Pelco c1487-c operation manual Symptom Fan does not operate, Symptom Alarms not going to preset

Page 44

d.Turn on power. If the unit still does not operate, turn off power and replace the dome drive with a unit that is good, if you have a spare. Check the switch settings on the substitute dome drive before installing it. If you do not have a spare, return the dome drive to the factory. Also return the back box electronic assembly. Refer to the Back Box Electronic Assembly Removal section.

e.If you substituted a dome drive, turn on power. If the unit operates, the original dome drive is bad. Return it to the factory. If the unit still does not operate, then the interconnect board is bad. Return the back box electronic assembly to the factory; refer to the Back Box Electronic Assembly Removal section.

Symptom: Fan does not operate.

1.Turn off power.

2.Remove the lower dome:

In-Ceiling Models - Insert the flat blade of a screwdriver into one of the slots on the trim ring and twist the screwdriver to pop loose the trim ring and lower dome.

Pendant Models - Remove the two screws that hold the trim ring to the back box. Insert the flat blade of a screwdriver into the slots on the trim ring and twist the screwdriver to free the lower dome from the back box.

3.Remove the dome drive: Push in on the green drive eject tab on the side of the dome drive and gently rock the dome drive to release the latch. When the green latch releases, pull the dome down.

4.Make sure the connector for the fan is fully seated.

5.Replace the dome drive. Turn on power. If the fan does not operate, return the back box electronic assembly and dome drive to the factory for repair. Refer to the Back Box Electronic Assembly Removal section.

Symptom: Alarms not cycling when more than one alarm is active

Reset all your alarm priorities to all LOW or all HIGH (refer to the Alarms section for an explanation of alarm high/low priorities). To reset the alarm priorities, do the following:

1.Go to the Main Menu Access section and follow the instructions for accessing the programming main menu.

2.Go to the Alarm Priority section and follow the instructions for setting the alarm priority.

Symptom: Alarms not going to preset

1.Check that the preset is defined.

2.Check that no higher priority alarm is activated.

3.Check that a pattern is not set for the affected alarm(s). If a pattern is set, the alarm will run a pattern, not go to a preset. If a pattern (or patterns) is set, reset the pattern(s) to NO PATTERN.

To reset a pattern, do the following:

1.Go to the Main Menu Access section and follow the instructions for accessing the programming main menu.

2.Go to the Alarm Pattern section and follow the instructions for setting the alarm pattern.

Symptom: Alarms not starting a pattern

Ensure that the pattern selected is valid. Any time you expect a pattern to execute, make sure the pattern is recorded correctly and is valid.

Symptom: Motion problems

When troubleshooting motion problems on a system where alarms are connected, you can eliminate alarms as a cause of the problem by disconnecting the alarm block in the back box.

44

Pelco Manual C1487M-C (7/99)

Image 44
Contents Listed Contents List of Illustrations List of TablesMeasures DE Securite Importantes Important Safeguards and WarningsGeneral IN-CEILING Models Back BoxDome Drive Lower DomePendant Models Pendant ComponentsDescription ModelsSpectra II Pendant Components Spectra II IN-CEILING ComponentsInstallation for IN-CEILING Models Spectra Lite Pendant ComponentsSpectra Lite IN-CEILING Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsControl Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationPOWER-UP Display PAN and Tilt FunctionsAuto Flip Scan SpeedSpectra Lite Zoom Preset FunctionsZoom Spectra II Zoom Alarms RANDOM, FRAME, and Auto ScanningZones PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite Main Menu Access Backlight CompensationDenotes items that apply to the Spectra II only Reset CameraZoom Limit AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Fan does not operate Symptom Alarms not going to presetSymptom Alarms not starting a pattern Symptom Motion problemsDome Cleaning MaintenanceBack BOX Electronic Assembly Removal Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices