Pelco c1487-c operation manual 100

Page 18

Table E. Switch Settings for SW2 – D-Type Control (continued)

Receiver Address

 

 

 

Switch Setting

 

 

 

 

SW2-1

SW2-2

SW2-3

SW2-4 SW2-5

SW2-6

SW2-7

SW2-8

 

 

 

 

 

 

 

 

 

57

ON

OFF

OFF

ON

ON

ON

OFF

OFF

58

OFF

ON

OFF

ON

ON

ON

OFF

OFF

59

ON

ON

OFF

ON

ON

ON

OFF

OFF

60

OFF

OFF

ON

ON

ON

ON

OFF

OFF

61

ON

OFF

ON

ON

ON

ON

OFF

OFF

62

OFF

ON

ON

ON

ON

ON

OFF

OFF

63

ON

ON

ON

ON

ON

ON

OFF

OFF

64

OFF

OFF

OFF

OFF

OFF

OFF

ON

OFF

65

ON

OFF

OFF

OFF

OFF

OFF

ON

OFF

66

OFF

ON

OFF

OFF

OFF

OFF

ON

OFF

67

ON

ON

OFF

OFF

OFF

OFF

ON

OFF

68

OFF

OFF

ON

OFF

OFF

OFF

ON

OFF

69

ON

OFF

ON

OFF

OFF

OFF

ON

OFF

70

OFF

ON

ON

OFF

OFF

OFF

ON

OFF

71

ON

ON

ON

OFF

OFF

OFF

ON

OFF

72

OFF

OFF

OFF

ON

OFF

OFF

ON

OFF

73

ON

OFF

OFF

ON

OFF

OFF

ON

OFF

74

OFF

ON

OFF

ON

OFF

OFF

ON

OFF

75

ON

ON

OFF

ON

OFF

OFF

ON

OFF

76

OFF

OFF

ON

ON

OFF

OFF

ON

OFF

77

ON

OFF

ON

ON

OFF

OFF

ON

OFF

78

OFF

ON

ON

ON

OFF

OFF

ON

OFF

79

ON

ON

ON

ON

OFF

OFF

ON

OFF

80

OFF

OFF

OFF

OFF

ON

OFF

ON

OFF

81

ON

OFF

OFF

OFF

ON

OFF

ON

OFF

82

OFF

ON

OFF

OFF

ON

OFF

ON

OFF

83

ON

ON

OFF

OFF

ON

OFF

ON

OFF

84

OFF

OFF

ON

OFF

ON

OFF

ON

OFF

85

ON

OFF

ON

OFF

ON

OFF

ON

OFF

86

OFF

ON

ON

OFF

ON

OFF

ON

OFF

87

ON

ON

ON

OFF

ON

OFF

ON

OFF

88

OFF

OFF

OFF

ON

ON

OFF

ON

OFF

89

ON

OFF

OFF

ON

ON

OFF

ON

OFF

90

OFF

ON

OFF

ON

ON

OFF

ON

OFF

91

ON

ON

OFF

ON

ON

OFF

ON

OFF

92

OFF

OFF

ON

ON

ON

OFF

ON

OFF

93

ON

OFF

ON

ON

ON

OFF

ON

OFF

94

OFF

ON

ON

ON

ON

OFF

ON

OFF

95

ON

ON

ON

ON

ON

OFF

ON

OFF

96

OFF

OFF

OFF

OFF

OFF

ON

ON

OFF

97

ON

OFF

OFF

OFF

OFF

ON

ON

OFF

98

OFF

ON

OFF

OFF

OFF

ON

ON

OFF

99

ON

ON

OFF

OFF

OFF

ON

ON

OFF

100

OFF

OFF

ON

OFF

OFF

ON

ON

OFF

101

ON

OFF

ON

OFF

OFF

ON

ON

OFF

102

OFF

ON

ON

OFF

OFF

ON

ON

OFF

103

ON

ON

ON

OFF

OFF

ON

ON

OFF

104

OFF

OFF

OFF

ON

OFF

ON

ON

OFF

105

ON

OFF

OFF

ON

OFF

ON

ON

OFF

106

OFF

ON

OFF

ON

OFF

ON

ON

OFF

107

ON

ON

OFF

ON

OFF

ON

ON

OFF

108

OFF

OFF

ON

ON

OFF

ON

ON

OFF

109

ON

OFF

ON

ON

OFF

ON

ON

OFF

110

OFF

ON

ON

ON

OFF

ON

ON

OFF

111

ON

ON

ON

ON

OFF

ON

ON

OFF

112

OFF

OFF

OFF

OFF

ON

ON

ON

OFF

113

ON

OFF

OFF

OFF

ON

ON

ON

OFF

114

OFF

ON

OFF

OFF

ON

ON

ON

OFF

115

ON

ON

OFF

OFF

ON

ON

ON

OFF

116

OFF

OFF

ON

OFF

ON

ON

ON

OFF

Continued on next page

18

Pelco Manual C1487M-C (7/99)

Image 18
Contents Listed Contents List of Illustrations List of TablesImportant Safeguards and Warnings GeneralMeasures DE Securite Importantes Dome Drive IN-CEILING ModelsBack Box Lower DomePendant Models Pendant ComponentsSpectra II Pendant Components DescriptionModels Spectra II IN-CEILING ComponentsSpectra Lite IN-CEILING Components Installation for IN-CEILING ModelsSpectra Lite Pendant Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsControl Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationAuto Flip POWER-UP DisplayPAN and Tilt Functions Scan SpeedPreset Functions Zoom Spectra II ZoomSpectra Lite Zoom Zones AlarmsRANDOM, FRAME, and Auto Scanning PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite Main Menu Access Backlight CompensationReset Camera Zoom LimitDenotes items that apply to the Spectra II only AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Alarms not starting a pattern Symptom Fan does not operateSymptom Alarms not going to preset Symptom Motion problemsMaintenance Back BOX Electronic Assembly RemovalDome Cleaning Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices