Pelco es3012 installation manual Speed Profile

Page 28

SPEED PROFILE

This feature allows the operator to set the wind speed conditions for the location of the system. You can set two wind speed profiles of 50 mph or 90 mph in which the system will remain operational. In both settings, the pan speed will be a maximum of 40 degrees per second. The difference will be in the turbo and preset pan speeds. The turbo and preset pan speeds are 100 degrees per second in the 50 mph wind profile setting and 60 degrees per second in the 90 mph profile.

To set the speed profile:

1.Program preset 95 (28). The main menu appears.

2.Position the cursor (>) beside Other.

3.Press the Iris Open button to enter the entitled Other menu.

4.Position the cursor (>) beside Spd Profile.

5.Press the Iris Open button. The cursor moves to the right, beside the wind speed (50 mph wind or 90 mph wind).

6.Move the joystick up or down to toggle through the wind speeds (50 mph wind or 90 mph wind).

7.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

28

Pelco Manual C306M-K (4/05)

Image 28
Contents ES3012 Series Esprit Pelco Manual C306M-K 4/05 Contents List of Illustrations Esprit ES3012 System Dimensions DrawingList of Tables Important Safety Instructions Models DescriptionBasic Installation Camera and Lens InstallationPIN Holder PAN and Tilt Installation RX+ Pelco Manual C306M-K 4/05 TXB Series Translator Board Installation Optional HOW to Remove the PAN and Tilt CoverHOW to Reinstall the PAN and Tilt Cover POWER-UP Display HOW to Operate Your Esprit Integrated Positioning SystemOperation Operating Notes Environmental RangePreset Functions PAN, SCAN, and Tilt SpeedsLens Functions RANDOM, FRAME, and Auto ScanningProgramming PresetsEsprit Menus Accessing Main Menu Preset AZ/EL AZ/EL Line Azimuth Zero Direction Direction Line Display Duration Limit Stops Turning Limit Stops on or OFF Programming Limit StopsScan Limit Stops Park Time PAN/SCAN SpeedPattern Length POWER-UP Mode Speed Profile Zone Blank Other MenuTroubleshooting Symptom System does not operateSymptom No control/sluggish control Coaxitron Symptom No control RS-422Maintenance Symptom No video or poor videoAppendix Switch Setting SW1-4 SW1-5Baud Rate Table B. Switch Settings for SW2 112 232 Specifications ElectricalALL Others are Inches Regulatory Notices Product Warranty and Return Information ISO9001