Pelco c1487-c operation manual RANDOM, FRAME, and Auto Scanning, Zones, Patterns, Alarms

Page 26

RANDOM, FRAME, AND AUTO SCANNING

Program preset 97 (30) to start random scanning. Program preset 98 (31) to activate frame scanning (three seconds of scanning followed by a three-second pause). Program preset 99 (32) to start auto (continuous) scanning.

Scan limit stops are controlled by software. Refer to the Limit Stops section to program the scan limit stops.

When the dome reaches a scan limit stop, it will immediately reverse direction.

Program preset 96 (29) to stop a scan. Any pan/tilt or lens command also will stop a scan.

ZONES

(This section applies to Spectra II™ only.)

The Spectra II™ dome is capable of eight zones, each with a 20-character label. Depend- ing on the controller, you can define the zone size and define any zone as “blanked” for video when the camera pans into the zone area. If zone labels are turned off, the system displays the message VIDEO BLANK to indicate the video is being blanked and is not failing. (Refer to the Zone Blank section for instructions.) For other information on program- ming zones, refer to the documentation for your control system.

PATTERNS

NOTE: Changing the length erases all stored patterns.

(This section applies to Spectra II™ only.)

The Spectra II™ dome can do either one full pattern (1.5, 3, or 6 minutes long) or two half patterns (.75, 1.5, or 3 minutes long). This pattern can consist of any standard pan and tilt or lens command. Presets, flip, and turbo are not allowed in a pattern. Zone scan can be enabled while running a pattern.

Refer to the documentation for your control system to program and run patterns.

ALARMS

(This section applies to Spectra II™ only.)

The Spectra II™ dome has seven alarm inputs, which can be designated as either high or low priority through its programming menu. When an alarm is received, the dome does one of the following:

Moves to the preset position that corresponds to the alarm number. For example, if alarm 3 is activated, the dome moves to preset 3.

Runs a half pattern or full pattern as programmed in the Alarm Pattern submenu.

If any of presets 1-7 are not used for alarms, they can be used as regular presets. However, if they are being used for alarms, they should not be used for anything else.

If an alarm input is programmed to run a pattern, the corresponding preset can be used as a regular preset. For example, if alarm 3 is programmed to run a pattern, preset 3 can be used as a regular preset.

There is no indication at the controller that an alarm has been received, other than the view displayed on the monitor.

The high priority setting (if set on the programming menu) is significant when more than one alarm is activated. If priority in alarms is not required, leave all alarms in the low setting.

If the activated alarm inputs have the same priority–all low or all high–then the dome will sequence between the presets that correspond to the alarm numbers.

If the activated alarm inputs have different priorities–for example, one is high and four are low–the dome goes only to the high. It remains fixed on the high and only goes to the low after the high has been cleared.

26

Pelco Manual C1487M-C (7/99)

Image 26
Contents Listed Contents List of Illustrations List of TablesMeasures DE Securite Importantes Important Safeguards and WarningsGeneral Dome Drive IN-CEILING ModelsBack Box Lower DomePendant Models Pendant ComponentsSpectra II Pendant Components DescriptionModels Spectra II IN-CEILING ComponentsSpectra Lite IN-CEILING Components Installation for IN-CEILING ModelsSpectra Lite Pendant Components Ceiling and Back BOX PreparationInstalling Back Box Suspended CeilingWiring Wiring Diagram for SpectraCable Type Maximum Distance RG6/UBack BOX Installation Table B VAC Wiring DistancesFrom controller To 4-Wire terminal on circuit board Back BOX ConnectionsControl Switch Locations Table C. Switch Settings for SW1 Dome DriveBaud Rate Switch Setting SW2-6 SW2-7 SW2-8 For D-type control systems, refer to Table EFor P-type control systems, refer to Table D 100 117 177 Lower Dome Installation, In-Ceiling Models Lower DomeInstallation for Pendant Models PENDANT-MOUNT InstallationSURFACE-MOUNT Installation OperationAuto Flip POWER-UP DisplayPAN and Tilt Functions Scan SpeedSpectra Lite Zoom Preset FunctionsZoom Spectra II Zoom Zones AlarmsRANDOM, FRAME, and Auto Scanning PatternsAuxiliary Outputs ParkProgramming the Spectra II and Spectra Lite Main Menu Access Backlight CompensationDenotes items that apply to the Spectra II only Reset CameraZoom Limit AGC Mode GAIN/AGCGain Auto IrisShutter Speed AUTO-FOCUS Mode SharpnessWhite Balance Color Cameras only Line SynchronizationPOWER-UP Mode AUX Mode Alarm ResumeAlarm Dwell Alarm PriorityAlarm Pattern Zone BlankProportional PAN Limit Stops Turning Limit Stops On or OffPark Time Minutes Pattern LengthTroubleshooting Symptom Unit does not operateSymptom Alarms not starting a pattern Symptom Fan does not operateSymptom Alarms not going to preset Symptom Motion problemsDome Cleaning MaintenanceBack BOX Electronic Assembly Removal Specifications MechanicalSD5 Series Dimension Drawing Ntsc EIA Warranty and Return Information Regulatory Notices