Pelco es3012 installation manual Maintenance, Symptom No video or poor video

Page 31

NOTE: The system con- tains no user-serviceable parts. If there is a problem with your system, it must be returned to Pelco for servicing.

Symptom: No video or poor video

1.Check the video and power connections to the camera.

2.Check for power to the camera from the Esprit system camera power output.

3.Check all coax BNC connectors from the camera to the monitor.

4.Make sure the controller is set for the correct camera-to-monitor viewing combination; for example, Camera 1 to Monitor 1. Refer to the controller manual for information.

5.Check for normal load termination of 75 ohms. When looping through VCRs or multi- plexers, make sure the signal is terminated at the end device. Some termination symp- toms and problems are listed below.

Symptom

Problem

Extremely bright video

No termination or high resistance

Over contrast or contrast

 

level of monitor needs to

 

be increased to maximum

 

for a good video image

Double termination (37.5 ohms)

MAINTENANCE

Clean the enclosure window periodically with a mild non-abrasive detergent in water and a soft cloth to help maintain picture clarity.

If operating problems are experienced with the system, refer to the Troubleshooting section.

The pan and tilt is IP 66 and NEMA 4X certified. The pan and tilt left side cover must be re- moved to gain access to the DIP switches. When the cover is correctly reinstalled, the certi- fication will remain in effect.

Since there are no user-serviceable parts in the Esprit system, if further maintenance is re- quired, it is recommended that the Pelco Customer Service Department be contacted for assistance. Refer to the Warranty and Return Information section.

Pelco Manual C306M-K (4/05)

31

Image 31
Contents ES3012 Series Esprit Pelco Manual C306M-K 4/05 Contents List of Illustrations Esprit ES3012 System Dimensions DrawingList of Tables Important Safety Instructions Models DescriptionBasic Camera and Lens Installation InstallationPIN Holder PAN and Tilt Installation RX+ Pelco Manual C306M-K 4/05 HOW to Remove the PAN and Tilt Cover TXB Series Translator Board Installation OptionalHOW to Reinstall the PAN and Tilt Cover Operating Notes Environmental Range POWER-UP DisplayHOW to Operate Your Esprit Integrated Positioning System OperationRANDOM, FRAME, and Auto Scanning Preset FunctionsPAN, SCAN, and Tilt Speeds Lens FunctionsProgramming PresetsEsprit Menus Accessing Main Menu Preset AZ/EL AZ/EL Line Azimuth Zero Direction Direction Line Display Duration Programming Limit Stops Limit Stops Turning Limit Stops on or OFFScan Limit Stops Park Time PAN/SCAN SpeedPattern Length POWER-UP Mode Speed Profile Other Menu Zone BlankSymptom No control RS-422 TroubleshootingSymptom System does not operate Symptom No control/sluggish control CoaxitronSymptom No video or poor video MaintenanceAppendix Switch Setting SW1-4 SW1-5Baud Rate Table B. Switch Settings for SW2 112 232 Electrical SpecificationsALL Others are Inches Regulatory Notices Product Warranty and Return Information ISO9001