York DR120, DR090 manual Features, PREDATOR MagnaDRY DR150, YTG-C-0606

Page 5
FIGURE 2 - PREDATOR® MagnaDRY™ DR150

246721-YTG-C-0606

 

Simplicity™ Control

Disconnect

Filter access

 

board w/screw

Second model

location (optional

(2" throw-away)

connectors for T-stat

disconnect switch)

 

nameplate inside

Filter drier (solid core)

 

wiring and Network

 

hinged access panel

 

 

Connection

 

 

 

 

 

 

 

 

Condenser Section

Dual stage cooling

 

 

Belt-drive blower

for maximum

 

 

 

 

motor

comfort

 

 

 

 

 

 

 

 

Slide out motor

Compressor #2

 

 

and blower

 

 

assembly for easy

access

 

 

 

 

adjustment and

(high-efficiency

 

 

 

 

service

compressor w/

 

 

 

 

 

crankcase heater)

 

 

Power ventor

 

 

 

 

 

 

motor

Base rails w/ forklift slots

(three sides)

and lifting FEATURES holes

Roof curbs in eight-and fourteen-inch heights.

Roof curbs for

transitioning from York Sunline TM footprint to the DM/DH/DJ Series footprint are available (field-installed accessory)

Tool-less door

latch

Side entry power and control wiring knockouts

Slide-out drain pan with brass ¾" NPT, female connection

Compressor #1 access

(high-efficiency

compressor w/crankcase

heater)

20-gauge

aluminized steel

tubular heat

exchanger for

long life

(stainless steel

option)

Two-stage gas heating to

maintain warm,

comfortable temperature

Intelligent control board for safe and efficient operation

FIGURE 2 - PREDATOR® MagnaDRY™ DR150

FEATURES

High Efficiency – High efficiency units reach as high as 11.2 EER. Gas/electric units have electronic spark igni- tion and power vented combustion with steady state effi- ciencies of 80%. These efficiencies exceed all legislated minimum levels and provide low operating costs.

Service Friendly – The Predator® incorporates a num- ber of enhancements which improve serviceability.

The motor and blower slide out of the unit as a common assembly. This facilitates greater access to all the indoor airflow components, thus simplifying maintenance and adjustment.

Service time is reduced through the use of hinged, tool- less panels. Such panels provide access to frequently inspected components and areas, including the control box, compressors, filters, indoor motor & blower, and the heating section. The panels are screwed in place at the factory to prevent access by children or other unautho- rized persons. It is recommended that the panels be secured with screws once service is complete.

Service windows have been placed in both condenser section walls. Rotation of the cover allows easy access to the condenser coils for cleaning or inspection.

Both the unit control board and ignition control board utilize flash codes to aid in diagnosis of unit malfunctions. Unique alarm codes quickly identify the source of the unit alarm.

All units use the same standard filter size. This standard- ization removes any confusion on which filter sizes are needed for replacement.

The non-corrosive drain pan slides out of the unit to per- mit easy cleaning. The drain pan is accessed by remov- ing the drain pan cover plate on the rear of the unit. Once the plate is removed, the drain pan slides out through the rear of the unit.

All Predator® units have a second model nameplate located inside the control access door. This is to prevent deterioration of the nameplate through weathering.

Environmentally Aware – For improved Indoor Air Quality, foil faced insulation is used exclusively throughout the units.

Balanced Heating – The Predator® offers “Ultimate Heat- ing Comfort” with a balance between 1st and 2nd stage gas heating. The first stage of a gas heat Predator® unit provides 60% of the heating capacity. Balanced heating allows the unit to better maintain desired temperatures.

Convertible Airflow Design – The side duct openings are covered when they leave the factory. If a side supply/

Unitary Products Group

5

Image 5
Contents DESCRIPTION MagnaDRYTECHNICAL GUIDELIST OF FIGURES TABLE OF CONTENTSLIST OF TABLES 246721-YTG-C-060616 ELECTRICAL DATA DR150 W/PWRD 246721-YTG-C-0606246721-YTG-C-0606 FIGURE 1 - PREDATOR MagnaDRY DR090246721-YTG-C-0606 FEATURESFIGURE 2 - PREDATOR MagnaDRY DR150 246721-YTG-C-0606 FACTORY INSTALLED OPTIONSUnitary Products Group 246721-YTG-C-0606246721-YTG-C-0606 FIELD INSTALLED ACCESSORIES246721-YTG-C-0606 REHEAT MODE SEQUENCE OF OPERATION246721-YTG-C-0606 FIGURE 3 - REHEAT CONTROL BOARDALTERNATE” MODE Unitary Products Group FIGURE 4 - DR090 & 120 REHEAT CONTROLS246721-YTG-C-0606 246721-YTG-C-0606 FIGURE 5 - DR150 REHEAT CONTROLS246721-YTG-C-0606 TABLE 1 ACCESSORIES7.5-12.5Ton York Model Number Nomenclature NOMENCLATURED R 090 N10 A 2 A AA 3 0 1 2 4 A 246721-YTG-C-0606246721-YTG-C-0606 TABLE 2 PHYSICAL DATATABLE 3 DR CAPACITY RATINGS POWER RATINGTABLE 4 UNIT VOLTAGE LIMITATIONS 246721-YTG-C-0606Unitary Products Group TABLE 5 COOLING CAPACITY DR090 UNIT246721-YTG-C-0606 Air On Evap. Coil 246721-YTG-C-0606Unitary Products Group TABLE 7 COOLING CAPACITY DR120 UNIT246721-YTG-C-0606 Air On Evap 246721-YTG-C-0606Unitary Products Group TABLE 9 COOLING CAPACITY DR150 UNIT246721-YTG-C-0606 10.7 246721-YTG-C-0606indoor dry bulb / wet bulb conditions 246721-YTG-C-0606 FIGURE 9 - DR120 MOISTURE REMOVAL - NORMAL MODEDR150 Moisture Removal @ 5000cfm Compressors Unitary Products Group TABLE 17 ELECTRIC HEAT MULTIPLIERS 246721-YTG-C-0606 DR 090 Standard Drive Assembly Side FlowTABLE 18 BLOWER PERFORMANCE DR090 SIDEFLOW 100% Return Economizer DR 090 Optional Drive Assembly Side Flow246721-YTG-C-0606 DR 090 Optional Drive Assembly Down Flow DR 090 Standard Drive Assembly Down FlowTABLE 20 BLOWER PERFORMANCE DR090 DOWNFLOW 246721-YTG-C-0606246721-YTG-C-0606 DR 090 Standard Drive Assembly Down FlowUnitary Products Group TABLE 22 BLOWER PERFORMANCE DR120 SIDEFLOW246721-YTG-C-0606 Volumetric DR120 Standard Drive Assembly Side FlowVolumetric 246721-YTG-C-0606Unitary Products Group TABLE 24 BLOWER PERFORMANCE DR120 DOWNFLOW246721-YTG-C-0606 DR 120 Optional Drive Assembly Down Flow DR 120 Standard Drive Assembly Down Flow246721-YTG-C-0606 100% Return EconomizerDR150 Optional Drive Assembly Side Flow DR150 Standard Drive Assembly Side FlowTABLE 26 BLOWER PERFORMANCE DR150 SIDEFLOW 246721-YTG-C-0606100% Return Economizer DR150 Optional Drive Assembly Side Flow246721-YTG-C-0606 Unitary Products Group TABLE 28 BLOWER PERFORMANCE DR150 DOWNFLOW246721-YTG-C-0606 100% Return Economizer 246721-YTG-C-0606TABLE 33 POWER EXHAUST SPECIFICATIONS TABLE 32 INDOOR BLOWER SPECIFICATIONSTABLE 30 ADDITIONAL STATIC RESISTANCE TABLE 31 ELECTRIC HEAT MINIMUM SUPPLY AIR CFMFIGURE 12 - DR090, 120 UNITS 4 POINT LOAD FIGURE 18 - DR090/120 UNIT DIMENSIONS TABLE 36 UNIT WEIGHT246721-YTG-C-0606 See Detail ADETAIL A FIGURE 19 - DR150 UNIT DIMENSIONSDETAIL B TABLE 37 UNIT CLEARANCESFRONT 8or14 RIGHT246721-YTG-C-0606 2TYP31-11/162-31/32 18-1/45-5/3218-1/4 246721-YTG-C-0606FIGURE 25 - DOWNFLOW ECONOMIZER HOOD DETAIL FIGURE 24 - DR150 REAR DUCT DIMENSIONS246721-YTG-C-0606 Dot Plugs 18-1/4 Return Air28-1/4 Supply Air246721-YTG-C-0606 FIGURE 26 - DOWNFLOW ECONOMIZER HOOD DETAILTABLE 38 ECONOMIZER USAGE Unitary Products Group FIGURE 27 - FACTORY INSTALLED DOWNFLOW ECONOMIZER246721-YTG-C-0606 2EE04705524 Return Air Damper Field Installed Power Exhaust 1EH0409 Fresh Air Hood Field Installed Duct Work246721-YTG-C-0606 2EE04705X24 Slab Economizer 1EH0409246721-YTG-C-0606 FIGURE 32 - TYPICAL LOW VOLTAGE FIELD WIRINGTYPICAL THERMOSTAT RC RH Y1 Y2 G W1 W2 C R Y1 Y2 RCB GREHEAT CONTROL W1 BOARD W2 OCC CTHREE PHASE POWER SUPPLY SUPPLIED DISCONNECT GROUND LUG THREE PHASE POWERUnitary Products Group TERMINAL BLOCK TB1 FACTORY OR FIELD246721-YTG-C-0606 Unitary Products Group 246721-YTG-C-0606246721-YTG-C-0606 Unitary Products Group 246721-YTG-C-0606246721-YTG-C-0606 Unitary Products Group 246721-YTG-C-0606246721-YTG-C-0606 FIGURE 41 - DR090 AND 120 REHEAT WIRING DIAGRAMUnitary Products Group FIGURE 42 - DR150 REHEAT WIRING DIAGRAM246721-YTG-C-0606 PREDATOR MagnaDRY DR GUIDE SPECIFICATIONSGENERAL DESCRIPTION246721-YTG-C-0606 UNIT OPERATING CHARACTERISTICSGAS HEATING SECTION IF EQUIPPED ELECTRIC HEATING SECTION IF EQUIPPEDADDITIONAL FACTORY INSTALLED OPTIONS