HP FET MULTIPLEXER E1351A/53A manual Certification

Page 5

Certification

Hewlett-Packard Company certifies that this product met its published specifications at the time of shipment from the factory. Hewlett- Packard further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Tech- nology (formerly National Bureau of Standards), to the extent allowed by that organization’s calibration facility, and to the calibration facilities of other International Standards Organization members.

Warranty

This Hewlett-Packard product is warranted against defects in materials and workmanship for a period of three years from date of ship- ment. Duration and conditions of warranty for this product may be superseded when the product is integrated into (becomes a part of) other HP products. During the warranty period, Hewlett-Packard Company will, at its option, either repair or replace products which prove to be defective.

For warranty service or repair, this product must be returned to a service facility designated by Hewlett-Packard (HP). Buyer shall pre- pay shipping charges to HP and HP shall pay shipping charges to return the product to Buyer. However, Buyer shall pay all shipping charges, duties, and taxes for products returned to HP from another country.

HP warrants that its software and firmware designated by HP for use with a product will execute its programming instructions when properly installed on that product. HP does not warrant that the operation of the product, or software, or firmware will be uninterrupted or error free.

Limitation Of Warranty

The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied prod- ucts or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or im- proper site preparation or maintenance.

The design and implementation of any circuit on this product is the sole responsibility of the Buyer. HP does not warrant the Buyer’s circuitry or malfunctions of HP products that result from the Buyer’s circuitry. In addition, HP does not warrant any damage that oc- curs as a result of the Buyer’s circuit or any defects that result from Buyer-supplied products.

NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. HP SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Exclusive Remedies

THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES. HP SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CON- TRACT, TORT, OR ANY OTHER LEGAL THEORY.

Notice

The information contained in this document is subject to change without notice. HEWLETT-PACKARD (HP) MAKES NO WAR-

RANTY OF ANY KIND WITH REGARD TO THIS MATERIAL, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WAR- RANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. HP shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This docu- ment contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photo- copied, reproduced, or translated to another language without the prior written consent of Hewlett-Packard Company. HP assumes no responsibility for the use or reliability of its software on equipment that is not furnished by HP.

Restricted Rights Legend

Use, duplication or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause in DFARS 252.227-7013.

Hewlett-Packard Company

3000 Hanover Street

Palo Alto, California 94304 U.S.A.

Rights for non-DOD U.S. Government Departments and Agencies are as set forth in FAR 52.227-19 (c) (1,2).

HP E1351A, E1353A 16-Channel FET Multiplexer Modules User’s Manual

Edition 4

Copyright © 1995 Hewlett-Packard Company. All Rights Reserved.

HP E1351A, E1353A 16-Channel FET Multiplexer Modules User’s Manual 5

Image 5
Contents Contents Understanding the HP E1351A/53A FET Multiplexer Modules Appendix C.HP E1351A/53A FET Multiplexer Error Messages HP E1351A/53A FET Multiplexer User’s Manual Contents Certification Documentation History According to ISO/IEC Guide 22 and EN July 20Page Business Reply Mail Page FET Multiplexer Module Description Using This ChapterMultimeter Connection Points Analog Bus ConnectorFET Multiplexer Module Block Diagram Output 70903OUTP on Switchbox and Scanning Voltmeter ConfigurationsDigital Bus and Triggering Initial Operation Programming LanguageConfiguring the HP E1351A/53A FET Multiplexer Modules Multiplexer Card Numbers Card Numbers for Single-Module SwitchboxesCard Numbers for Scanning Voltmeter Setting the Address SwitchSelecting the Interrupt Line Number Setting the Interrupt Line NumberCard ID Switch Setting the Card ID SwitchChannel FET Multiplexer Connector Pin-out Connecting User InputsSignal Conditioning Components/Current Shunts Adding Signal Conditioning Components/Current ShuntsWiring Guidelines Connecting Field WiringWiring a Terminal Module 10. Analog Bus and Digital Bus Connections Connecting Multimeters and Signal Generators11. Analog Bus and Digital Bus Cables Analog Bus and Digital Bus CablesPage Selecting Channels Using the HP E1351A/53A FET Multiplexer ModulesUsing the HP E1351A/53A FET Multiplexer Modules Chapter Matrix Commands Used in Chapter Multiplexer CommandsScanport None Connecting Switchbox Channels to Direct TerminalsCLOS? Closing Channels 02 and 09 for a Voltage Measurement Connecting Channels 02 and 10 for 4-Wire Ohms Measurement Example Making Voltage Measurements By Scanning Scanning a Range of Switchbox ChannelsScanning Channels 100 to 215 of a Two-Module Switchbox Example Making 4-Wire Ohms Measurements by Scanning Example Making 2-Wire Ohms Measurements by ScanningDownloading a Scan List Output 70904INIT Scanning a Switchbox without a Downloaded Scan ListOutput 70904STATOPERENAB Scanning a Switchbox with a Downloaded Scan ListConnecting the Analog Bus and Digital Bus Cables Scanning Voltmeter Configuration with HP E1326BTemperature Measurement Using a Thermocouple Using the HP E1351A/53A FET Multiplexer Modules Chapter Scanning with External Instruments Commands for Scanning Switchbox ChannelsUsing Scanning Trigger Sources Scanning Commands Trigger Sources Example Scanning With External Instruments Output 70914OUTP on Example Scanning Using Trig Out Event In PortsOutput 722TRIG Extdcvmem Fifo SCANMODE, Scanport and TRIGgerSOURce Dbus Example Scan Complete Monitor Using the Scan Complete BitScpi Command Format Command TypesCommon Command Format ROUTeSCANMODE Volt Scpi Command Reference Example Stopping a Scan with ABORt ABORtSubsystem Syntax Parameters COUNtComments Example Query Number of Scanning CyclesMONitorCARD Example Select Module #2 in a Switchbox for MonitoringDISPlay Mode Example Enabling the Monitor ModeCONTinuous INITiateExample Query Continuous Scanning State Example Enabling Continuous ScansSTATe OUTPut∙ Downloaded Scans The OUTPut subsystem does not work with Example Enabling Trig Out Port∙ Closing Channels To close ROUTeExample Closing Multiplexer Channels ∙ Query is Software Readback The ROUTeCLOSe? commandExample Query Multiplexer Channel Closure ∙ Opening Channels To openExample ∙ Query is Software Readback The ROUTeOPEN? commandOpening Multiplexer Channels Query Multiplexer Channel Open State∙ Scanning Operation With a valid channel list Example Scanning Using External InstrumentsExample Query Scan Mode Example Query Scan Port Example Selecting the Abus PortExample Set and Query the SETTling Time Example Setting 16 μsec SETTling TimeSTATus OPERationENABleExample Enable the Status Register Bit CDEScription? SYSTem∙ 16-Channel FET Multiplexer Module Description Example Reading the Description of Card #1 ModuleExample Reading the Model Number of a Card #1 Module Comments ∙ 16-Channel FET Multiplexer Module Model NumberExample Advancing Scan using the TRIGger Command ∙ Executing the TRIGgerIMMediate Command a channel listTRIGger IMMediate∙ Trig Out Port Shared by Switchboxes See the OUTPut command ∙ Enabling the Trigger Source The TRIGgerSOURce commandExample Query Trigger Source Example Scanning Using External TriggersScanning Using Bus Triggers ANSI/IEEE Standard Ieee 488.2 Common CommandsScpi Commands Quick Reference Description Command Quick ReferencePage Connectors Used P1 Maximum Offset Voltage Number of Slots Maximum Voltage Screw Terminal Wire Size Watts/SlotInput Impedance Power Requirements Power Off High to LowHP E1351A/53A FET Multiplexer Specifications Appendix a Register Addressing About This AppendixHP E1351A/53A Register-Based Programming Appendix B A16 Address Space Inside Command Module Or Mainframe A16 Address Space Outside Command Module Or MainframeRegister Descriptions Device Type Register Manufacturer ID Register Register Bit DescriptionsRegister module Status/Control Register Enable IRQ ENScan Control Register Scan Channel Delay RegisterContinuous Enable CNT EN Reset Pointer RST PTR Direct Channel Configuration Register Scan Channel Configuration RegisterA Tree Isolation Switch Disable A-D Valid Channel VLD C1 C0Direct Control Register Executing CommandsROUTe ROUTeCLOSe channellist is equivalent to the following HP E1351A/53A Register-Based Programming Appendix B Register-Based Programming for Maximum Speed Decimal code Appendix B HP E1351A/53A Register-Based Programming Table B-1. Multimeter Command and Parameter Opcodes Multimeter Command Parameter OpcodesFigure B-3. Configuring the Multimeter Error Code Cause Multimeter Register-Based Programming Error CodesHP E1351A/53A FET Multiplexer Error Messages HP E1351A/53A FET Multiplexer Error Messages Appendix C Laddr IndexHP E1351A/53A FET Multiplexer User’s Manual Index HP-IB HP E1351A/53A FET Multiplexer User’s Manual Index HP E1351A/53A FET Multiplexer User’s Manual Index HP E1351A/53A FET Multiplexer User’s Manual Index HP E1351A/53A FET Multiplexer User’s Manual Index