York BP120, BP 090 installation manual Ton York Model Number Nomenclature

Page 7

66307-YIM-B-0606

NOMENCLATURE

7.5-10.0 Ton York® Model Number Nomenclature

B P 090 C00 A 7 A AA 3 0 1 2 4 A

Product Category

B = HP, Single Pkg., R-22

Product Identifier

P = 9.3-10.6 EER HP

Nominal Cooling Capacity

090 = 7.5 Ton

120 = 10.0 Ton

Heat Type and Nominal Heat Capacity

C00 = Cooling Only. No heat installed

Electric Heat Options

E09 = 9 KW

E18 = 18 KW

E24 = 24 KW

E36 = 36 KW

E54 = 54 KW

Airflow

A = Std. Motor

B = Std. Motor/Econo./Barometric Relief (Downflow

Only)

C = Std. Motor/Econo./Power Exhaust (Downflow Only)

D = Std. Motor/Motorized Damper (Downflow Only)

E = Std. Motor/Horizontal Economizer (No Baro.)

F = Std. Motor/Slab Econo./Power Exhaust

(Downflow Only)

G = Std. Motor/Slab Econo./Barometric Relief

(Downflow Only)

N = Hi Static Mtr.

P = Hi Static Mtr./Econo./Barometric Relief

(Downflow Only)

Q = Hi Static Mtr./Econo./Power Exhaust

(Downflow Only)

R = Hi Static Mtr./Motorized Damper (Downflow Only)

S = Hi Static Mtr./Horizontal Economizer (No Baro.)

T = Hi Static Mtr./Slab Econo./Power Exhaust

(Downflow Only)

U = Hi Static Mtr./Slab Econo./Barometric Relief

(Downflow only)

Voltage

7 = 380/415-3-50

Product Style

A = Style A

B = Style B

C = Style C

Configuration Options (not required for all units)

These four digits will not be assigned until a quote is requested, or an order placed.

SS Drain Pan

Honeywell Controller, DFS, APS

Simplicity IntelliComfort Controller

Simplicity IntelliComfort Controller w/ModLinc

2" Pleated filters

BAS Ready Unit with Belimo Economizer

Shipping Bag

Any Combination of Additional Options that Don’t Have an Option Code Pre-assigned

 

 

Product Generation

 

 

 

 

 

 

3

= Third Generation

 

 

4

= Fourth Generation

 

 

 

 

 

 

 

 

 

 

 

 

Additional Options

AA = None

RC = Coil Guard, Shipping Bag & American Flag

AB = Phase Monitor

TA = Technicoat Condenser Coil

AC = Coil Guard

TJ = Technicoat Evaporator Coil

AD = Dirty Filter Switch

TS = Technicoat Evaporator & Condenser Coils

AE = Phase Monitor & Coil Guard

 

AF = Phase Monitor & Dirty Filter Switch

 

AG = Coil Guard & Dirty Filter Switch

 

AH = Phase Monitor, Coil Guard & Dirty Filter Switch

 

 

 

ZZ= If desired option combination is not listed above, ZZ will be assigned and configuration options will be located in digits 15-18.

Installation Options

A = No Options Installed

B = Option 1

C = Option 2

D = Options 1 & 2

E = Option 3

F = Option 4

G = Options 1 & 3

H = Options 1 & 4

J = Options 1, 2 & 3

K = Options 1, 2, & 4

L = Options 1,3 & 4

M = Options 1, 2, 3, & 4

N = Options 2 & 3

P = Options 2 & 4

Q = Options 2, 3, & 4

R = Options 3 & 4

S = Option 5

T = Options 1 & 5

U = Options 1, 3, & 5

V = Options 1, 4, & 5

W = Options 1, 3, 4, & 5

X = Options 3 & 5

Y = Options 4 & 5

Z = Options 3, 4 & 5

Options

1 = Disconnect

2= Non-Pwr'd Conv. Outlet

3 = Smoke Detector S.A.

4 = Smoke Detector R.A.

5 = Pwr'd Conv. Outlet

Unitary Products Group

7

Image 7
Contents Single Package Heat Pump High Efficiency Installation Manual 50 HzTable of Contents List of Figures List of Tables General Safety ConsiderationsInspection Renewal Parts ReferenceApprovals Nomenclature Ton York Model Number NomenclatureInstallation Safety Information InstallationPreceding Installation Location Unit Voltage LimitationsPoint Load Weight Unit WeightsRigging and Handling Unit Clearances ClearancesDetail B BttomPower Rear Duct Dimensions Ductwork Duct Covers Predator Roof Curb Dimensions Filters Thermostat WiringControl Wire Sizes CompressorsElectronic Thermostat Field Wiring Power Wiring DetailGroundlug Electrical Data 10 TON HP Electrical Data 7-1/2 TON HPElectric Heat Option Factory Installed Options Field Installed AccessoriesElectric Heat Accessory Physical DataElectric Heat Minimum Supply AIR Indoor AIR Quality AQ Enthalpy SET Point ChartSupply AIR Limitations Blower RotationBelt Tension Belt Adjustment Blower Performance 7-1/2 TON Standard Motor Side Duct Metric Blower Performance 10 TON Standard Motor Side Duct Metric Blower Performance 10 TON Standard Motor Side Duct ImperialBlower Performance 10 TON Optional Motor Side Duct Metric Blower Performance 10 TON Optional Motor Side Duct ImperialBlower Performance 7-1/2 TON Standard Motor Downshot Metric Blower Performance 10 TON Standard Motor Downshot Imperial Blower Performance 7-1/2 TON Optional Motor Downshot MetricBlower Performance 10 TON Standard Motor Downshot Metric Blower Performance 10 TON Optional Motor Downshot Imperial Indoor Blower SpecificationsBlower Performance 10 TON Optional Motor Downshot Metric Method TWO AIR BalanceChecking AIR Quantity Method ONEDRY Coil Delta P Supply AIR Drive AdjustmentM3S Additional Static Resistance ImperialAdditional Static Resistance Metric CFMCooling Sequence of Operation OperationMotor Sheave Datum Sequence of Operations OverviewCooling Operation Errors Heating Sequence of Operation Safety ControlsReset Compressor ProtectionSTART-UP Post Start Check List Operating InstructionsSuperheat Charging Method Cooling Superheat 7-1/2 TON Superheat ChargingCooling Superheat 10 TON TroubleshootingPredator Flash Codes Unit Control Board Unit Control Board Flash CodesCooling Troubleshooting Guide Page Page Unitary 5005 Norman Products York Group Drive 73069