POWER-UP DISPLAY
When the Esprit system is powered up or reset, the selected protocol, revision number, and other information is displayed on the monitor. For example, the screen might show the fol- lowing information:
PELCO ESPRIT 1.20 CONFIGURE DONE
D Address 1
P Address 2
The information displayed depends on the selected protocol (C, D, or P) and the menu selection for
The information remains on the monitor until the dome is moved.
HOW TO OPERATE YOUR ESPRIT INTEGRATED POSITIONING SYSTEM
Operation | How to Control |
|
|
Pan and Tilt | Move joystick left/right and up/down. |
|
|
Scanning |
|
Stop Scan | Call preset 96. |
Random Scan | Call preset 97. |
Frame Scan | Call preset 98. |
Auto Scan | Call preset 99. |
|
|
Presets | Refer to the documentation supplied with the controller. |
|
|
Patterns | Refer to the documentation supplied with the controller. |
|
|
Zones | Refer to the Programming section and to the |
| documentation supplied with the controller. |
|
|
For more information refer to Operating Notes.
OPERATING NOTES
ENVIRONMENTAL RANGE
The operating temperature ranges from a minimum of
PAN AND TILT FUNCTIONS
Controller | Pan | Tilt |
Type | (Capability, 360° Continuous | (Viewing Range, +40° to |
| Pan Rotation)** |
|
|
|
|
Fixed speed | Speed determined by | Speed determined by controller |
| controller |
|
|
|
|
*Variable speed | 0.5 to 40° per second, | 0.5 to 20° per second, depending |
| depending on joystick position | on joystick position |
*Turbo Mode | 100° per second | Does not affect the tilt speed |
*Preset Mode | 100° per second | 30° per second |
|
|
|
*50 mph wind speed profile.
**If manual limit stops are set, “Pan Limit” appears on your monitor when a limit stop is reached. This does not apply to scan limit stops.
***When the system reaches the upper limit, “Tilt Limit” appears on your monitor.
14 | Pelco Manual |