York DR150, DR120, DR090 manual Table Of Contents, List Of Figures, List Of Tables, YTG-C-0606

Page 2

246721-YTG-C-0606

TABLE OF CONTENTS

DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 FACTORY INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . . . 6

FIELD INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . . . 8 REHEAT MODE SEQUENCE OF OPERATION . . . . . . . . . . 9

NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . 62

LIST OF FIGURES

Fig. #

Pg. #

1 PREDATOR® MAGNADRY™ DR090, 120 . . . . . . . . . . . . 4 2 PREDATOR® MAGNADRY™ DR150 . . . . . . . . . . . . . . . . 5 3 REHEAT CONTROL BOARD . . . . . . . . . . . . . . . . . . . . . . 10 4 DR090 & 120 REHEAT CONTROLS . . . . . . . . . . . . . . . . 11 5 DR150 REHEAT CONTROLS. . . . . . . . . . . . . . . . . . . . . . 12 6 DR090 MOISTURE REMOVAL - ALTERNATE MODE . . 23 7 DR090 MOISTURE REMOVAL - NORMAL MODE . . . . . 23 8 DR120 MOISTURE REMOVAL - ALTERNATE MODE . . 24 9 DR120 MOISTURE REMOVAL - NORMAL MODE . . . . . 24

10 DR150 MOISTURE REMOVAL - ALTERNATE MODE . . 25 11 DR150 MOISTURE REMOVAL - NORMAL MODE . . . . . 25 12 DR090, 120 UNITS 4 POINT LOAD . . . . . . . . . . . . . . . . . 42 13 DR090, 120 UNITS 6 POINT LOAD . . . . . . . . . . . . . . . . . 42 14 UNIT CENTER OF GRAVITY DR090, 120 . . . . . . . . . . . . 42 15 DR150 UNIT 4 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . 42 16 DR150 UNIT 6 POINT LOAD . . . . . . . . . . . . . . . . . . . . . . 42 17 UNIT CENTER OF GRAVITY DR150 . . . . . . . . . . . . . . . . 42 18 DR090/120 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . 43 19 DR150 UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . 44 20 PREDATOR® ROOF CURB DIMENSIONS . . . . . . . . . . . 45

21 SUNLINE™ TO PREDATOR® TRANSITION

ROOF CURBS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

22 BOTTOM DUCT OPENINGS (FROM ABOVE) . . . . . . . . 46 23 DR090, 120 REAR DUCT DIMENSIONS . . . . . . . . . . . . . 46 24 DR150 REAR DUCT DIMENSIONS . . . . . . . . . . . . . . . . . 47 25 DOWNFLOW ECONOMIZER HOOD DETAIL . . . . . . . . . 47 26 DOWNFLOW ECONOMIZER HOOD DETAIL . . . . . . . . . 48

27 FACTORY INSTALLED DOWNFLOW ECONOMIZER . . 49

28 FIELD INSTALLED DOWNFLOW ECONOMIZER W/POWER EXHAUST. . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

29 FIELD INSTALLED HORIZONTAL ECONOMIZER W/POWER EXHAUST. . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

30 SLAB ECONOMIZER DOWNFLOW W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50

31 SLAB ECONOMIZER END RETURN W/POWER EXHAUST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

32 TYPICAL LOW VOLTAGE FIELD WIRING . . . . . . . . . . . 52

33 FIELD WIRING DISCONNECT-COOLING UNIT WITH/ WITHOUT ELECTRIC HEAT . . . . . . . . . . . . . . . . . . . . . . 53

34 FIELD WIRING DISCONNECT-COOLING UNIT

WITH GAS HEAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53

35 DR090, 120 COOLING UNIT WITH GAS HEAT

WIRING 230 VOLT DIAGRAM . . . . . . . . . . . . . . . . . . . . . 54

36 DR150 COOLING UNIT WITH GAS HEAT

WIRING 230 VOLT DIAGRAM . . . . . . . . . . . . . . . . . . . . . 55

37 DR090, 120 COOLING UNIT WITH/WITHOUT ELECTRIC HEAT WIRING DIAGRAM . . . . . . . . . . . . . . . 56

38 DR150 COOLING UNIT WITH/WITHOUT ELECTRIC HEAT WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . 57

39 DR090, 120 COOLING UNIT WITH GAS HEAT WIRING 460, 575 VOLT 50 HZ DIAGRAM . . . . . . . . . . . . . . . . . . . 58

40 DR150 COOLING UNIT WITH GAS HEAT WIRING

460, 575 & 50 HZ DIAGRAM . . . . . . . . . . . . . . . . . . . . . . 59

41 DR090 AND 120 REHEAT WIRING DIAGRAM . . . . . . . . 60 42 DR150 REHEAT WIRING DIAGRAM. . . . . . . . . . . . . . . . 61

LIST OF TABLES

Tbl. #

Pg. #

1 ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

2 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

3 DR CAPACITY RATINGS. . . . . . . . . . . . . . . . . . . . . . . . . 16

4 UNIT VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . 16

5 COOLING CAPACITY DR090 UNIT . . . . . . . . . . . . . . . . 17

6 COOLING CAPACITY DR090 UNIT

(ALTERNATE REHEAT MODE) . . . . . . . . . . . . . . . . . . . . 18

7 COOLING CAPACITY DR120 UNIT . . . . . . . . . . . . . . . . 19

8 COOLING CAPACITY DR120 UNIT

(ALTERNATE REHEAT MODE) . . . . . . . . . . . . . . . . . . . . 20

9 COOLING CAPACITY DR150 UNIT . . . . . . . . . . . . . . . . 21

10 COOLING CAPACITY DR150 UNIT

(ALTERNATE REHEAT MODE) . . . . . . . . . . . . . . . . . . . . 22

11 ELECTRICAL DATA DR090 W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . 26

12 ELECTRICAL DATA DR090 WITH PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . 26

13 ELECTRICAL DATA DR120 W/O PWRD CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . . . . . 27

2

Unitary Products Group

Image 2
Contents TECHNICAL MagnaDRYDESCRIPTION GUIDELIST OF TABLES TABLE OF CONTENTSLIST OF FIGURES 246721-YTG-C-0606246721-YTG-C-0606 16 ELECTRICAL DATA DR150 W/PWRDFIGURE 1 - PREDATOR MagnaDRY DR090 246721-YTG-C-0606246721-YTG-C-0606 FEATURESFIGURE 2 - PREDATOR MagnaDRY DR150 FACTORY INSTALLED OPTIONS 246721-YTG-C-0606246721-YTG-C-0606 Unitary Products GroupFIELD INSTALLED ACCESSORIES 246721-YTG-C-0606REHEAT MODE SEQUENCE OF OPERATION 246721-YTG-C-0606246721-YTG-C-0606 FIGURE 3 - REHEAT CONTROL BOARDALTERNATE” MODE Unitary Products Group FIGURE 4 - DR090 & 120 REHEAT CONTROLS246721-YTG-C-0606 FIGURE 5 - DR150 REHEAT CONTROLS 246721-YTG-C-0606TABLE 1 ACCESSORIES 246721-YTG-C-0606D R 090 N10 A 2 A AA 3 0 1 2 4 A NOMENCLATURE7.5-12.5Ton York Model Number Nomenclature 246721-YTG-C-0606TABLE 2 PHYSICAL DATA 246721-YTG-C-0606TABLE 4 UNIT VOLTAGE LIMITATIONS POWER RATINGTABLE 3 DR CAPACITY RATINGS 246721-YTG-C-0606Unitary Products Group TABLE 5 COOLING CAPACITY DR090 UNIT246721-YTG-C-0606 246721-YTG-C-0606 Air On Evap. CoilUnitary Products Group TABLE 7 COOLING CAPACITY DR120 UNIT246721-YTG-C-0606 246721-YTG-C-0606 Air On EvapUnitary Products Group TABLE 9 COOLING CAPACITY DR150 UNIT246721-YTG-C-0606 246721-YTG-C-0606 10.7indoor dry bulb / wet bulb conditions FIGURE 9 - DR120 MOISTURE REMOVAL - NORMAL MODE 246721-YTG-C-0606DR150 Moisture Removal @ 5000cfm Compressors Unitary Products Group TABLE 17 ELECTRIC HEAT MULTIPLIERS 246721-YTG-C-0606 DR 090 Standard Drive Assembly Side FlowTABLE 18 BLOWER PERFORMANCE DR090 SIDEFLOW 100% Return Economizer DR 090 Optional Drive Assembly Side Flow246721-YTG-C-0606 TABLE 20 BLOWER PERFORMANCE DR090 DOWNFLOW DR 090 Standard Drive Assembly Down FlowDR 090 Optional Drive Assembly Down Flow 246721-YTG-C-0606DR 090 Standard Drive Assembly Down Flow 246721-YTG-C-0606Unitary Products Group TABLE 22 BLOWER PERFORMANCE DR120 SIDEFLOW246721-YTG-C-0606 Volumetric DR120 Standard Drive Assembly Side FlowVolumetric 246721-YTG-C-0606Unitary Products Group TABLE 24 BLOWER PERFORMANCE DR120 DOWNFLOW246721-YTG-C-0606 246721-YTG-C-0606 DR 120 Standard Drive Assembly Down FlowDR 120 Optional Drive Assembly Down Flow 100% Return EconomizerTABLE 26 BLOWER PERFORMANCE DR150 SIDEFLOW DR150 Standard Drive Assembly Side FlowDR150 Optional Drive Assembly Side Flow 246721-YTG-C-0606100% Return Economizer DR150 Optional Drive Assembly Side Flow246721-YTG-C-0606 Unitary Products Group TABLE 28 BLOWER PERFORMANCE DR150 DOWNFLOW246721-YTG-C-0606 246721-YTG-C-0606 100% Return EconomizerTABLE 30 ADDITIONAL STATIC RESISTANCE TABLE 32 INDOOR BLOWER SPECIFICATIONSTABLE 33 POWER EXHAUST SPECIFICATIONS TABLE 31 ELECTRIC HEAT MINIMUM SUPPLY AIR CFMFIGURE 12 - DR090, 120 UNITS 4 POINT LOAD 246721-YTG-C-0606 TABLE 36 UNIT WEIGHTFIGURE 18 - DR090/120 UNIT DIMENSIONS See Detail ADETAIL B FIGURE 19 - DR150 UNIT DIMENSIONSDETAIL A TABLE 37 UNIT CLEARANCES246721-YTG-C-0606 RIGHTFRONT 8or14 2TYP18-1/4 18-1/45-5/3231-11/162-31/32 246721-YTG-C-0606246721-YTG-C-0606 FIGURE 24 - DR150 REAR DUCT DIMENSIONSFIGURE 25 - DOWNFLOW ECONOMIZER HOOD DETAIL Dot Plugs 18-1/4 Return Air28-1/4 Supply Air246721-YTG-C-0606 FIGURE 26 - DOWNFLOW ECONOMIZER HOOD DETAILTABLE 38 ECONOMIZER USAGE Unitary Products Group FIGURE 27 - FACTORY INSTALLED DOWNFLOW ECONOMIZER246721-YTG-C-0606 2EE04705524 Return Air Damper Field Installed 246721-YTG-C-0606 1EH0409 Fresh Air Hood Field Installed Duct WorkPower Exhaust 2EE04705X24 Slab Economizer 1EH0409TYPICAL THERMOSTAT RC RH Y1 Y2 G W1 W2 C FIGURE 32 - TYPICAL LOW VOLTAGE FIELD WIRING246721-YTG-C-0606 R Y1 Y2 RCB GREHEAT CONTROL W1 BOARD W2 OCC CUnitary Products Group SUPPLIED DISCONNECT GROUND LUG THREE PHASE POWERTHREE PHASE POWER SUPPLY TERMINAL BLOCK TB1 FACTORY OR FIELD246721-YTG-C-0606 246721-YTG-C-0606 Unitary Products Group246721-YTG-C-0606 246721-YTG-C-0606 Unitary Products Group246721-YTG-C-0606 246721-YTG-C-0606 Unitary Products GroupFIGURE 41 - DR090 AND 120 REHEAT WIRING DIAGRAM 246721-YTG-C-0606Unitary Products Group FIGURE 42 - DR150 REHEAT WIRING DIAGRAM246721-YTG-C-0606 GENERAL GUIDE SPECIFICATIONSPREDATOR MagnaDRY DR DESCRIPTIONGAS HEATING SECTION IF EQUIPPED UNIT OPERATING CHARACTERISTICS246721-YTG-C-0606 ELECTRIC HEATING SECTION IF EQUIPPEDADDITIONAL FACTORY INSTALLED OPTIONS