Figure 10: Desiccant Bed Location and Disassembly

Figure 10: Desiccant Bed Location and Disassembly

Valve & Air

Manifold Casting

 

Hollow

Desiccant

Desiccant

Tank

Assembly Rod

 

Gasket Figure 11: Required Desiccant Amounts (13X Type)

Regeneration

Heater

Wire Conduit

 

Assembly

Lower Air Manifold Casting

 

Caution! You should properly dispose of any discarded desiccant.

Consult local disposal regulations for more information.

11.Inspect each desiccant screen for tears or holes where desiccant burned-through. Replace desiccant can if needed.

12.After cleaning each chamber add the full amount of bead desiccant specified per bed. Amounts are listed in the Desiccant Amounts Table below. Tap on side of tank to settle desiccant. Smooth the top level, and finally add another layer of the remaining bead desiccant to the top. Make sure this layer is level and smooth.

13.Repeat the previous step for the other bed.

14.Inspect the gaskets. Replace if necessary.

15.Re-install all components and reconnect all of the wiring and hoses.

Figure 11: Required Desiccant Amounts (13X Type)

Dryer

8 x 12 bead Total

 

Model

Part no.

lbs.

 

Kg

15

W00018051

6.5

 

2.9

30

9.7

 

4.4

60

 

13.5

 

6.1

15, 30, & 60 cfm Compact Dryers

33

Image 33
Contents SDA Series 15-60cfm Compact Dehumidifying Dryers Unpacking and Inspection Shipping InformationIn the Event of Shipping Damage If the Shipment is Not CompleteCHAPTER 3 INSTALLATION Table of ContentsCHAPTER 1 SAFETY CHAPTER 2: FUNCTIONAL DESCRIPTIONCHAPTER 6 TROUBLESHOOTING CHAPTER 5 MAINTENANCECHAPTER 7 APPENDIX 15, 30, & 60 cfm Compact DryersChapter 1 Safety 1-1How to Use This ManualSafety Symbols Used in this Manual 1-3Warnings and Precautions 1-2Safety Tag InformationRead Operation and Installation Manual Dryer Safety Tags1-4Responsibility General ResponsibilityOperator Responsibility REMEMBER Reporting a Safety Defect Maintenance Responsibility2-1Models Covered in This Manual Chapter 2 Functional Description2-2General Description What is desiccant?Figure 1 Typical Dryer Air Flow Schematic 2-3Standard FeaturesMechanical Features Electrical Features2-5Safety Devices and Interlocks 2-4OptionsController Features Safety Circuit Standards Safety Device Lock-OutsFail Safe Operation Chapter 3 Installation 3-1Uncrating the Equipment3-2Rigging and Placing the Dryer POWER ON 15, 30, & 60 cfm Compact DryersDEW POINT 3-3Electrical Connections Three-PhaseModels 3-4Setup ProceduresChecking for Proper Blower Rotation Floor Mount ModelsInstalling Water Lines 3-5Initial Start-upDrying Hopper Air Trap Considerations Optional AftercoolerShutting Down the Dryer Auto-Tuningthe Dryer4-1Controller Description and Operation Chapter 4 OperationSwitches Indicator LightsPV SV Process Air Temperature ControllerLit when Control Output 1 is on. The Out1 IndicatorLit when Control Output 2 is on. Not used in IndicatorIndicator Setting the Process Air TemperatureAdjustment Level IndicatorName IndicatorDescription Entering Operating Parameters to Select ModesSetting the High Dew Point Alarm Process Air Dew Point DisplayOptional Controller Operation 4-2Dryer Operation ProceduresAlarm Display Messages HEAT COOL 50 SYSTEM NORMAL HIGH TEMP VALVE MTRValve Motor Time-Out Blower Overload No Alarms PROC BLWR5-1Preventative Maintenance Schedule Chapter 5 MaintenanceEvery Day Every weekFigure 9 Air Filter Location and Disassembly 5-2Preventative MaintenanceServicing Process Air Filters VacuumingCleaning with Compressed Air 5-3Corrective MaintenanceSymptoms of Worn Desiccant Servicing the Dew Point MonitorReplacing Worn Desiccant + FIRST AID +Figure 11 Required Desiccant Amounts 13X Type Figure 10 Desiccant Bed Location and DisassemblyProcedures Replacing the Process/Regeneration HeaterWARNING! Hazardous electrical current present Figure 13 Cooling Coil Location and Disassembly Replacing/Cleaning the Cooling CoilReplacement Procedures If used as an after-Cooler 3 to 4 GPM @ 85F8.Inset the four 10-32bolts back in place 9.Turn the water to the cooling coil back on15, 30, & 60 cfm Compact Dryers Chapter 6 Troubleshooting 6-1IntroductionHIGH TEMP Alarm Message PROC BLWRHIGH TEMP CauseUsing a Thermocouple VALVE MTRAlarm Message CauseChapter 7 Appendix 7-1WarrantyWarranty Specifications Warranty Restrictions7-2Technical Specifications Customer ResponsibilitiesAnnex B Information Aftercooler Design Specifications 7-3Drawings and DiagramsRegeneration MoistureMake Up Air Exhaust High Pressure Peripheral BlowerAfter-Cooler Regeneration MoistureMake Up Air Figure 16 Low Heat Model 120F to 250F Air FlowExhaust High Pressure Peripheral BlowerDRYER SPARE PARTS LIST 15, 30, 60 cfm Models 7-4Spare Parts List15, 30, & 60 cfm Compact Dryers Mechanical ComponentsHI-COREDESICCANT DRYER 15/30/60 CFM UNITS 15, 30, & 60 cfm Compact Dryers15, 30, & 60 cfm Compact Dryers 30 CFMDescription 15, 30, & 60 cfm Compact Dryers 60 CFMDescription A0571672 15, 30, & 60 cfm Compact Dryers120V CONTROL COMMON PARTS DescriptionCredit Returns 7-5Returned Material Policy7-7Technical Assistance 7-6Dryer Identification Serial Number TagWarranty Returns Service Department15, 30, & 60 cfm Compact Dryers Contract Department