 pages 36.28 Kb