VICTORY II VHS Models
An automatic air vent is used to remove air from the sys- tem. It should be installed in the top of the boiler as shown in Figure 15. If system pressure needs further control, add an additional tank in parallel with original tank or install a larger capacity tank. Use appropriate size tank for volume of water in system. See chart for boiler’s volume.
Boiler Water Content
Model | Pounds | Gallons |
|
|
|
17.5 | 2.1 | |
24.75 | 3.0 | |
32.00 | 3.8 | |
39.25 | 4.7 | |
46.50 | 5.6 | |
53.75 | 6.4 | |
|
|
|
4.Cold Water Fill
Pressure reducing (fill) valve and
5.Relief Valve Discharge Piping
Use same size or larger piping than valve outlet. Must ter- minate 6" minimum from floor with a plain (no threads) end. Place a bucket under pressure relief valve discharge. Make sure discharge is always visible. DO NOT
6.Providing Protection from Freezing
7.Water Treatment
A good water treatment program will not only extend the useful life of this boiler but it will also save much of the time and expense of repairs made necessary by pre- ventable occurrences. A reputable water treatment compa- ny should be consulted to evaluate and determine the best overall treatment program for your boiler equipment.
PIPING A HEATING - COOLING SYSTEM TO A WATER BOILER AND CHILLER
Figure 16 illustrates a method of piping a heating-cooling sys- tem to a water boiler and a chiller. Hand valves (shown) or automatic valves must be installed to prevent circulation of chilled water in the boiler or hot water in the chiller.
The air control system and pressure control system must operate with chiller only, or the boiler only, being valved to the piping system. Separate control devices on the boiler and chiller may be used, or a single set of air and pressure con- trols on the common piping may be preferred.
If the boiler is used to supply hot water to heating coils in air handling units, flow control valves or other devices must be installed to prevent gravity circulation of water in the coils dur- ing the cooling cycle.
Figure 16.
OPERATING INSTRUCTIONS, BASIC
1.Filling and Venting Water Systems
A.Fill the system with water. Vent or purge of air.
B.Fire the boiler as soon as possible (see following warn- ing and instructions) and bring water temperature in the system.
C.Vent air and add water as needed to achieve operating pressure on boiler gauge. Pressure must be between approximately 12 psi (cold water) and 25 psi at water temperature setting of high limit control, for boilers equipped with 30 psi relief valves. Boilers rated for a higher pressure and equipped with a matching relief valve may operate at a higher pressure, but no higher than 5 psi below the relief valve opening pressure.
D.Check for and repair any leaks before placing system in service.
BEFORE FIRING BOILER, make these checks:
1.System is full of water. Air is vented or purged.
2.Relief valve is installed in accordance with ASME Boil- er and Pressure Vessel Code, Section IV. Valve open- ing is not closed or reduced in size.
3.Venting is installed according to instructions under
“FLUE GAS VENTING REQUIREMENTS”.
4.All wiring is completed, following applicable wiring dia- grams.
5.Using soap solution, check for gas leaks in all gas pip- ing from meter to boiler pilot and manifold. DO NOT use open flame.
2.Initial Start
Safe lighting and other performance criteria were met when testing various gas manifold and control assemblies used on the Victory II Series Boilers under the ANSI Z21.13- latest edition.