120/230 VOLTAGE SELECTOR SWITCH

4 Route the wires and cables through the center of the Esprit mount. Re- install the transformer module into the base. The transformer module can be positioned in the mount base in only one orientation.

5

6

ES3012-5 Model Only – Set the 120/230 voltage selector switch on the trans- former to the appropriate voltage.

Connect wires and cables.

a.Connect to power. Use the two supplied clamp connectors to connect the AC line and neutral.

120/230 VAC

 

24 VAC

Black wire

Input (AC Line)

 

White wire

Input (AC Line)

White wire

AC Neutral

 

White wire

AC Neutral

Green wire

Ground

 

Green wire

Ground

 

 

 

 

 

b.Connect the video coaxial cable to the BNC connector.

c.Connect the wiring for a two-wire or four-wire control system. This step does not apply to Coaxitron® control systems.

Green wire

RX-

Red wire

RX+

Black wire

TX-

White wire

TX+

 

 

7 Install mount; refer to the installation manual supplied with the mount for instructions.

10

Pelco Manual C306M-K (4/05)

Image 10
Contents ES3012 Series Esprit Pelco Manual C306M-K 4/05 Contents List of Illustrations Esprit ES3012 System Dimensions DrawingList of Tables Important Safety Instructions Models DescriptionBasic Installation Camera and Lens InstallationPIN Holder PAN and Tilt Installation RX+ Pelco Manual C306M-K 4/05 TXB Series Translator Board Installation Optional HOW to Remove the PAN and Tilt CoverHOW to Reinstall the PAN and Tilt Cover Operation POWER-UP DisplayHOW to Operate Your Esprit Integrated Positioning System Operating Notes Environmental RangeLens Functions Preset FunctionsPAN, SCAN, and Tilt Speeds RANDOM, FRAME, and Auto ScanningProgramming PresetsEsprit Menus Accessing Main Menu Preset AZ/EL AZ/EL Line Azimuth Zero Direction Direction Line Display Duration Limit Stops Turning Limit Stops on or OFF Programming Limit StopsScan Limit Stops Park Time PAN/SCAN SpeedPattern Length POWER-UP Mode Speed Profile Zone Blank Other MenuSymptom No control/sluggish control Coaxitron TroubleshootingSymptom System does not operate Symptom No control RS-422Maintenance Symptom No video or poor videoAppendix Switch Setting SW1-4 SW1-5Baud Rate Table B. Switch Settings for SW2 112 232 Specifications ElectricalALL Others are Inches Regulatory Notices Product Warranty and Return Information ISO9001