A

alarm cannot be silenced 39 alarm conditions 39 alarms, silencing 30 alarms, troubleshooting 39 authorized reseller 50 Auto-Bypass mode 28, 43

B

backup time, insufficient 42 batteries, care and storage 35 batteries, charging 23, 26

batteries, insufficient warning when low 41 batteries, replacing 35, 36

batteries, runtime

46

 

 

batteries, specifications

46

battery bracket 17, 18

 

battery circuit breaker

19

 

battery condition

40

 

 

Battery Fault LED, location

8

Battery Fault LED, troubleshooting 39

battery replacement notice

55

battery warranty

51

 

 

bezel, attaching

18, 25

 

bezel, removing

32

 

 

bracket, battery

17, 18

 

BSMI notice 55

 

 

 

buttons 6, 7

 

 

 

bypass is out of range

40

 

C

cables 53

 

 

 

Canadian notice

54

 

 

charging batteries

23, 26

 

circuit breakers, location

9, 10

circuit breakers, specifications

44

circuit breakers, switching off

25, 37

circuit breakers, switching on

22, 26

class A equipment

52

 

 

class B equipment

52

 

 

communications port, connecting 19

component identification

6, 7, 8, 9, 10

configuration of system 28 Configure button, location 7 Configure mode 28

Configure Mode On LED, location 8

connecting devices to UPS

22

connectors 6, 9, 10

 

contacting HP 50

 

cord retention clip locations

9

cord retention clips, connecting 23

D

Declaration of Conformity 53 devices, connecting 22 diagnostics 29 dimensions, ERM 44 dimensions, UPS 44 disposal, battery 55

E

electrical requirements 12

 

electronics module, replacing

33

electrostatic discharge 57

 

environmental specifications 47

ERM circuit breaker, turning off

25

ERM circuit breaker, turning on

26

ERM, configuring 28

 

ERM, connecting

26

 

ERM, identifying components

10

ERM, installing

24

 

ERM, replacing

37

 

European Union notice 54

 

F

FCC rating label 52

Federal Communications Commission (FCC) notice 52, 53

firmware, updating 38

frequent switching between battery and utility power 43

front panel buttons 7

front panel components 6, 7 front panel LEDs 8

Index 59

Image 59
Contents Part Number 351643-004A September 2007 Fourth Edition HP UPS R5500 User GuideAudience assumptions Contents Ordering spares Verifying the Repo port connection Powering down the UPSPower management software Before you contact HP HP contact information UPS spare parts list Hardware optionsDescription Component identificationUPS R5500 overview UPS front panelUPS front panel controls Powers up the UPS Starting power toFront panel is shown with the bezel removed LED description UPS front panel LED indicatorsRepo port UPS rear panelERM rear panel Tools and materials InstallationPrecautions Preparing to install the hardwareReadying the equipment Installing the mounting railsSelecting a site Installation Installation Tighten the hex nuts Installing the UPSPreparing the rails for integrated shipping Installation Removing the UPS battery bracket Installing the batteries Installation Installation Connecting the Repo port Connecting the ground bonding cable Ground bonding cable is not included Connecting the UPS to utility powerConnecting devices to the UPS Installation Starting power to the load Installing the ERMInstallation Installation Modes of operation Standby modeOperate mode UPS operationsExplanation when LED is illuminated Configuring the UPSConfigure mode Auto-Bypass modeAvailable settings Parameter Testing the LEDsVerifying the Repo port connection Silencing an audible alarmPowering down the UPS Power management software Power managementRemoving the UPS front bezel Removing the ERM front bezel MaintenanceReplacing the UPS electronics module Replacing the UPS option card Replacing the batteries Important battery safety informationBattery care and storage guidelines To replace the component, reverse the removal procedureUPS battery replacement procedure Replacing the ERM Replacing the UPSUpdating the UPS firmware 30? TroubleshootingLED and audible alarm troubleshooting Alarm Be silencedInput voltage is not within ±12 percent of nominal voltage Battery conditionGeneral alarm condition Bypass is out of rangeInsufficient warning of low batteries Internal UPS fault conditionLow battery shutdowns Input voltage is out of rangeRepo condition Site wiring conditionUPS does not provide the expected backup time Overload conditionUtility power condition UPS frequently switches between utility and battery powerUPS is in Auto-Bypass mode UPS is on batteryUPS input specifications SpecificationsUPS physical specifications ERM physical specificationsConfiguration setting VAC Available nominal output voltage Power protection specificationsVoltage specifications UPS model Nominal power Rating W Voltage settingOutput tolerance specifications Battery specificationsBattery runtime for NA/JPN model Battery runtime for Intl modelRepo port specifications Environmental specificationsDescription Spare part Number UPS spare parts listSpares Ordering sparesHardware options HP contact information Technical supportBefore you contact HP Pre-Failure Battery Warranty Warranty informationLimited warranty $250,000 Computer Load Protection GuaranteeFederal Communications Commission notice Regulatory compliance noticesRegulatory compliance identification numbers Cables ModificationsEuropean Union regulatory notice Canadian notice Avis CanadienJapanese notice Bsmi notice Battery replacement notice Power cord statement for Japan Taiwan battery recycling noticeGrounding methods to prevent electrostatic discharge Electrostatic dischargePreventing electrostatic discharge Acronyms and abbreviations Index Communications port, connectingInstallation instructions Repo port, connecting