A1: | BASISPLAAT REGELING |
A2: | B A S I S U I T B R E I D I N G S K A A R T |
| REGELING | |
A3: | T H E R M I S C H E | B E V E I L I G I N G |
| COMPRESSOR 1 | |
A4: | T H E R M I S C H E | B E V E I L I G I N G |
| COMPRESSOR 2 | |
B1: | WATERINLAAT | (NTC - VOELER) |
B2: | WATERUITLAAT CIRCUIT 1 (NTC- |
| VOELER) | |
B3: | KOELTEMPERATUUR REGELING |
| VENTILATORSNELHEID (BATTERIJ 1) |
| (NTC-VOELER) | |
B5: | KOELTEMPERATUUR REGELING |
| VENTILATORSNELHEID (BATTERIJ 2) |
| (NTC-VOELER) | |
C1, C2: | CONDENSING-UNITS DOOR MOTOR |
| AANGEDREVEN VENTIILATOREN |
F1, F2: | ZEKERINGEN | |
F2: | ZEKERING SNELHEIDSREGELAAR |
FS: | DEBIETREGELAAR | |
FSC: | SNELHEIDSREGELING VENTILATOR |
HP: | H O G E D R U K R E G E L A A R |
| ( A U T O M A T I S C H E H E R S T A R T ) |
LP: | L A G E D R U K R E G E L A A R |
| ( A U T O M A T I S C H E H E R S T A R T ) |
K1: | CONTACTSCHAKELAAR COMPRES. 1 |
K2: | CONTACTSCHAKELAAR COMPRES. 2 |
K3: | CONTACTSCHAKELAAR POMP |
M1, M2: | COMPRESSOREN 1 EN 2 |
M3, M4: | VENTILATOREN | |
M5: | POMP | |
PDW: | V E R S C H I L D R U K R E G E L A A R |
| WATERCIRCUIT | |
Q:AUTOMATISCHE SCHAKELAARS
RE: | V E R W A R M I N G S E L E M E N T |
| VERDAMPER |
RD: | V E R W A R M I N G S E L E M E N T V A T |
R7: | CARTERVERWARMING COMPRES. 1 |
R8: | CARTERVERWARMING COMPRES. 2 |
RCH: | KOELING/VERWARMING OP AFSTAND |
ROO: | AAN/UIT OP AFSTAND |
T1: | TRANSFORMATOR 230/24V |
TK1, TK2: THERMISCHE BEVEILIGINGEN |
| VENTILATOREN M3 EN M4 |
TL: | LOCALE BEDIENINGSTERMINAL |
V4V: | 4-WEGKLEP (ALLEEN BIJ YCSA-H) |
01 | 02 | 03 | 04 | 05 | | 6 | | | | 7 | 8 | 9 |
| 400V,3 ~,50Hz,N, | | | | Q5 | | B | | | | |
| L1L2 L3 N | | | YCSA/YCSA-H 50 | | 63 | 3 x 25,16 ( | ) 2,5(N) | | |
| | | | YCSA/YCSA-H 60 | | 80 | | |
| | | | | | | | | | |
| Q4 | | | | | | | | | | | |
| 30 m A | IO | | | | | | | | | | |
| | | | | | | | | | | a |
| Q5 | | | | | | | | | | |
| | | | | | | | | | | |
| | | | | | | | | | | 21 | 21 |
| L1 L2 L3 N | | | | T2 M1 | | | | T2 M1 | K1 | K2 |
| | | | L | S1 | | | S1 | 22 | 22 |
| "B" mm2 Cu | | | S2 | (13) | | S2 | (26) | | |
| | | A3 | | | A4 | | |
| L1 L2 L3 | N | | | | T1 M2 | | | | T1 M2 | R7 | R8 |
| | | | | | | | |
| | Q6 | | | | | | | | |
| Q7 | | | | | | | | | | |
| | | | N | | | | | | | | b |
(16)
| 1 | 3 | 5 | 13 | | 1 | 3 | 5 | | 1 | 3 | 5 | | | |
Q3 | 2 | 4 | 6 | 14 | Q1 | 2 | 4 | 6 | Q2 | 2 | 4 | 6 | L | N Y | GND |
| | |
| | | | | | | | | | | | | LOAD | F2 |
| | | | | | | | | | | | | | FSC |
| | | | | | | | | | | | | | |
K3 | 1 | 3 | 5 | 13 | K1 | 1 | 3 | 5 | K2 | 1 | 3 | 5 | | | |
2 | 4 | 6 | 14 | 2 | 4 | 6 | 2 | 4 | 6 | | | |
| | | F | S | |
| | | | (16) | | | | | | | | | |
| | | | | | | | | | | | | | |
| | | | | | | | | | | | | | C1 | C2 |
| | M5 | | | | | M1 | | | | | | | M3 | M4 |
| | | | | | | | | M2 | | | | c |
| | | | | | | | | | | | | | | d |
| DE COMPONENTEN IN DEZE SCHEMA’S WORDEN NIET DOOR | I-2409a (1/2) |
| DE FABRIKANT GELEVERD |
| YCSA/YCSA-H 50 en 60 |
| |
| DE COMPONENTEN IN DEZE SCHEMA’S ZIJN STANDAARD | 400.3.50 |
| TOEBEHOREN | |
YCSA/YCSA-H 50 en 60 T en TP, 400.3.50
Elektrische installatie
Arrefecedoras de água e bombas de calor ar-água
Enfriadoras de agua y bombas de calor aire-agua
GB Air-water chillers and heat pumps
Refrigeratori dacqua e pompe di calore aria-acqua
Page
Page
1000
YCSA/YCSA-H 50 y 60 T y TP
Notas
Instrucciones de instala- ción
Instalación eléctrica
Kit Hydro, soló unidades versión P
Antes de dar por finalizada la instalación
Límites de utilización
Unidades sin pack
Datos físicos unidades soló frio
Datos físicos unidades bomba de calor
Instalación eléctrica
Diagrama eléctrico
Datos y medidas susceptibles de variación sin previo aviso
Installation Instructions
Wiring
Hydro Kit, version P units only
Prior to final approval of the installation
Limits of use
Units without pack
Physical data, cool only units
Physical data, heat pump units
YCSA/YCSA-H 50 & 60 T & TP
50 & 60 T
All data subject to change without notice
Instructions d’installation
Installation électrique
Kit Hydro, uniquement unités version P
Derniers contrôles
Limites d’utilisation
Unités sans pack
Données physiques unités froid seul
Données physiques unités réversibles
Installation électrique
YCSA/YCSA-H 50 et 60 T et TP
LES Composants Inclus Dans CES Cadres NE Sont PAS
YCSA/YCSA-H 50 et 60 T et TP
TK2
Instruções de instalação
Instalação eléctrica
Kit Hydro, só nas unidades da versão P
Antes de dar por finalizada a instalação
Limites de utilização
Unidades sem pack
Dados físicos das unidades de só frio
Dados físicos das unidades de bomba de calor
Instalação eléctrica
YCSA/YCSA-H 50 e 60 T e TP
400
Dados e medidas susceptíveis de variação sem aviso prévio
Impianto elettrico
Limiti d’impiego
Prima di considerare ultimata l’installazione
Verificare
Dati tecnici delle unità solo freddo
Schema elettrico
Componenti Inclusi in Questi Riquadri NON Vengono
Dati e misure soggetti a variazioni senza preavviso
Hinweise zum Einbau
Elektrik
Hydro-Bausatz, nur Einheiten Version P
Vor Abschluss des Einbaus
Einsatzgrenzen
Einheiten ohne Pack
Physikalische Angaben, Einheiten Nur Kühlen
Physikalische Angaben, Einheiten Wärmepumpe
Schaltbild
YCSA/YCSA-H 50 und 60 T und TP
Kondensatoren Ventilatormotoren
YCSA/YCSA-H 50 und 60 T und TP
Und TP 400.3.50
Installatie-instructies
Elektrische installatie
Waterset, enkel units P-versie
Alvorens het installeren als beëindigd te beschouwen
Gebruikslimieten
Units zonder pack
Fysieke gegevens units enkel koeling
Fysieke gegevens warmtepompen
Elektrische installatie
YCSA/YCSA-H 50 en 60 T en TP
DE Componenten in Deze SCHEMA’S Worden Niet Door
YCSA/YCSA-H 50 en 60 T en TP
Installasjonsinstrukser
Kit Hydro, kun enheter versjon P
Før man anser installasjonen for avsluttet
Bruksgrenser
Enheter uten pack
Fysikalske data enheter varmepumpe
Fysikalske data enheter kun avkjøling
Elektrisk installasjon
YCSA/YCSA-H 50 og 60 T og TP
Elektrisk skjema
YCSA/YCSA-H 50 og 60 T og TP
Bare I YCSA-H
Page
Declaracion CE DE Conformidad Sobre Maquinas
Directivas DE LA CE Aplicadas