Page 34
Replacing the Process/Regeneration Heater
The dehumidifying dryers utilize a single-phase Calrod-type heater element. This heater element is mounted in the center compartment in the desiccant beds. Although the replacement procedure is the same for each heater, the wattage varies by model, voltage, temperature range, etc.
WARNING! Hazardous electrical current present.
Disconnect and lock out power before you replace heater elements!
Figure 12: Process/Regeneration Heater Location and Disassembly
Valve & Air
Manifold Casting
| Hollow |
Desiccant | Desiccant |
Tank |
Assembly Rod
Gasket
Regeneration
Heater
Wire Conduit | |
Assembly | Lower Air Manifold Casting |
|
Procedures
1.Disconnect electrical power to the dryer.
2.Using a 1/8” Allen wrench, remove the 10-24 button head screws holding the top, back and side panels to the dryer frame.
3.Disconnect the plug for the valve motor, valve switch, and blower (15 only).
4.Remove the four (4) nuts at each corner of the top casting.
15, 30, & 60 cfm Compact Dryers | 34 |
Contents
SDA Series 15-60cfm Compact Dehumidifying Dryers
In the Event of Shipping Damage
Shipping Information
Unpacking and Inspection
If the Shipment is Not Complete
CHAPTER 1 SAFETY
Table of Contents
CHAPTER 3 INSTALLATION
CHAPTER 2: FUNCTIONAL DESCRIPTION
CHAPTER 7 APPENDIX
CHAPTER 5 MAINTENANCE
CHAPTER 6 TROUBLESHOOTING
15, 30, & 60 cfm Compact Dryers
1-1How to Use This Manual
Chapter 1 Safety
Safety Symbols Used in this Manual
Read Operation and Installation Manual
1-2Safety Tag Information
1-3Warnings and Precautions
Dryer Safety Tags
General Responsibility
1-4Responsibility
Operator Responsibility
REMEMBER
Maintenance Responsibility
Reporting a Safety Defect
2-2General Description
Chapter 2 Functional Description
2-1Models Covered in This Manual
What is desiccant?
Mechanical Features
2-3Standard Features
Figure 1 Typical Dryer Air Flow Schematic
Electrical Features
2-4Options
2-5Safety Devices and Interlocks
Controller Features
Safety Device Lock-Outs
Safety Circuit Standards
Fail Safe Operation
3-1Uncrating the Equipment
Chapter 3 Installation
3-2Rigging and Placing the Dryer
15, 30, & 60 cfm Compact Dryers
POWER ON
DEW POINT
3-3Electrical Connections
Checking for Proper Blower Rotation
3-4Setup Procedures
Three-PhaseModels
Floor Mount Models
Drying Hopper Air Trap Considerations
3-5Initial Start-up
Installing Water Lines
Optional Aftercooler
Auto-Tuningthe Dryer
Shutting Down the Dryer
Switches
Chapter 4 Operation
4-1Controller Description and Operation
Indicator Lights
Process Air Temperature Controller
PV SV
Lit when Control Output 2 is on. Not used in
Indicator
Lit when Control Output 1 is on. The Out1
Indicator
Adjustment Level
Setting the Process Air Temperature
Indicator
Indicator
Description
Indicator
Name
Entering Operating Parameters to Select Modes
Process Air Dew Point Display
Setting the High Dew Point Alarm
Optional
4-2Dryer Operation Procedures
Controller Operation
Alarm Display Messages
Valve Motor Time-Out Blower Overload No Alarms
HIGH TEMP VALVE MTR
HEAT COOL 50 SYSTEM NORMAL
PROC BLWR
Every Day
Chapter 5 Maintenance
5-1Preventative Maintenance Schedule
Every week
Servicing Process Air Filters
5-2Preventative Maintenance
Figure 9 Air Filter Location and Disassembly
Vacuuming
Symptoms of Worn Desiccant
5-3Corrective Maintenance
Cleaning with Compressed Air
Servicing the Dew Point Monitor
+ FIRST AID +
Replacing Worn Desiccant
Figure 10 Desiccant Bed Location and Disassembly
Figure 11 Required Desiccant Amounts 13X Type
Replacing the Process/Regeneration Heater
Procedures
WARNING! Hazardous electrical current present
Replacement Procedures
Replacing/Cleaning the Cooling Coil
Figure 13 Cooling Coil Location and Disassembly
If used as an after-Cooler 3 to 4 GPM @ 85F
9.Turn the water to the cooling coil back on
8.Inset the four 10-32bolts back in place
15, 30, & 60 cfm Compact Dryers
6-1Introduction
Chapter 6 Troubleshooting
HIGH TEMP
HIGH TEMP
PROC BLWR
Alarm Message
Cause
Alarm Message
VALVE MTR
Using a Thermocouple
Cause
Warranty Specifications
7-1Warranty
Chapter 7 Appendix
Warranty Restrictions
Customer Responsibilities
7-2Technical Specifications
Annex B Information
Regeneration MoistureMake Up Air Exhaust
7-3Drawings and Diagrams
Aftercooler Design Specifications
High Pressure Peripheral Blower
Exhaust
Figure 16 Low Heat Model 120F to 250F Air Flow
After-Cooler Regeneration MoistureMake Up Air
High Pressure Peripheral Blower
15, 30, & 60 cfm Compact Dryers
7-4Spare Parts List
DRYER SPARE PARTS LIST 15, 30, 60 cfm Models
Mechanical Components
15, 30, & 60 cfm Compact Dryers
HI-COREDESICCANT DRYER 15/30/60 CFM UNITS
30 CFM
15, 30, & 60 cfm Compact Dryers
Description
60 CFM
15, 30, & 60 cfm Compact Dryers
Description
120V CONTROL COMMON PARTS
15, 30, & 60 cfm Compact Dryers
A0571672
Description
7-5Returned Material Policy
Credit Returns
Warranty Returns
7-6Dryer Identification Serial Number Tag
7-7Technical Assistance
Service Department
Contract Department
15, 30, & 60 cfm Compact Dryers