HP FET MULTIPLEXER E1351A/53A manual Multimeter Command Parameter Opcodes

Page 96

Multimeter

Command and

Parameter Opcodes

Table B-1 contains the multimeter command and parameter opcodes. The opcodes used to query the parameter settings are also included.

Table B-1. Multimeter Command and Parameter Opcodes

Multimeter

Command

Parameter

Value

 

Query

 

Query

Parameter

Opcode

Opcode

 

 

Opcode

 

Response

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measurement

04

00

DCV

 

05

 

parameter

Function

 

01

ACV

 

 

 

opcode

 

 

02

(4-wire) OHMS

 

 

 

 

Range

02

00

125 mV / 256 Ω

 

03

 

parameter

 

 

01

1V / 2.048 kΩ

 

 

 

opcode

 

 

02

8V / 16.384 kΩ

 

 

 

 

 

 

03

64V / 131 kΩ

 

 

 

 

 

 

04

300V / 1.048 MΩ

 

 

 

 

 

 

05

Autorange

 

 

 

 

 

 

 

 

 

 

 

 

Aperture Time

00

00

267 ms

 

01

 

parameter

 

 

01

16.7 ms

 

 

 

opcode

 

 

02

320 ms

 

 

 

 

 

 

03

20 ms

 

 

 

 

 

 

04

2.5 ms

 

 

 

 

 

 

05

100 μs

 

 

 

 

 

 

06

10 μs

 

 

 

 

 

 

 

 

 

 

 

 

Autozero

08

00

On

 

09

 

parameter

 

 

01

Off

 

 

 

opcode

 

 

02

Once

 

 

 

 

 

 

 

 

 

 

 

 

Offset

36

00

Off

 

37

 

parameter

Compensation

 

01

On

 

 

 

opcode

 

 

 

 

 

 

 

 

Trigger Source

06

00

Immediate

 

29

 

parameter

 

 

01

External

 

 

 

opcode

 

 

02

Hold

 

 

 

 

 

 

03 - 0A

TTL trigger lines

 

 

 

 

 

 

 

0 - 7

 

 

 

 

 

 

 

 

 

 

 

 

Trigger Count

39

<upper byte>

1 - 16,777,215

 

33

 

24-bit unsigned

 

 

<middle byte>

(1),(3)

 

 

 

number

 

 

<lower byte>

 

 

 

 

(2)

 

 

 

 

 

 

 

 

Trigger Delay

23

<upper byte>

0 - 16.777215s

 

31

 

24-bit unsigned

 

 

<middle byte>

(1)

 

 

 

number

 

 

<lower byte>

 

 

 

 

(2)

 

 

 

 

 

 

 

 

Voltmeter

40

8-bit binary number

0 - 7

 

41

 

8-bit binary number

Complete Signal

 

(7)

(TTL trigger lines)

 

 

 

 

Destination

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sample Count

38

<upper byte>

1 - 16,777,215

 

32

 

24-bit unsigned

 

 

<middle byte>

(1),(4)

 

 

 

number

 

 

<lower byte>

 

 

 

 

(2)

 

 

 

 

 

 

 

 

Sample Source

07

00

Immediate

 

30

 

parameter

 

 

01

Timer

 

 

 

opcode

 

 

02

Software

 

 

 

 

 

 

03

Control Register

 

 

 

 

 

 

 

 

 

 

 

Sample Period

10

<upper byte>

76μs - 65.534ms

11

 

16-bit unsigned

(5)

 

<lower byte>

(1)

 

 

 

number

 

 

 

 

 

 

 

(2)

 

 

 

 

 

 

 

 

Software Sample

35

—-

—-

—-

...

 

(6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trigger Arm

12

00

Un-armed

 

—-

 

—-

 

 

01

Armed

 

 

 

 

 

 

 

 

 

 

 

 

Trigger Immediate

13

—-

—-

—-

...

 

 

 

 

 

 

 

 

 

Send Error

15

—-

—-

—-

—-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table B-1 Continued on Next Page

96 HP E1351A/53A Register-Based Programming

Appendix B

Image 96
Contents Contents Understanding the HP E1351A/53A FET Multiplexer Modules Appendix C.HP E1351A/53A FET Multiplexer Error Messages HP E1351A/53A FET Multiplexer User’s Manual Contents Certification Documentation History July 20 According to ISO/IEC Guide 22 and ENPage Business Reply Mail Page Using This Chapter FET Multiplexer Module DescriptionAnalog Bus Connector Multimeter Connection PointsFET Multiplexer Module Block Diagram Switchbox and Scanning Voltmeter Configurations Output 70903OUTP onDigital Bus and Triggering Programming Language Initial OperationConfiguring the HP E1351A/53A FET Multiplexer Modules Card Numbers for Single-Module Switchboxes Multiplexer Card NumbersSetting the Address Switch Card Numbers for Scanning VoltmeterSetting the Interrupt Line Number Selecting the Interrupt Line NumberSetting the Card ID Switch Card ID SwitchConnecting User Inputs Channel FET Multiplexer Connector Pin-outAdding Signal Conditioning Components/Current Shunts Signal Conditioning Components/Current ShuntsConnecting Field Wiring Wiring GuidelinesWiring a Terminal Module Connecting Multimeters and Signal Generators 10. Analog Bus and Digital Bus ConnectionsAnalog Bus and Digital Bus Cables 11. Analog Bus and Digital Bus CablesPage Using the HP E1351A/53A FET Multiplexer Modules Selecting ChannelsUsing the HP E1351A/53A FET Multiplexer Modules Chapter Multiplexer Commands Matrix Commands Used in ChapterConnecting Switchbox Channels to Direct Terminals Scanport NoneCLOS? Closing Channels 02 and 09 for a Voltage Measurement Connecting Channels 02 and 10 for 4-Wire Ohms Measurement Scanning a Range of Switchbox Channels Example Making Voltage Measurements By ScanningScanning Channels 100 to 215 of a Two-Module Switchbox Example Making 2-Wire Ohms Measurements by Scanning Example Making 4-Wire Ohms Measurements by ScanningDownloading a Scan List Scanning a Switchbox without a Downloaded Scan List Output 70904INITScanning a Switchbox with a Downloaded Scan List Output 70904STATOPERENABScanning Voltmeter Configuration with HP E1326B Connecting the Analog Bus and Digital Bus CablesTemperature Measurement Using a Thermocouple Using the HP E1351A/53A FET Multiplexer Modules Chapter Commands for Scanning Switchbox Channels Using Scanning Trigger SourcesScanning with External Instruments Scanning Commands Trigger Sources Example Scanning With External Instruments Example Scanning Using Trig Out Event In Ports Output 70914OUTP onOutput 722TRIG Extdcvmem Fifo SCANMODE, Scanport and TRIGgerSOURce Dbus Using the Scan Complete Bit Example Scan Complete MonitorCommand Types Common Command FormatScpi Command Format ROUTeSCANMODE Volt Scpi Command Reference ABORt Subsystem SyntaxExample Stopping a Scan with ABORt COUNt ParametersComments Example Query Number of Scanning CyclesExample Select Module #2 in a Switchbox for Monitoring DISPlayMONitorCARD Example Enabling the Monitor Mode ModeINITiate CONTinuousExample Enabling Continuous Scans Example Query Continuous Scanning StateOUTPut STATe∙ Downloaded Scans The OUTPut subsystem does not work with Example Enabling Trig Out PortROUTe ∙ Closing Channels To close∙ Query is Software Readback The ROUTeCLOSe? command Example Closing Multiplexer ChannelsExample Query Multiplexer Channel Closure ∙ Opening Channels To open∙ Query is Software Readback The ROUTeOPEN? command ExampleOpening Multiplexer Channels Query Multiplexer Channel Open StateExample Scanning Using External Instruments ∙ Scanning Operation With a valid channel listExample Query Scan Mode Example Selecting the Abus Port Example Query Scan PortExample Setting 16 μsec SETTling Time Example Set and Query the SETTling TimeOPERationENABle Example Enable the Status Register BitSTATus SYSTem CDEScription?∙ 16-Channel FET Multiplexer Module Description Example Reading the Description of Card #1 ModuleComments ∙ 16-Channel FET Multiplexer Module Model Number Example Reading the Model Number of a Card #1 Module∙ Executing the TRIGgerIMMediate Command a channel list Example Advancing Scan using the TRIGger CommandTRIGger IMMediate∙ Enabling the Trigger Source The TRIGgerSOURce command ∙ Trig Out Port Shared by Switchboxes See the OUTPut commandExample Scanning Using External Triggers Scanning Using Bus TriggersExample Query Trigger Source Ieee 488.2 Common Commands ANSI/IEEE StandardCommand Quick Reference Scpi Commands Quick Reference DescriptionPage Maximum Voltage Screw Terminal Wire Size Watts/Slot Connectors Used P1 Maximum Offset Voltage Number of SlotsInput Impedance Power Requirements Power Off High to LowHP E1351A/53A FET Multiplexer Specifications Appendix a About This Appendix Register AddressingHP E1351A/53A Register-Based Programming Appendix B A16 Address Space Outside Command Module Or Mainframe A16 Address Space Inside Command Module Or MainframeRegister Descriptions Device Type Register Register Bit Descriptions Register moduleManufacturer ID Register Enable IRQ EN Status/Control RegisterScan Channel Delay Register Continuous Enable CNT EN Reset Pointer RST PTRScan Control Register Scan Channel Configuration Register Direct Channel Configuration RegisterA Tree Isolation Switch Disable A-D Valid Channel VLD C1 C0Executing Commands Direct Control RegisterROUTe ROUTeCLOSe channellist is equivalent to the following HP E1351A/53A Register-Based Programming Appendix B Register-Based Programming for Maximum Speed Decimal code Appendix B HP E1351A/53A Register-Based Programming Multimeter Command Parameter Opcodes Table B-1. Multimeter Command and Parameter OpcodesFigure B-3. Configuring the Multimeter Multimeter Register-Based Programming Error Codes Error Code CauseHP E1351A/53A FET Multiplexer Error Messages HP E1351A/53A FET Multiplexer Error Messages Appendix C Index LaddrHP E1351A/53A FET Multiplexer User’s Manual Index HP-IB HP E1351A/53A FET Multiplexer User’s Manual Index HP E1351A/53A FET Multiplexer User’s Manual Index HP E1351A/53A FET Multiplexer User’s Manual Index HP E1351A/53A FET Multiplexer User’s Manual Index