York BP 090 Additional Static Resistance Imperial, Additional Static Resistance Metric, Cfm, M3S

Page 32

66307-YIM-B-0606

TABLE 30: ADDITIONAL STATIC RESISTANCE - IMPERIAL

CFM

Cooling Only*

Economizer† ‡

 

Electric Heat KW

 

9

18

24

36

54

 

 

 

 

 

 

 

 

 

 

 

2300

0.08

0.02

0.07

0.08

0.09

0.10

0.13

2500

0.09

0.02

0.08

0.09

0.10

0.11

0.14

2700

0.11

0.03

0.09

0.10

0.12

0.13

0.16

2900

0.12

0.03

0.10

0.11

0.13

0.14

0.18

3100

0.14

0.03

0.12

0.13

0.15

0.16

0.20

3300

0.16

0.03

0.13

0.14

0.17

0.18

0.22

3500

0.18

0.04

0.15

0.16

0.19

0.20

0.24

3700

0.20

0.04

0.17

0.18

0.21

0.22

0.26

3900

0.23

0.04

0.19

0.20

0.23

0.24

0.28

4100

0.25

0.04

0.21

0.22

0.25

0.26

0.31

4300

0.28

0.05

0.23

0.24

0.28

0.29

0.34

4500

0.30

0.05

0.25

0.26

0.30

0.31

0.37

4700

0.33

0.05

0.28

0.29

0.33

0.34

0.40

4900

0.36

0.05

0.30

0.31

0.35

0.37

0.43

5100

0.39

0.06

0.33

0.34

0.38

0.40

0.46

5300

0.42

0.06

0.35

0.37

0.41

0.43

0.49

*. Add these resistance values to the available static resistance in the respective Blower Performance Tables.

†.Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.

‡.The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

TABLE 31: ADDITIONAL STATIC RESISTANCE - METRIC

M3S

Cooling Only*

Economizer† ‡

 

Electric Heat KW

 

9

18

24

36

54

 

 

 

 

 

 

 

 

 

 

 

1.08

19.9

5.0

17.4

19.9

22.4

24.8

32.3

1.18

22.4

5.0

19.9

22.4

24.8

27.3

34.8

1.27

27.3

7.5

22.4

24.8

29.8

32.3

39.7

1.36

29.8

7.5

24.8

27.3

32.3

34.8

44.7

1.46

34.8

7.5

29.8

32.3

37.3

39.7

49.7

1.55

39.7

7.5

32.3

34.8

42.2

44.7

54.6

1.65

44.7

9.9

37.3

39.7

47.2

49.7

59.6

1.74

49.7

9.9

42.2

44.7

52.2

49.7

64.6

1.83

57.1

9.9

47.2

49.7

56.1

59.6

69.5

1.93

62.1

9.9

52.2

54.6

62.1

64.6

77.0

2.02

69.5

12.4

57.1

59.6

69.5

72.0

88.4

2.12

74.5

12.4

62.1

64.6

74.5

77.0

91.9

2.21

82.0

12.4

69.5

72.0

82.0

84.4

99.3

2.30

89.4

12.4

74.5

77.0

86.9

91.9

106.8

2.40

96.9

14.9

82.0

84.4

94.4

99.3

114.2

2.49

104.3

14.9

86.9

91.9

101.8

106.8

121.7

*. Add these resistance values to the available static resistance in the respective Blower Performance Tables.

†.Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.

‡.The pressure drop through the economizer is greater for 100% outdoor air than for 100% return air. If the resistance of the return air duct system is less than 0.25 IWG, the unit will deliver less CFM during full economizer operation.

32

Unitary Products Group

Image 32
Contents Installation Manual 50 Hz Single Package Heat Pump High EfficiencyTable of Contents List of Figures List of Tables Inspection Safety ConsiderationsGeneral Approvals ReferenceRenewal Parts Ton York Model Number Nomenclature NomenclaturePreceding Installation InstallationInstallation Safety Information Unit Voltage Limitations LocationRigging and Handling Unit WeightsPoint Load Weight Detail B ClearancesUnit Clearances BttomPower Rear Duct Dimensions Ductwork Duct Covers Predator Roof Curb Dimensions Thermostat Wiring Control Wire SizesCompressors FiltersPower Wiring Detail Electronic Thermostat Field WiringGroundlug Electrical Data 7-1/2 TON HP Electrical Data 10 TON HPFactory Installed Options Field Installed Accessories Electric Heat AccessoryPhysical Data Electric Heat OptionElectric Heat Minimum Supply AIR Enthalpy SET Point Chart Indoor AIR Quality AQBelt Tension Blower RotationSupply AIR Limitations Belt Adjustment Blower Performance 7-1/2 TON Standard Motor Side Duct Metric Blower Performance 10 TON Standard Motor Side Duct Imperial Blower Performance 10 TON Standard Motor Side Duct MetricBlower Performance 10 TON Optional Motor Side Duct Imperial Blower Performance 10 TON Optional Motor Side Duct MetricBlower Performance 7-1/2 TON Standard Motor Downshot Metric Blower Performance 10 TON Standard Motor Downshot Metric Blower Performance 7-1/2 TON Optional Motor Downshot MetricBlower Performance 10 TON Standard Motor Downshot Imperial Blower Performance 10 TON Optional Motor Downshot Metric Indoor Blower SpecificationsBlower Performance 10 TON Optional Motor Downshot Imperial AIR Balance Checking AIR QuantityMethod ONE Method TWOSupply AIR Drive Adjustment DRY Coil Delta PAdditional Static Resistance Imperial Additional Static Resistance MetricCFM M3SOperation Motor Sheave DatumSequence of Operations Overview Cooling Sequence of OperationCooling Operation Errors Safety Controls ResetCompressor Protection Heating Sequence of OperationSTART-UP Superheat Charging Method Operating InstructionsPost Start Check List Superheat Charging Cooling Superheat 7-1/2 TONPredator Flash Codes TroubleshootingCooling Superheat 10 TON Unit Control Board Flash Codes Unit Control BoardCooling Troubleshooting Guide Page Page Unitary 5005 Norman Products York Group Drive 73069