Pelco c1487-c operation manual For P-type control systems, refer to Table D

Page 17

Table E. Switch Settings for SW2 – D-Type Control

NOTES: For Coaxitron® controls, all switches on SW2 MUST be OFF.

For P-type control systems, refer to Table D.

Receiver Address

 

 

Switch Setting

 

 

 

 

 

SW2-1

SW2-2

SW2-3 SW2-4 SW2-5

SW2-6 SW2-7 SW2-8

 

 

 

 

 

 

 

 

 

1

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF

2

OFF

ON

OFF

OFF

OFF

OFF

OFF

OFF

3

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

4

OFF

OFF

ON

OFF

OFF

OFF

OFF

OFF

5

ON

OFF

ON

OFF

OFF

OFF

OFF

OFF

6

OFF

ON

ON

OFF

OFF

OFF

OFF

OFF

7

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

8

OFF

OFF

OFF

ON

OFF

OFF

OFF

OFF

9

ON

OFF

OFF

ON

OFF

OFF

OFF

OFF

10

OFF

ON

OFF

ON

OFF

OFF

OFF

OFF

11

ON

ON

OFF

ON

OFF

OFF

OFF

OFF

12

OFF

OFF

ON

ON

OFF

OFF

OFF

OFF

13

ON

OFF

ON

ON

OFF

OFF

OFF

OFF

14

OFF

ON

ON

ON

OFF

OFF

OFF

OFF

15

ON

ON

ON

ON

OFF

OFF

OFF

OFF

16

OFF

OFF

OFF

OFF

ON

OFF

OFF

OFF

17

ON

OFF

OFF

OFF

ON

OFF

OFF

OFF

18

OFF

ON

OFF

OFF

ON

OFF

OFF

OFF

19

ON

ON

OFF

OFF

ON

OFF

OFF

OFF

20

OFF

OFF

ON

OFF

ON

OFF

OFF

OFF

21

ON

OFF

ON

OFF

ON

OFF

OFF

OFF

22

OFF

ON

ON

OFF

ON

OFF

OFF

OFF

23

ON

ON

ON

OFF

ON

OFF

OFF

OFF

24

OFF

OFF

OFF

ON

ON

OFF

OFF

OFF

25

ON

OFF

OFF

ON

ON

OFF

OFF

OFF

26

OFF

ON

OFF

ON

ON

OFF

OFF

OFF

27

ON

ON

OFF

ON

ON

OFF

OFF

OFF

28

OFF

OFF

ON

ON

ON

OFF

OFF

OFF

29

ON

OFF

ON

ON

ON

OFF

OFF

OFF

30

OFF

ON

ON

ON

ON

OFF

OFF

OFF

31

ON

ON

ON

ON

ON

OFF

OFF

OFF

32

OFF

OFF

OFF

OFF

OFF

ON

OFF

OFF

33

ON

OFF

OFF

OFF

OFF

ON

OFF

OFF

34

OFF

ON

OFF

OFF

OFF

ON

OFF

OFF

35

ON

ON

OFF

OFF

OFF

ON

OFF

OFF

36

OFF

OFF

ON

OFF

OFF

ON

OFF

OFF

37

ON

OFF

ON

OFF

OFF

ON

OFF

OFF

38

OFF

ON

ON

OFF

OFF

ON

OFF

OFF

39

ON

ON

ON

OFF

OFF

ON

OFF

OFF

40

OFF

OFF

OFF

ON

OFF

ON

OFF

OFF

41

ON

OFF

OFF

ON

OFF

ON

OFF

OFF

42

OFF

ON

OFF

ON

OFF

ON

OFF

OFF

43

ON

ON

OFF

ON

OFF

ON

OFF

OFF

44

OFF

OFF

ON

ON

OFF

ON

OFF

OFF

45

ON

OFF

ON

ON

OFF

ON

OFF

OFF

46

OFF

ON

ON

ON

OFF

ON

OFF

OFF

47

ON

ON

ON

ON

OFF

ON

OFF

OFF

48

OFF

OFF

OFF

OFF

ON

ON

OFF

OFF

49

ON

OFF

OFF

OFF

ON

ON

OFF

OFF

50

OFF

ON

OFF

OFF

ON

ON

OFF

OFF

51

ON

ON

OFF

OFF

ON

ON

OFF

OFF

52

OFF

OFF

ON

OFF

ON

ON

OFF

OFF

53

ON

OFF

ON

OFF

ON

ON

OFF

OFF

54

OFF

ON

ON

OFF

ON

ON

OFF

OFF

55

ON

ON

ON

OFF

ON

ON

OFF

OFF

56

OFF

OFF

OFF

ON

ON

ON

OFF

OFF

 

 

 

 

 

 

 

 

 

Continued on next page

Pelco Manual C1487M-C (7/99)

17

Image 17
Contents Listed Contents List of Tables List of IllustrationsMeasures DE Securite Importantes Important Safeguards and WarningsGeneral Back Box IN-CEILING ModelsDome Drive Lower DomePendant Components Pendant ModelsModels DescriptionSpectra II Pendant Components Spectra II IN-CEILING ComponentsSpectra Lite Pendant Components Installation for IN-CEILING ModelsSpectra Lite IN-CEILING Components Ceiling and Back BOX PreparationSuspended Ceiling Installing Back BoxWiring Diagram for Spectra WiringRG6/U Cable Type Maximum DistanceTable B VAC Wiring Distances Back BOX InstallationBack BOX Connections From controller To 4-Wire terminal on circuit boardControl Dome Drive Switch Locations Table C. Switch Settings for SW1For D-type control systems, refer to Table E Baud Rate Switch Setting SW2-6 SW2-7 SW2-8For P-type control systems, refer to Table D 100 117 177 Lower Dome Lower Dome Installation, In-Ceiling ModelsPENDANT-MOUNT Installation Installation for Pendant ModelsOperation SURFACE-MOUNT InstallationPAN and Tilt Functions POWER-UP DisplayAuto Flip Scan SpeedSpectra Lite Zoom Preset FunctionsZoom Spectra II Zoom RANDOM, FRAME, and Auto Scanning AlarmsZones PatternsPark Auxiliary OutputsProgramming the Spectra II and Spectra Lite Backlight Compensation Main Menu AccessDenotes items that apply to the Spectra II only Reset CameraZoom Limit GAIN/AGC AGC ModeAuto Iris GainShutter Speed Sharpness AUTO-FOCUS ModeLine Synchronization White Balance Color Cameras onlyPOWER-UP Mode Alarm Resume AUX ModeAlarm Priority Alarm DwellZone Blank Alarm PatternProportional PAN Turning Limit Stops On or Off Limit StopsPattern Length Park Time MinutesSymptom Unit does not operate TroubleshootingSymptom Alarms not going to preset Symptom Fan does not operateSymptom Alarms not starting a pattern Symptom Motion problemsDome Cleaning MaintenanceBack BOX Electronic Assembly Removal Mechanical SpecificationsSD5 Series Dimension Drawing Ntsc EIA Regulatory Notices Warranty and Return Information