Pelco c1487-c operation manual Alarm Pattern, Zone Blank

Page 39

NOTE: Pattern length is set on the secondary menu en- titled Other.

NOTE: To make the pattern run to its end when an alarm activates it, make alarm dwell time longer than pat- tern length. Therefore, if the alarm goes away before the end of the pattern, the pat- tern will continue until the dwell times out.

ALARM PATTERN

(This section applies to Spectra II™ only.)

In response to an alarm, the Spectra II™ dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3 minutes long). You can choose one of the following for each of the seven alarm inputs:

Full Pat (run full pattern)

Half Pat 1 (run half pattern 1)

Half Pat 2 (run half pattern 2)

No Pattern

To change the alarm pattern:

1.Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section). The main menu will appear.

2.If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to position the cursor beside Alarms, Zone Blank.

3.Press the Iris Open button to enter the Alarms, Zone Blank submenu.

4.Move the joystick up or down to position the cursor beside Alarm Pattern.

5.Press the Iris Open button to enter the Alarm Pattern submenu.

6.Move the joystick up or down to position the cursor beside the number of the alarm input for which you want to set the pattern.

7.Press the Iris Open button. The cursor will move to the right beside the words Full Pat, Half Pat 1, Half Pat 2, or No Pattern.

8.Move the joystick up or down to toggle between the choices.

9.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

ZONE BLANK

(This section applies to Spectra II™ only.)

This feature lets you define any of eight zones as blanked for video when the camera pans into the zone area. The choices are On and Off. On means video blanking is in effect. The default is Off.

To change the blank zone setting:

1.Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section). The main menu will appear.

2.If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to position the cursor beside Alarms, Zone Blank.

3.Press the Iris Open button to enter the Alarms, Zone Blank submenu.

4.Move the joystick up or down to position the cursor beside Zone Blank.

5.Press the Iris Open button to enter the Zone Blank submenu.

6.Move the joystick up or down to position the cursor beside the number of the zone for which you want to set the blank option.

7.Press the Iris Open button. The cursor will move to the right beside the word On or Off.

8.Move the joystick up or down to toggle between the words On and Off.

9.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

Pelco Manual C1487M-C (7/99)

39

Image 39
Contents Listed Contents List of Tables List of IllustrationsImportant Safeguards and Warnings GeneralMeasures DE Securite Importantes Lower Dome IN-CEILING ModelsBack Box Dome DrivePendant Components Pendant ModelsSpectra II IN-CEILING Components DescriptionModels Spectra II Pendant ComponentsCeiling and Back BOX Preparation Installation for IN-CEILING ModelsSpectra Lite Pendant Components Spectra Lite IN-CEILING ComponentsSuspended Ceiling Installing Back BoxWiring Diagram for Spectra WiringRG6/U Cable Type Maximum DistanceTable B VAC Wiring Distances Back BOX InstallationBack BOX Connections From controller To 4-Wire terminal on circuit boardControl Dome Drive Switch Locations Table C. Switch Settings for SW1For D-type control systems, refer to Table E Baud Rate Switch Setting SW2-6 SW2-7 SW2-8For P-type control systems, refer to Table D 100 117 177 Lower Dome Lower Dome Installation, In-Ceiling ModelsPENDANT-MOUNT Installation Installation for Pendant ModelsOperation SURFACE-MOUNT InstallationScan Speed POWER-UP DisplayPAN and Tilt Functions Auto FlipPreset Functions Zoom Spectra II ZoomSpectra Lite Zoom Patterns AlarmsRANDOM, FRAME, and Auto Scanning ZonesPark Auxiliary OutputsProgramming the Spectra II and Spectra Lite Backlight Compensation Main Menu AccessReset Camera Zoom LimitDenotes items that apply to the Spectra II only GAIN/AGC AGC ModeAuto Iris GainShutter Speed Sharpness AUTO-FOCUS ModeLine Synchronization White Balance Color Cameras onlyPOWER-UP Mode Alarm Resume AUX ModeAlarm Priority Alarm DwellZone Blank Alarm PatternProportional PAN Turning Limit Stops On or Off Limit StopsPattern Length Park Time MinutesSymptom Unit does not operate TroubleshootingSymptom Motion problems Symptom Fan does not operateSymptom Alarms not going to preset Symptom Alarms not starting a patternMaintenance Back BOX Electronic Assembly RemovalDome Cleaning Mechanical SpecificationsSD5 Series Dimension Drawing Ntsc EIA Regulatory Notices Warranty and Return Information