Simran RPU80 instruction manual RPU160 performance, RPU300 performance

Page 34

Simrad Reversible Pump RPU80/160/300

8.4 RPU160 performance

CAPACITY (l/min)

2.0

23

AMPS

1.5

17

 

1.0

11

 

0.5

5

 

0

10

20

30

40

50

60

 

 

PRESSURE (BAR)

 

 

 

Capacity versus

 

 

Current versus

 

pressure

 

 

pressure

 

8.5 RPU300 performance*

 

3.5

 

 

 

 

 

 

30

 

CAPACITY (l/min)

3.0

 

 

 

 

 

 

25

 

2.5

 

 

 

 

 

 

20

AMPS

2.0

 

 

 

 

 

 

15

 

 

V

 

 

 

 

 

 

2

 

 

 

 

 

1.5

1

 

 

 

 

 

10

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.0

24

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

0

 

10

20

30

40

50

60

 

PRESSURE (BAR)

Capacity versus

Current versus

pressure

pressure

* Measured at charging voltage.

32

20220422N

www.Busse-Yachtshop.de email: info@busse-yachtshop.de

Image 34
Contents Simrad RPU80/160/300 Reversible Pump Copyright 20220422N Document revisions Contents Technical Specifications Introduction General20220422N Capilano, Flexatrol Canadian. See Seastar Harmek Norwegian RPU160 RPU300 BCS ItalianBosvik Norwegian HC HYDRO-CONTROL GermanRPU160 RPU300 Hynautic Lecomble & Schmitt FranceRPU160 RPU300 Lecomble & Schmitt Old models Seipem ItalianTeleflex See Seastar Tenfjord Norwegian RPU160 RPU300 Servi NorwegianSLEIPNER, Hydrive Norwegian Vetus DutchRPU160 RPU300 Vetus Wagner CanadianMinimum rudder time adjustment Calculation of cylinder volumeMeasurements and Calculations for Applying the RPU Capacity nomogram for Reversible Pump RPU80/RPU160/RPU300 Description of RPU80/RPU160/RPU300 ConstructionPrinciple of operation ref. -1 and figure Pressure operated non-return check valves on outlet a and B Valve blockGear pump Suction valves on outlet CPipe connections Installation Mechanical InstallationInstallation of pipes Connection to expansion tank Connection to hand hydraulic steering gear Electrical installation J3000X, J300X, J300X-40, J50, J50-40 AC10, AC20, AC40Testing Preparation and TestingOil filling and bleeding Dismantling MaintenanceElectric motor Piston rod does not move with rudder commands Fault TracingPump motor is not running/not responding to rudder command Excessive noise from the pump unitSteering wheel is turning while pump unit is operated Piston rod of the rudder cylinder does not move smoothlySmall and sudden heading changes while on automatic steering Rudder moves only in one direction with pump running Activator reduces the hardening time to 1 hourTechnical Specifications SpecificationsDimensions RPU80 performance RPU160 performance RPU300 performanceRPU80/RPU160/RPU300 Spare PartsPos Qty Gear pump parts Motor parts Lemac Parts for Fracmo motorsRPU80 Previous model gear pump Pos Qty Gear pump parts Previous RPU80 modelSales and Service Worldwide Europe