HP Client Bridge M111 Operation Using 5 GHz Channels in the European Community, GHz Operation

Page 82

Regulatory information

2.4 GHz Operation

This device may be operated indoors or outdoors in all EU and EFTA countries using the 2.4 GHz band (Channels 1 - 13), except where noted below.

In France, this device may use the entire 2400 - 2483.5 MHz band (Channels 1 through 13) for indoor applications. For outdoor use, only the 2400 - 2454 MHz frequency band (Channels 1 through 9) may be used. For the latest requirements, see http://www.art-telecom.fr.

L'utilisation de cet equipement (2.4 GHz wireless LAN) est soumise à certaines restrictions: cet equipement peut être utilisé à l'interieur d'un batiment en utilisant toutes les frequences de 2400 a 2483.5 MHz (Chaine 1-13). Pour une utilisation en environnement exterieur, vous devez utiliser les frequencies comprises entre 2400 a 2454 MHz (Chaine 1-9). Pour les dernières restrictions, voir http://www.art-telecom.fr.

5 GHz Operation

This device requires the user or installer to properly enter the current country of operation in the 5 GHz Radio Configuration Window,

This device will automatically limit the allowable channels determined by the current country of operation. Incorrectly entering the country of operation may result in illegal operation and may cause harmful interference to other systems. The user is obligated to ensure the device is operating according to the channel limitations, indoor/outdoor restrictions and license requirements for each European Community country as described in this guide.

This device employs a radar detection feature required for European Community and EFTA country operation in the 5 GHz band. This feature is automatically enabled when the country of operation is correctly configured for any European Community or EFTA country. The presence of nearby radar operation may result in temporary interruption of operation of this device. The radar detection feature will automatically restart operation on a channel free of radar.

This device is restricted to indoor use when operated in EU and EFTA countries using the 5.15-5.35 GHz band (Channels 36, 40, 44, 48, 52, 56, 60 and 64). See the table below for the allowed 5 GHz channels in each band.

Operation Using 5 GHz Channels in the European Community

The user/installer must use the provided configuration utility to check the current channel of operation and make necessary configuration changes to ensure operation occurs in conformance with European National spectrum usage laws as described below and elsewhere in this guide.

Frequency

 

 

Maximum

Band (MHz)

Allowed Channels

Usage

EIRP (mW)

 

 

 

 

5150 - 5250

36, 40, 44, 48

Indoor use only

200

 

 

 

 

5250 - 5350

52, 56, 60, 64

Indoor use only

200

 

 

 

 

A-4

Image 82
Contents ProCurve 5400zl Switches HP ProCurve M111 Client Bridge Page HP ProCurve M111 Client Bridge Publication Number Contents Working with the M111 Field descriptions To assign a management address Resetting to factory defaults Regulatory informationViii Introduction Important terms About this guideProducts covered ConventionsCommands and program listings Example DescriptionKey features Introducing the M111 Client BridgeProfessional Installation Required Safety informationServicing Online documentation HP ProCurve Networking supportBefore contacting support Getting started Deploying the M111 Scenario 1 Connecting wired devices to a wireless networkOverview Configuration procedure Configure your computerConnect to the M111 Passwords Select Network DNSConfigure a station profile Connect the wired computers to the M111  The printer is configured with a static IP address Configure MAC cloning options Connect the wired device to the M111 Scenario 3 Connecting a serial device to a wireless network Configure the serial connection Getting started Getting started Working with the M111 802.1X certificates Certificate stores Certificate usage Management tool About passwordsStarting the management tool Customizing management tool settings Manager and Operator accountsPasswords Security policies SecurityWeb server IP address configurationAuto-refresh To configure IP addressing Radio configuration Wireless rangeWireless mode To configure the radioRestrict channels to Antenna selection Fast roaming threshold Fast roaming delta thresholdFast roaming threshold count Scan channel delayFast scan channel delay Minimum SNR thresholdTransmit power control Using station profiles to establish a wireless linkAdvanced wireless settings RTS thresholdWorking with the M111 To add or edit a station profile GeneralKey source Wireless securityWireless protection EAP methodWorking with the M111 Encryption type Quality of serviceViewing APs in the neighborhood Ap1certificate or ap2certificateAccess category Configuring Quality of Service QoSField descriptions Priority mechanisms QoS settings in a station profile802.1p Differentiated Services DiffServ Very-high, high, normal, low priorityTo define an IP QoS profile DisabledCreating IP QoS profiles Upstream DiffServ taggingProfile name Connecting serial devicesSettings Protocol Start port/ End portSerial port connector To connect a serial deviceMode Transmit timeoutIdle timeout Remote IP addressParity bit Drop wireless link when port 1 is connectedData bits Stop bitsTx kbytes DNS configurationConnection time Rx kbytesOverride dynamically assigned DNS servers DNS switch on server failureDynamically assigned DNS servers ServerHandling unsupported traffic DNS switch overEnable the Redirect unsupported traffic to option To forward unsupported trafficIP forwarding Cloning the address of a wired deviceLimitations Wireless access to the M111 when MAC cloning is active Enabling Ethernet MAC cloningSnmp agent UDP port Setting up management traffic interceptionManagement tool TCP port Select Management SnmpSnmp notifications UDP port Using filters to restrict wireless trafficEnable the Wireless traffic filters option Remote log UDP portAssigning a management address To assign a management addressSnmp V1/v2c communities AttributesV3 users Managing certificates Notification receiversInstall 802.1X Install TLS client certificatePassword 802.1X certificates802.1X Trusted CA certificates Certificate stores802.1X Manage TLS client certificates 802.1X Manage CA certificatesTrusted CA certificate store Installing a new CA certificateCA certificate import formats Certificate and private key store END CertificateSpecify the Pkcs #12 password Default installed private key/public key certificate chainsCertificate usage Changing the certificate assigned to a service About certificate warningsManual configuration file management Configuration file managementBackup configuration Restore configuration Reset configurationScheduled operations Software updates Select Install Performing an immediate software updatePerforming a scheduled update Enable Scheduled installWorking with the M111 Regulatory information Manufacturers FCC Declaration of Conformity Statement Countries of Operation & Conditions of Use Operation Using 5 GHz Channels in the European Community GHz OperationIndoor or outdoor use 1000 124, 128, 132, 136 Supported External Antennas5470 Antenna Band GHzDGT LPD Low Power Device Statement Resetting to factory defaults Using the management tool Using the Reset buttonHow it works Page Technology for better business outcomes