Sterling SDA Series 25-100 specifications 15, 30, & 60 cfm Compact Dryers, 60 CFM, Description

Page 47

40

1

A0558000

CONTACTOR, IEC, 9A, 120VAC COIL

41

1

A0558078

RELAY, OVERLOAD, IEC, .32-1A

33

1

A0568936

FUSE, HEATERS, KTK-R-25

 

 

 

220VAC 1LOW HEAT

33

1

A0534047

FUSE, HEATERS, KTK-R-12

 

 

 

220VAC 1HIGH HEAT

33

1

A0534051

FUSE, HEATERS, KTK-R-30

 

 

 

208VAC 3LOW HEAT

33

3

A0534048

FUSE, HEATERS, KTK-R-15

 

 

 

208VAC 3HIGH HEAT

33

3

A0534051

FUSE, HEATERS, KTK-R-30

 

 

 

220VAC 3LOW HEAT

33

3

A0534047

FUSE, HEATERS, KTK-R-12

 

 

 

220VAC 3HIGH HEAT

33

3

A0534051

FUSE, HEATERS, KTK-R-30

 

 

 

230VAC 3LOW HEAT

33

3

A0534047

FUSE, HEATERS, KTK-R-12

 

 

 

230VAC 3HIGH HEAT

33

3

A0568936

FUSE, HEATERS, KTK-R-25

 

 

 

400VAC 3HIGH HEAT

33

3

A0534043

FUSE, HEATERS, KTK-R-7

 

 

 

400VAC 3LOW HEAT

33

3

A0534048

FUSE, HEATERS, KTK-R-15

 

 

 

460VAC 3HIGH HEAT

33

3

A0534042

FUSE, HEATERS, KTK-R-6

 

 

 

460VAC 3LOW HEAT

33

3

A0534048

FUSE, HEATERS, KTK-R-15

 

 

 

575VAC 3HIGH HEAT

33

3

A0534041

FUSE, HEATERS, KTK-R-5

 

 

 

575VAC 3LOW HEAT

33

3

A0534046

FUSE, HEATERS, KTK-R-10

 

 

 

60 CFM

Item

Qty.

Part #

Description

20

1

A0571659

SCHEMATIC, 60 CFM POWER

 

 

 

208VAC 3

24

1

A0571675

COMMON PARTS, 3POWER

28

1

 

FUSE, XFMR SECONDARY, LP-CC-10

31

1

 

TRANSFORMER, 208-230/460X120 PSF

32

2

 

FUSE, XFMR, PRIMARY, FNQ-R-1.4

40

1

 

CONTACTOR, IEC, 9A, 120VAC COIL

41

1

 

RELAY, OVERLOAD, IEC, 1.6-5A

 

 

 

220VAC 3

24

1

A0571675

COMMON PARTS, 3POWER

28

1

A0538067

FUSE, XFMR SECONDARY, LP-CC-9

31

1

A0558199

TRANSFORMER, 208-230/460X120 PSF

32

2

A0536892

FUSE, XFMR, PRIMARY, FNQ-R-1.25

40

1

A0558000

CONTACTOR, IEC, 9A, 120VAC COIL

41

1

A0558082

RELAY, OVERLOAD, IEC, 1.6-5A

 

 

 

230VAC 3

24

1

A0571675

COMMON PARTS, 3POWER

28

1

A0538067

FUSE, XFMR SECONDARY, LP-CC-9

31

1

A0558199

TRANSFORMER, 208-230/460X120 PSF

32

2

A0536892

FUSE, XFMR, PRIMARY, FNQ-R-1.25

40

1

A0558000

CONTACTOR, IEC, 9A, 120VAC COIL

41

1

A0558082

RELAY, OVERLOAD, IEC, 1.6-5A

 

 

 

400VAC 3

24

1

A0571675

COMMON PARTS, 3POWER

28

1

A0538060

FUSE, XFMR SECONDARY, LP-CC-5

31

1

A0558185

TRANSFORMER, 400X120 PSF

32

2

A0536889

FUSE, XFMR, PRIMARY, FNQ-R-0.6

40

1

A0558000

CONTACTOR, IEC, 9A, 120VAC COIL

41

1

A0558079

RELAY, OVERLOAD, IEC, 1-2.9A

 

 

 

460VAC 3

24

1

A0571675

COMMON PARTS, 3POWER

28

1

A0568921

FUSE, XFMR SECONDARY, LP-CC-4.5

31

1

A0558199

TRANSFORMER, 208-230/460X120 PSF

32

2

A0536889

FUSE, XFMR, PRIMARY, FNQ-R-0.6

15, 30, & 60 cfm Compact Dryers

47

Image 47
Contents SDA Series 15-60cfm Compact Dehumidifying Dryers If the Shipment is Not Complete Shipping InformationUnpacking and Inspection In the Event of Shipping DamageCHAPTER 2: FUNCTIONAL DESCRIPTION Table of ContentsCHAPTER 3 INSTALLATION CHAPTER 1 SAFETY15, 30, & 60 cfm Compact Dryers CHAPTER 5 MAINTENANCECHAPTER 6 TROUBLESHOOTING CHAPTER 7 APPENDIXSafety Symbols Used in this Manual Chapter 1 Safety1-1How to Use This Manual Dryer Safety Tags 1-2Safety Tag Information1-3Warnings and Precautions Read Operation and Installation ManualOperator Responsibility 1-4ResponsibilityGeneral Responsibility REMEMBER Reporting a Safety Defect Maintenance ResponsibilityWhat is desiccant? Chapter 2 Functional Description2-1Models Covered in This Manual 2-2General DescriptionElectrical Features 2-3Standard FeaturesFigure 1 Typical Dryer Air Flow Schematic Mechanical FeaturesController Features 2-5Safety Devices and Interlocks2-4Options Fail Safe Operation Safety Circuit StandardsSafety Device Lock-Outs 3-2Rigging and Placing the Dryer Chapter 3 Installation3-1Uncrating the Equipment DEW POINT POWER ON15, 30, & 60 cfm Compact Dryers 3-3Electrical Connections Floor Mount Models 3-4Setup ProceduresThree-PhaseModels Checking for Proper Blower RotationOptional Aftercooler 3-5Initial Start-upInstalling Water Lines Drying Hopper Air Trap ConsiderationsShutting Down the Dryer Auto-Tuningthe DryerIndicator Lights Chapter 4 Operation4-1Controller Description and Operation SwitchesPV SV Process Air Temperature ControllerIndicator IndicatorLit when Control Output 1 is on. The Out1 Lit when Control Output 2 is on. Not used inIndicator Setting the Process Air TemperatureIndicator Adjustment LevelEntering Operating Parameters to Select Modes IndicatorName DescriptionOptional Setting the High Dew Point AlarmProcess Air Dew Point Display Controller Operation 4-2Dryer Operation ProceduresAlarm Display Messages PROC BLWR HIGH TEMP VALVE MTRHEAT COOL 50 SYSTEM NORMAL Valve Motor Time-Out Blower Overload No AlarmsEvery week Chapter 5 Maintenance5-1Preventative Maintenance Schedule Every DayVacuuming 5-2Preventative MaintenanceFigure 9 Air Filter Location and Disassembly Servicing Process Air FiltersServicing the Dew Point Monitor 5-3Corrective MaintenanceCleaning with Compressed Air Symptoms of Worn DesiccantReplacing Worn Desiccant + FIRST AID +Figure 11 Required Desiccant Amounts 13X Type Figure 10 Desiccant Bed Location and DisassemblyWARNING! Hazardous electrical current present ProceduresReplacing the Process/Regeneration Heater If used as an after-Cooler 3 to 4 GPM @ 85F Replacing/Cleaning the Cooling CoilFigure 13 Cooling Coil Location and Disassembly Replacement Procedures15, 30, & 60 cfm Compact Dryers 8.Inset the four 10-32bolts back in place9.Turn the water to the cooling coil back on HIGH TEMP Chapter 6 Troubleshooting6-1Introduction Cause PROC BLWRAlarm Message HIGH TEMPCause VALVE MTRUsing a Thermocouple Alarm MessageWarranty Restrictions 7-1WarrantyChapter 7 Appendix Warranty SpecificationsAnnex B Information 7-2Technical SpecificationsCustomer Responsibilities High Pressure Peripheral Blower 7-3Drawings and DiagramsAftercooler Design Specifications Regeneration MoistureMake Up Air ExhaustHigh Pressure Peripheral Blower Figure 16 Low Heat Model 120F to 250F Air FlowAfter-Cooler Regeneration MoistureMake Up Air ExhaustMechanical Components 7-4Spare Parts ListDRYER SPARE PARTS LIST 15, 30, 60 cfm Models 15, 30, & 60 cfm Compact DryersHI-COREDESICCANT DRYER 15/30/60 CFM UNITS 15, 30, & 60 cfm Compact DryersDescription 15, 30, & 60 cfm Compact Dryers30 CFM Description 15, 30, & 60 cfm Compact Dryers60 CFM Description 15, 30, & 60 cfm Compact DryersA0571672 120V CONTROL COMMON PARTSCredit Returns 7-5Returned Material PolicyService Department 7-6Dryer Identification Serial Number Tag7-7Technical Assistance Warranty Returns15, 30, & 60 cfm Compact Dryers Contract Department