Pelco es3012 installation manual Azimuth Zero

Page 20

AZIMUTH ZERO

MAIN MENU

<Limit Stop>

<Other>

EXIT

Other Menu

Park Time

0

Pan/Scan Spd

7

Power Up

Default

Pat length

6 min

Spd Profile 50 MPH wind

<Zone Blank>

<Az/El/Direction>

Exit

Az/El/Direction

Set Azimuth Zero

Az/El

Az/El Line

Direction

Direction Line

Disp Duration

Exit

Azimuth is the pan angle from 0° to 359°. Azimuth zero is the programmed 0° point that is normally set to magnetic north. Once programmed, on-screen pan position (azimuth) and compass readings are based on the set azimuth zero point.

To set azimuth zero:

1.Program preset 95 (28). The main menu appears.

2.Position the cursor (>) beside Other.

3.Press the Iris Open button to enter the Other menu.

4.Position the cursor (>) beside Az/El/Direction.

5.Press the Iris Open button to enter the Az/El/Direction menu.

6.Position the cursor (>) beside Set Azimuth Zero.

7.Press the Iris Open button. The programming menu for Set Azimuth Zero appears on the monitor.

8.Use the joystick to pan the Esprit unit to the desired azimuth zero (0° point) position.

9.Press the Iris Open button to set the azimuth zero position.

20

Pelco Manual C306M-K (4/05)

Image 20
Contents ES3012 Series Esprit Pelco Manual C306M-K 4/05 Contents List of Tables Esprit ES3012 System Dimensions DrawingList of Illustrations Important Safety Instructions Basic DescriptionModels Installation Camera and Lens InstallationPIN Holder PAN and Tilt Installation RX+ Pelco Manual C306M-K 4/05 TXB Series Translator Board Installation Optional HOW to Remove the PAN and Tilt CoverHOW to Reinstall the PAN and Tilt Cover POWER-UP Display HOW to Operate Your Esprit Integrated Positioning SystemOperation Operating Notes Environmental RangePreset Functions PAN, SCAN, and Tilt SpeedsLens Functions RANDOM, FRAME, and Auto ScanningEsprit Menus PresetsProgramming Accessing Main Menu Preset AZ/EL AZ/EL Line Azimuth Zero Direction Direction Line Display Duration Limit Stops Turning Limit Stops on or OFF Programming Limit StopsScan Limit Stops Pattern Length PAN/SCAN SpeedPark Time POWER-UP Mode Speed Profile Zone Blank Other MenuTroubleshooting Symptom System does not operateSymptom No control/sluggish control Coaxitron Symptom No control RS-422Maintenance Symptom No video or poor videoBaud Rate Switch Setting SW1-4 SW1-5Appendix Table B. Switch Settings for SW2 112 232 Specifications ElectricalALL Others are Inches Regulatory Notices Product Warranty and Return Information ISO9001