16.The printer displays OK when the configuration is set. Press any key to finish.
17.Switch the
NOTE: The printer performs a complete system check during start up. If a failure is detected during start up, follow the troubleshooting instructions in the Service Manual.
18.When the printer finishes initializing, select the preferred language in the front panel.
Use a syringe to purge the tubes from the ISM to the printheads
If the ink does not arrive to any of the air purgers, you must use a syringe to complete the purging operation. This procedure is only necessary if the ink did not arrive to one or more of the air purgers.
1.Fill the printhead pockets with paper or cloth to prevent spilled ink or dirt from dirtying the printhead interconnect contacts.
2.Use a cloth to remove the air purger to which ink did not arrive.
3.Insert an empty syringe into the ink port where you removed the air purger. Make sure the syringe plunger is pushed all the way into the syringe before you insert it into the ink port.
4.Enter the service menu and select Purge and Setup Menu > Purge Printer Tubes to perform the purge again.
5.The air will pass from the tubes into the syringe until the ink reaches the syringe. The syringe plunger will move by itself.
NOTE: If the syringe plunger does not move at all, pull it out no more than 1 mm. Otherwise, never manually pull the syringe plunger out.
6.When the purge operation is finished, put a cloth around the needle and remove the syringe quickly.
NOTE: Wait until the purge operation is completely finished before you remove the syringe.
7.Continue from step 6 of the previous procedure.
ENWW | 49 |