Harmony Function Chart
| Depress the knob to move | |
| forward through the menus and to | |
| accept changes, rotate the knob | |
The digital display shows the system status, | to change a setting's value | |
Depress the button to go back | ||
set point, lead stage <in brackets>, and | ||
status of each stage. To view and adjust | through the menus, or to view a | |
settings, press the Adjust/Select button | setting value without changing it |
| FULL MODULATION |
|
|
|
|
| |||
| SEQUENCING CONTROL |
|
|
|
|
| |||
| HARMONY |
| TO SENSOR TERMINALS |
| |||||
|
|
|
|
|
| DO NOT APPLY ANY VOLTAGE |
| ||
|
|
|
|
|
|
| INPUTS |
| |
MENU FUNCTIONS |
|
|
|
| ADJUST |
| A1 | T SYSTEM | To Temp sensor mounted |
|
|
|
|
|
| A2 | TEMP | in common header | |
SELECT enters menus or accepts changes |
|
| 181 |
|
|
| A3 |
| When closed, all stages |
|
|
|
|
|
|
| SHUTDOWN | ||
ADJUST selects menu items or changes settings |
|
|
|
| PRESS TO | A4 | are turned off* | ||
|
|
|
|
|
|
|
| ||
BACK returns to previous menu | <A> | B | C | D | SELECT |
| A5 | + |
|
STAGE selects stage menus or next stage | 100 | 52 | OFF | STBY |
|
| A6 | S |
|
| BACK |
|
| ||||||
PREV/NEXT steps through stage settings |
|
|
|
|
| A7 | NETWORK | To network sensors** | |
|
|
|
|
|
|
| A8 | ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| A9 | SYSTEM Checks status of system | |
|
|
|
|
|
|
| A10 | PROVE | components* |
|
|
|
|
|
|
|
|
| |
| HELP | PREV. | STAGE | NEXT |
|
| A11 | T OUTDOOR | Optional sensor enables |
|
|
|
|
|
|
| A12 | TEMP | outdoor reset |
|
|
|
|
|
|
|
|
| |
|
|
|
|
| BURNER | B1 | STAGE |
| |
|
|
|
|
|
| ACTIVE |
|
| |
|
|
|
|
|
| B2 | A |
| |
|
|
|
|
|
|
|
|
|
|
| SYSTEM |
|
| A |
|
| B | C |
| D |
|
|
|
|
|
| B3 | STAGE | If input is not made, | ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| EMS INPUT | B4 | B | the Harmony will not | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B5 | STAGE | consider it an active | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| B6 | C | stage* | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| + SIGNAL |
| B7 | STAGE |
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| SHIELD | B8 | D |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| C1 | C2 | C3 | C4 | C5 | C6 | C7 | C8 | C9 | C10 | C11 | C12 |
|
|
|
|
|
|
|
| C |
|
|
| Provides remote set |
|
|
|
|
|
|
|
|
|
|
| point adjustment with |
SAFETY |
|
|
|
|
|
| A | B | C | D | a |
LINE | NEUTRAL |
|
|
|
|
| |||||
GROUND | SYS | A | B | C | D | MODULATION OUTPUTS |
|
| |||
MUST BE |
|
|
|
| OPERATING LIMIT |
|
|
| |||
CONNECTED |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| OUTPUTS |
|
|
|
|
| |
MADE IN U.S.A. |
|
|
|
|
|
|
|
|
|
| |
Green Ground |
| System Output |
| One output relay is required for |
|
|
| ||||
screw must be |
| controls pumps, |
|
|
| ||||||
|
| each stage. |
|
|
|
| |||||
connected to |
| valves or other system |
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||
Earth Ground |
| components |
|
|
|
|
|
|
|
120VAC | Each N.O. output is |
Power | wired in series with |
| each unit's limit circuit |
*DRY CONTACTS ONLY
**Only available with the Remote Communications package
The modulation outputs can be
2