6.Move the joystick up or down to toggle between On or Off.

7.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

ALARM DWELL

(This section applies to Spectra II™ only.)

This is the minimum time the Spectra II™ will stay at an alarm even if the alarm is present for less than this amount of time.

To change the alarm dwell:

1.Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section). The main menu will appear.

2.If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to position the cursor beside Alarms, Zone Blank.

3.Press the Iris Open button to enter the Alarms, Zone Blank submenu.

4.Move the joystick up or down to position the cursor beside Alarm Dwell sec.

5.Press the Iris Open button. The cursor will move to the right beside the number of seconds for the alarm dwell time.

6.Move the joystick up or down and hold to cycle through 1-200 seconds in one-second increments.

7.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

ALARM PRIORITY

(This section applies to Spectra II™ only.)

This feature lets you set alarm inputs as either high or low priority. A high priority alarm will not release to a low priority alarm. Alarms will release or sequence between low priority alarms only if no high priority alarm exists. (Refer to the Alarms section for more informa- tion.)

To change alarm priority:

1.Program preset 95 (28 if in 32-preset mode; refer to the Preset Functions section) to access the main menu (refer to the Main Menu Access section). The main menu will appear.

2.If the cursor (>) is not beside Alarms, Zone Blank, move the joystick up or down to position the cursor beside Alarms, Zone Blank.

3.Press the Iris Open button to enter the Alarms, Zone Blank submenu.

4.Move the joystick up or down to position the cursor beside Alarm Priority.

5.Press the Iris Open button to enter the Alarm Priority submenu.

6.Move the joystick up or down to position the cursor beside the number of the alarm input for which you want to set the priority.

7.Press the Iris Open button. The cursor will move to the right beside the word High or Low.

8.Move the joystick up or down to toggle between the words High and Low.

9.SELECT - Press the Iris Open button on your keyboard to select your choice. CANCEL - Press the Iris Close button if you do not want to change the setting.

38

Pelco Manual C1487M-C (7/99)

Image 38
Contents Listed Contents List of Illustrations List of TablesMeasures DE Securite Importantes Important Safeguards and WarningsGeneral Dome Drive IN-CEILING ModelsBack Box Lower DomePendant Models Pendant ComponentsSpectra II Pendant Components DescriptionModels Spectra II IN-CEILING ComponentsSpectra Lite IN-CEILING Components Installation for IN-CEILING ModelsSpectra Lite Pendant Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsControl Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationAuto Flip POWER-UP DisplayPAN and Tilt Functions Scan SpeedSpectra Lite Zoom Preset FunctionsZoom Spectra II Zoom Zones AlarmsRANDOM, FRAME, and Auto Scanning PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite Main Menu Access Backlight CompensationDenotes items that apply to the Spectra II only Reset CameraZoom Limit AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Alarms not starting a pattern Symptom Fan does not operateSymptom Alarms not going to preset Symptom Motion problemsDome Cleaning MaintenanceBack BOX Electronic Assembly Removal Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices